Dear Friends, after performing spectral EQ analysis and combine gravity with EQ as per below post file the Posview is showing deferent UCs and it's not considering the 1.7 modifier.
OPTIONS MN SDUBJO 5 5 DC C PTPTPT PT
UCPART 0.7000.7001.0001.0001000...
Hello Ahmad Sanad
After running the Spectral earthquake combination analysis, you need to run a post-processing analysis,

And in this step, you need to create a preprocessing file in which you request the creation of a postvue, This is where you can add...
Read more.In MicroStation V8i I used the find/replace text tool all of the time. I especially used on Bill Of Material when I had to put in lengths of reinforcing steel. I would copy and paste text from Excel files. The reinforcing steel would always copy in (i...
Read more.Hi Barry,
Just left a message for you.
In your file you have a space before the "-" and a tab after the "-". In CONNECT version as a "space" and a "tab" are different characters, the program does not recognize the tab as a space when...
Read more.
Hello,
I know I can Displayset Set the chosen solids to achieve isolation, But I wonder if I can hide only the selected solids.
Thanks,
Amya
Thanks,Dilip.And, I'm sorry I wasn't able to explain the situation.
It's as you guessed, but the position accuracy of the model is very high, so the pier is directly modeled in OBM.
This does not appear in the Explorer window.
If it is not an OBM element, then hopefully you have each component in a unique level and you could turn the desired levels ON/OFF.
For version 23.00.00.### - Expected September 2023
New and updated feature summary
This section lists the new and updated features that are available in ADINA System 23.0.0, as compared with ADINA System 9.10.0.
There are...
Read more.Good afternoon Forum!
On Microstation 2023, there is a recurring issue when I simply pan or zoom for a bit on the dgn file and all of the sudden the PC freezes on me. So much that I have to do a force restart. The dgn's I work with are in ProjectWise...
Read more.There might be requirement for the users where they need to create Custom Part...
Read more.We are actually using Open Roads, but this is not specific to Open Roads. On my PC, my initial screen offers the Manage Configuration button/menu. But on a few other users, there is no option to manage configurations. I looked at the variable MS_CONFIGURATIONOPTS...
Read more.I am relatively new to 3d modeling in Microstation.
Question
I see pop-up info is on for my object (e.g. cylinder, level = 1, etc.). Can this information in the pop-up be edited (i.e. include particular information such as color, size, etc.)?
If not, is...
Read more.you cannot change the information provided in the pop-up native in the application. You can get either the auto-popup info at your cursor when hovering over an element, or you can move your cursor over the element in question, hold Alt+Reset (right-click...
Read more.Thank you for the information.

I wanted to change the orientation of Local X and Y axes in plate without changing the Local z axis. (All plates should be rotated 90 degrees or 270 degrees w.r.t Local z)
So that the outcome should be look like the below image.

I am using a 3dDConnexion mouse to pan and zoom in and out in Microsation Connect update 17. I am getting a flickering only in the work area on my screen when I pan. Is there a way to smooth that out?
It's like the frame rate is set really low so I have...
Read more.Could just be weak graphics card.
Maybe, but I do not have very complex files most are around 1 MB with very few that are more. My two monitors are only 1440p. I have no trouble in SketchUp or anywhere else on the system. I feel like I have a setting somewhere that I just need to adjust...
Read more.Hi,
The SETPOINT and CONCEN soureTypes are quite bugged in the latest version of WaterGEMS and CAD (10.04.00.108).
So far I had been able to function with workarounds to the bugs but now I've encountered a point I can't figure out a workaround for. I...
Read more.I have a test model I created to test MSX code and impact of tank mixing on chlorine/chloramine decay, it's a bit of a mess but should be understandable. I've uploaded this using the secure file upload to save you time replicating these bugs.
Please...
Thank for providing the model. We are looking into this and will be in touch when we have more information.
Regards,
Scott
Problem
Moje bezbarwne/nieistniejące tło tekstu podświetla się jako szare w wersji OpenRoads/ Site/ Rail Designer 10.12. Podświetla się na szaro w...
Read more.Hi everyone,
I am trying to import a tif file to an ORD file. But the program categorically refuses to do so?
I tried with files that have defined and undefined coordinates, 2D and 3D but nothing seems to work.
Does anyone have any suggestions?
PS I...
Read more.hello,
I would submit to support so that they can have a look if there is a bug or limitation regarding the size of the tif, or an issue with th etif itself.
I just tested with an old tif 3 millions points and it did work perfectly in few seconds.
To activate the feature definition, we use the toolbar

When placing geometry like a line or complex pi, the active feature is selected, which corresponds to the toolbar choice.

Using the key-in GEOMETRY SETACTIVEFEATURE Linear \pad\featurename allows...
Read more.Ensure that the THREAD is turned on and that the Flowav is connected to the Thread via one of the Thread Device ports.
1. Navigate to the Connectivity Module.

2. Press the
button directly on a THREAD to add a Device to it. If your TH...
Importing from Primavera can be achieved via P6 XML file or directly from the P6 database using the P6 API. Direct database access can be achieved for either PPM or EPPM (Standalone/Local or Server) versions of Primavera P6.
Note: For any assistance with...
Read more.When I put tank at the end to fill it in 24 hours or 2 days, I always get the negative pressure at the Junction just before the tank, no matter how much head i put at the pump, the junction always shows the negative pressure, please guide me how can I...
Read more.My tank Maximum water surface elevation is 135.25 and my source is reservoir and I have to check that how much the tank will be filled in 24 hours, I am using pump after reservoir with 30m head, but pump is operating only at 8m head. Reservoir elevation...
Read more.The pump will operate at the point where the pump curve intersects the system head curve per this article. So, if the pump is adding less head than you expect and it is pumping from a reservoir to a tank, this would suggest that the friction losses in...
Read more.Rejoignez-nous pour découvrir les dernières améliorations introduites dans la mise à jour 44.
Entre les nouveautés, nous allons :
Parcourir les différence du Tema 10th
Expliquer les nouveautés des berceaux: dimensions...
Hello Ricardo,
Yes, its CSF for seismic combined with gravity. below is the dynpac input.
********************** PROJECT NO. xxxxxxxx ********************************
Read more.*********** EARTHQUAKE EQUIVALENT STATIC LOADS GENERATION ******************
DROPT...