Browse By Tags

  • Converting between SUDA and Legacy Geopak

    Current Version: Power GEOPAK V8i (SS10) I am in the process of starting a new drainage design and am trying to determine the most efficient workflow in order to provide the following: - 2D Drainage Layout - Inlet and Pipe Computations - Drainage…
  • Wsparcie dla aplikacji V8i po 31 grudnia 2021 r.

    Zgodnie z naszymi zasadami pomocy technicznej dla aplikacji komputerowych , wsparcie dla aplikacji Bentley V8i SELECTseries 10 zostało zakończone z dniem 1 stycznia 2022 r. Równocześnie, zakończyło to wsparcia dla wszystkich wersji V8i oraz wcześniejszych…
  • Equal Space Points tool issue

    I'm attempting to place a series of 2D points using the Equal Space Points tool and upon doing so, keep receiving the "Element off design plane" error message immediately followed by the all too common program crash. I noticed it created a 3D model in…
  • Supporto per le applicazioni V8i SELECTseries 10 dopo il 31 dicembre 2021

    Supporto per le applicazioni V8i SELECTseries 10 dopo il 31 dicembre 2021 In base alla nostra politica di supporto per le applicazioni desktop Supporto per applicazione desktop , il supporto per le applicazioni Bentley V8i SELECTseries 10 sarà interrotto…
  • Advanced Map Finishing

    Bentley Map V8i provides Map Finishing tools which were formerly available in a product called CADscript. To access the Map Finishing tools in Bentley Map V8i, initialize your DGN in the msgeo_mapfinishing workspace. The following is a tool comparison…
  • Support for V8i applications after December 31st, 2021

    As per our support policy for desktop applications , support for Bentley V8i SELECTseries 10 applications will be discontinued as of January 01, 2022, concluding support discontinuation for all V8i and earlier generation versions. Those applications…
  • Earthwork Quantities - Fill and Unsuitables

    I am removing 4" of topsoil was able to get it to show up in my cross section using the Unsuitable section in the End Area Volume Tool. However, when the fill is being calculated in this tool, it is not covering all of the area that is the unsuitable…
  • MicroStation V8i (SELECTseries 10) Freigabe für speedikon V8i 08.11.12.38

    Speedikon V8i 08.11.12.38 ist jetzt zusätzlich zertifiziert auf MicroStation V8i (SELECTseries 10) bzw. MicroStation PowerDraft V8i (SELECTseries 10) in deutscher bzw. englischer Sprache. Die empfohlene Versionsnummer ist 08.11.09.931. Die MicroStation…
  • OS Could not load .dll, error 126.

    Hello, I have a custom add-in for Microstation Select Series 4. I had this .dll working before in my older dev machine. Then, I upgraded to SS10 and I was still able to run my custom add-in. However, I got a brand new machine. Proceeded to do a clean…