• Import ProSteel DWG funktioniert nicht
      Produkt(e): ProSteel 3D Professional           Version(en): CONNECT Edition   Umgebung: Windows   Produktbereich: Allgemein Problem

    Nach dem Öffnen einer ProSteel DWG ist nur eine 2D Ansicht da und ProSteel Objekte fehlen.

    Problemlösung... Read more.
  • License Issues - Finding the Correct System

    GeoStudio currently supports different licensing systems, which typically are defined either the first time the application opens or by going to the user profile in the top right corner of the GeoStudio window and selecting 'Change License System'. The...

    Read more.
  • suggested an answer to this:
    HS Model - default stiffness parameters - reason

    Dear all,

    I've searched and didn't find anything regarding the default settings for the stiffness parameters in the hardening soil model.

    By default E_50 =E_oed and E_ur=3 E_50 is set. From my understanding, both conditions do not apply to every...

    Read more.
  • suggested an answer to this:
    Lateral water loads not acting on PLATE above ground level

    Hello, I am trying to model two different water levels on each side of a plate. The plate extends above ground surface. The water levels are also above ground level. However, PLAXIS is not showing any lateral load from the water acting on the plate above...

    Read more.
  • suggested an answer to this:
    Two surface loads on the same surface

    Hi,

    When I was applying surface loads to surfaces, I found that only one surface load is allowed on the same surface. I would like to know how to apply two different forms of loads on the same surface as shown in the following figure.

  • replied to this:
    做门的时候开孔位置的位置有二个或者更多,为什么做成CELL剪切不了墙体

    做门的时候开孔位置的位置有二个或者更多,为什么做成CELL剪切不了墙体  后是没有显示构筑,红箭头是做了二个开孔机

  • suggested an answer to this:
    Reference Settings Not Saving with Save Settings

    I want to be able to leave my .dgn and not have reference settings save. In v8i I could toggle on "save settings to save changes" and toggle off "save settings on exit" under preferences. In MicroStation Connect I don't seem to have that option in my preferences...

    Read more.
  • replied to this:
    [ps c++] 刷新钢筋问题

      

    这个是删除钢筋的方法,但是删除完之后点刷新钢筋 又重新出现了原来已经删除的钢筋这种问题要怎么解决?

  • suggested an answer to this:
    SACS SQlite did not produce data for JointCanSummaryUC, etc

    Hello everyone,

    I would like to ask if there are anyone know about my sqlite database did have data on certain tables after the analysis? is there any option or anything that trigger data not being produced?

    Thank you in advance!!!

  • suggested an answer to this:
    Register Oracle Spatial feature with leadered annotation

    Hi specialist,

    According to geo_example.xml, feature should be able to add annotation with leader line.  However, it cannot post the leader line to Oracle spatial.  Bentley Map (old version) should be able to post leader line to DB.  I wonder what steps...

    Read more.
  • **ERROR: THE RAYLEIGH FREQUENCY 3.02972E-06 IS LESS THAN 0.00001 FOR LOAD 1

    **ERROR: THE RAYLEIGH FREQUENCY 3.02972E-06 IS LESS THAN 0.00001 FOR LOAD 1

    PCI SHED.STD

    Read more.
  • replied to this:
    iTwins Visualisation for PowerBI

    Hi all,
    Just curious if the iTwins Visualisation for PowerBI is available to be used at all?
    I saw Bentley had the Data Connectors available to be used and it would be great to link the queried data with the iModels

  • replied to this:
    Input Parameter of Tie Rod?

    The Input Parameters for the Tie Rod in Plaxis-2D-Unit Weight & Axial Stiffness (EA), where E is the modulus of Steel - 210 GPa and area depends on the diameter of the Tie Rod. But how to input the Grade of Steel? Because different steel grade has different...

    Read more.
  • Missing Data

    Here you will find an explanation and best practices for solving Missing Data related synchronization errors.  

    Category: Missing Data

    Missing data errors are a common issue in Synchronization. Understanding the missing data errors requires a knowledge of what...

    Read more.
  • Missing Community on SMC

    Product:

    Assetwise ALIM

     

    Version(s):

    All

    Environment:

    N/A

    Area:

    N/A

    Subarea:

    N/A

     

     

    Problem :

    User lost or deleted there Community from the SMC

    Solution:

    If the Community existed previously and was lost or deleted...

    Read more.
  • Rise and fall of pressure graph

    I would like to ask in what problem does my model occur? a weird pressure  graph happening in time 10:00-20:00. please see the graph Thank you

  • replied to this:
    Sub sea pipeline

    Dear sir,

            How to model anchors at the two ends of a pipe to fix it on the sea bed ?

           

  • replied to this:
    Importing 3d Materials for Synchro 4d

    Hello, 

    I found one post that was helpful which has different kind of equipment that we can import to Synchro 4d pro however I could not find anything related to materials such soil, concrete...etc, It makes no sense to have animated excavator which is...

    Read more.
  • replied to this:
    com interface

    Exploring methods for background automation in STAAD.Pro via its COM interface, aiming to execute tasks without launching the graphical interface; seeking advice, examples, or references from the community.

  • suggested an answer to this:
    Funcion de Open Staad para extraer tabla "Participation Factors" del Staad Pro y reescribirla en Excel con Visual Basic

    Hola,

    Estoy programando con VBA utilizando las funciones de Open Staad pero no consigo la manera de extraer la tabla "Participation Factors" para copiarla en Excel, ¿Cuá sería la funcion de Open Staad para realizar esta copia de datos?...

    Read more.