• Current-Latest Version of each Document

    The three key documents for AssetWise Enterprise Interoperability are

    • the per-release read me announcements
    • the setup guide
    • the interop overview white paper

    To reach the most recent version of each, you can use these links (current as of November 2023...

    Read more.
  • Accumulated Readme files

    Each release has a stand-alone read-me file. Here are links to all of them, so that you can more-easily review the changes from multiple releases. 

    Each link opens the file-download page in a new window. 

    Note: last updated November 2023.

    From most recent...

    Read more.
  • Release 1.2.46.0
  • PDF
    AssetWise Enterprise Interoperability Readme for v01.02.46.01

    New features and release notes for AWEIS version 01.02.46.01.

  • How often is the Change Log getting updated with the 2023 releases - https://communities.bentley.com/products/3d_imaging_and_point_cloud_software/w/wiki/54568/changelog---contextcapture. I'm looking for more details on the latest 23.00.03.501 available

    How often is the Change Log getting updated with the 2023 releases - communities.bentley.com/.../changelog---contextcapture. I'm looking for more details on the latest 23.00.03.501 available from Software Downloads as well as prior releases?

  • [ORD2022R3] How do I find the "Hidden" elements that Civil Ruled elements depend on?

    When you have two tangents, cut an arc between them and trim both, the original elements are still there, but set to "hidden".  P_BL in my case below:

    P_BL2 in this case was 'created' during the trim command of adding in the curve.

    ... Read more.
  • replied to this:
    Suitable solver for Analysis of Check-Dams/Weir for Trapezoidal Channel

    Hi Everyone,

    I am in search of a case study that focuses on trapezoidal channels with check dams. The study should introduce Check Dams at specific intervals based on the model settings that are best suitable to introduce weir configuration as alternatives...

    Read more.
  • replied to this:
    Painfully Slow Print Organizer

    Hello,

    We have been developing Print Organizer usage for the past 2 years to make way for Batch Plotting to no longer be available to us in future versions of Microstation. In both Select Series 10 and Connect Edition 16 the PO is unbelievably slow. Always...

    Read more.
  • General Steel Design Solutions

          Applies To        Product(s): STAAD.Pro   Version(s): All   Environment:  N/A   Area:  Steel Design   Subarea:  General Steel Design Solutions   Original Author: Bentley Technical Support Group    

    This page contains solut...

    Read more.
  • edited this:
    Why does the critical load case, along with the design forces/moments, change when I turn the slenderness check off and on?

          Applies To        Product(s): STAAD.Pro   Version(s): All   Environment:  N/A   Area:  Steel Design Codes   Subarea:  AISC   Original Author: Bentley Technical Support Group    

    Why does the critical load case, along with the...

    Read more.
  • suggested an answer to this:
    How to model a thickened edge sidewalk in Open Roads designer

    Hello Community, 

    I'm fairly new to design and I have encounter this project where I am require to add a Thickened edge sidewalk. However, I do not know how to add this to my template. below is a picture of a detail I found.

    does anyone has experience...

    Read more.
  • replied to this:
    Whether is there a way to extract data from element assembly

    When I import ifc to synchro I cannot find data that was from Element Assembly. is there way workaround to get the data?

  • Dialogs are not visible or will not open

    Product: 

    OpenRoad SignCAD 2023

    Version: 

    23.00.00.151

    Area: 

    Troubleshooting

    Original Author: 

    Bentley Global Technical Support 

    Problem:

    Dialogs are not visible or will not open when using OpenRoads SignCAD.

    Solution:

    1) If...

    Read more.
  • suggested an answer to this:
    Draw graph

    To draw graph between load vs settlement after deformation. I know that uy has to be considered for settlement , then for load what have to consider ?

  • suggested an answer to this:
    Borehole Navigator in SS10

    We are trying to import a .csv file into the Borehole Navigator in “Legacy” Microstation SS10, and we are receiving the following error / information message below, “No Borehole Name Was Provided”

    The screen capture below indicates...

    Read more.
  • STAAD Foundation Advanced New

    STAAD Foundation Advanced 20xx is the next generation software to the current STAAD Foundation Advanced V9 and represents a significant advancement in the software offerings from Bentley Systems, Inc. for the modeling and design of reinforced concrete...

    Read more.
  • replied to this:
    OPEN ROADS PRINT ORGANIZER WILL NOT PLOT SHEETS CORRECTLY BUT CTRL P WILL.

    Hello,

    I've been using the print organizer to print my sheets and things were working fine for weeks.

    I have multiple reference files that now have updated/new linework and the print organizer won't print the new linework but they do show up when...

    Read more.
  • replied to this:
    OpenRoads Designer - Working Cross Section Set

    Has anyone come up with an efficient way to compile a single DGN file with cross sections in OpenRoads Designer? Currently, we are referencing all of the XS models into a nested compiled file, which is tedious and inefficient. I submitted a product enhancement...

    Read more.
  • replied to this:
    asked a question in OpenRail > OpenRail Forum:
    Modeling Templates for Turnouts/Diverging Tracks

    I'm trying to make a template for a diverging track. I want the ballast section of the diverging one to start as widening the mainline ballast section, then when it gets far enough away,  to have its own separate ballast section

    I have the toe of...

    Read more.
  • suggested an answer to this:
    negative pressure in junction near a one way surge tank.

    There is a negative pressure in junction near a one way surge tank. How can it be if the volume of the tank is larger than the effective volume discharged to the pipeline? Thank You.