Grateful if someone can help me. I've just purchased Multiframe version 21. I've tried it on 3 separate monitors and changed the Windows display settings but all that does is change the text font size, it doesn't increase the size of the toolbars/ icons...
Read more.I have a similar issue with Multiframe 2023 (23.07.00.268) running on Win 11 (home). I can get Multiframe to look okay using the scaling on high DPI under properties and compatability - except on the plot scren where the plot image remains small and not...
Read more.【问题描述】
在Import Utilities/Import InRoads导入.sdb文件时,可能产生下面的错误


【分析原因】
如果计算机上安装的 Microsoft Access Database Engine (ADE) 组件版本出现问题,就会出现此错误。因为OpenRoads Designer是需要64-bit AccessDatabase Engine配合使用的,所以如果电脑中没有安装该版本的ADE就会出现错误。
【解决方法】
从下面的网址下载安装64位的ADE
Read more.I am modeling opposite beams to column web in RAM Connection. I noticed when I put the opposite beam, it does not appear in the monitor. RAM is not showing the opposite beam. How to rectify this?
Regards,
Nicolas
Hi Nicolas,
For Eurocode, for simple connections, we follow the procedure suggested by the SCI in the Joints in Steel Contruction Simple Joints to Eurocode 3 (Publication P358).

For your concerns, you might check Example 1 p.38 where the Bolt group capacity...
Read more.Hi Carlos,
Sorry for replying late. Anyway, thanks a lot for the reply and explanation. Hoping for adding the enhancement in the next version.
Regards,
Nicolas
Hi
when I selected the resource group was selected, I notice that only parent level resources were selected. This will become a problematic in viewing the progress using resource status in 3D view after assign resource status by resource group. Is this...
Read more.在OpenRoads Designer(10.12.02.4)中,在把参考文件合并到主文件的时候,有时候会发生参考文件中的某些层丢失的现象。下面我们就来看一下具体的现象:
首先我们创建一个DGN文件作为参考文件。并创建Test.Level层,在该层绘制圆形。然后创建LevelABC层,并在该层上绘制矩形。

我们再次创建一个主文件,将参考文件参考进来。这个时候观察圆形和矩形都分别位于参考文件相对应的层上面。


接下来,我们把参考文件合并到主文件后,再观察两个图形元素所在的层。
我们不难看出...
Read more.
Rock Bolts are under the Confinement Group inside the Construction Tab in the Ribbon Main Menu, as shown below.

Just note that the model in your project must be already using a Tunnel Catalog/Template with Tagged Elements as Rock Bolts to define the region...
Read more.甲方要求提供广州2000坐标系的三维模型及高程成果。Google后发现坐标系的转换比较复杂,想请教一下要满足甲方要求需要从哪方面入手?要解决什么问题?具体流程如何?万分感谢!
有广州坐标系的Wkt或PRJ文件么?
没有,这两个数据需要怎么获取?我们有用RTK测量控制点,不知能RTK中导出?
老师们好,我改写了DrawingComposotion中的一个函数,将两个DPoint3dP和一个int类型作为输入,返回类型为int。现在在尝试将这个函数封装为可供.net调用的dll。
编译时,SDK提示如题错误。我的目标是将两个点传入来计算剖切volume的生成范围。
请问有什么办法支持DPoint3dP类型的入参吗?如果不能支持,通常以什么方式传入点呢?
DPoint3d是c/c++类型,在c#端是没办法调用的,需要将参数改为Bentley.GeometryNET.DPoint3d
按此方法可以成功编译。在C#中,只需要使用unsafe,将.NET的DPoint3d的指针作为参数传入即可。论坛不支持选自己的回复作为最终答案,之前的回复被吞掉了。
This article will provide an overview of Leica Total Stations added via a Thread connection.
Yes, been here before. Branding (or assignment to workset) caused the DGN file to change it's modified date even if nothing was done other than opening. I use the modified date, it's good information for me. When this happened the first time, back in...
Read more.ProjectWise has it's own issues with file modified dates & times. Any time you copy a file in ProjectWise, or drag a file into ProjectWise the file updated entry is changed to the current date/time even though the file itself didn't change. Makes finding...
Read more.Hi Bob,
Thanks for your post. I'm sorry to hear about your frustrations.
When you refer to the "modified date", I'm assuming you are referring to something like the Windows File Explorer "Date Modified" column? 
-Jayson
I am designing a mat slab foundation beneath a series of concrete shearwalls using ram concept. At the corner of the mat slab, an excessive amount of program reinforcement is being specified, and in looking at the section analysis, is due to a very large...
Read more.I saw your file in the uploads. Did you notice the warnings in the calc log: "ERROR: An error has occurred: Seismic(EQ_ASCE716_X_+E_F) has horizontal loads, but the structure is automatically stabilized in the X and Y directions."
You should...
Read more.PS, in the Modeler, the Mat Foundation properties were applied multiple times, overlapping. This leads to some complexity in the Concept meshing that's not really needed. You could delete all the applied concrete decks are reapply just one application...
Read more.If anyone know how to create model of PC cable inside concrete box girder in OpenBridge Modeler (without linking with RM Bridge), please give me some advices or instruction to do it.
Thank you.
Hi Tola, at this moment the only way to define tendons in OBM is through out RM Bridge. But you can always try to use MS 3D tools available in OBM to generate cables as solids. You can try to create one solid extruded along a path, as an exmple.
Hi Ana Carla Peres,
Thank you for your answer.
As you say, I agree that the only way and the better one is to define tendons in RM Bridge. But right now, I want to try modeling cables in box girder using only the tools in OBM in order to understand the...
Non-SELECT契約のマシン(デバイス名)登録について
SELECT契約の1 つの特典として、任意のPCでも利用できるようライセンスプールができることです。Non-SELECT契約の場合、永久ライセンスは、1 台のPCに対し 1 人のユーザーに製品使用資格が与えられます。以前はこのノード ロック制限は、特定のマシン用に生成されたライセンス...
Read more.Howdy! I have an issue where upon trying an export for a simple dgn file to fbx or obj, the files some out with nothing in them. At least, zero vertices or anything of the sort. It is exporting something - the levels used are converted to groups in the...
Read more.In version 8, Fit Selection has been added to PokeIt.

The installation instructions are provided in the included PDF file.
Read more.According to the user guide, I should be able to create a new project from the system ribbon in OpenGround Cloud Professional. However, those options are missing for me. How can I view them?
They have assigned the project creation role, but I still do not have the project creation option when I launch openground. Is there anything else we should check?
Hi
I have the same problem
I had this problem too. There is a fix for this. This seems to be a DPI issue. Here is what you need to do.
1) Press Windows Logo key + R to open a Run. Type in regedit and press Enter.
2) In the left pane of the Registry Editor, navigate to the following directory...
Read more.