Looking for a script to calculate the ratio of each IJ cell to OD total of N number of ODs. The output matrix is same in size
OD1 OD2 10 20 7 5 5 9 11 18 44 41 Output1 Output2 0.12 0.24 0.08 0.06 0.06 0... Read more.Looking for a script to calculate the ratio of each IJ cell to OD total of N number of ODs. The output matrix is same in size
OD1 OD2 10 20 7 5 5 9 11 18 44 41 Output1 Output2 0.12 0.24 0.08 0.06 0.06 0... Read more.I have attached some iTwin models to my dgn, but have no control on nesting. Seems it only displays in active file? Not very useful when trying to cut a plan or when viewing master model federations.
Hi Duncan,
Hope you are well!
We did some further digging into this issue and it looks like a bug to us. So, I will file a new Case on your behalf and will report the same to our Dev team for further investigation.
Regards,
Sayan
Hi,
I am exporting RAM SS to ISM to import it into Revit. I no longer am getting the mapping dialogue pop up when I sync, but columns are not set to split upon exporting.
How do I get mapping dialogue back?
Also, some of the columns are still being...
Read more.The column splicing is different for gravity and lateral columns. If you are not seeing the ISM options dialog when pushing, then you might have to push to a new repository.
Hi all,
Does anyone know or know of a document outlining the procedure to create new instrument lines and connect them to the schema? I've created the line styles in the PID_LineStyles_ANSI.rsc and new entries in the PID schema under the Instrument...
Read more.Hello Cameron, you may follow this wiki. OPPID - How to modify/add Instrument lines
Let me know if this helps.
Hi, does anyone know the command to drop the actual steel beams from the automated steel stairs? I tried drop element but doesn't seem to do it I want to modify the steel channel for a connection.
Hi Diane,
Thanks for letting us know about this.
We will have some discussion regarding this and will let you know. Meanwhile if you have a sample DGN file can you please provide us for further testing?
Regards,
Sayan
Sure where do you want me to send it
Hello, in hydropneumatic tank modeling shall we keep selecting true for the “treat as Junction” during the transient calculations, and in this case is water hammer software will treat the tank as hydro pneumatic tank regardless to our previous selection...
Read more.Purpose
Bentley’s Earned Value Discount (EVD) offers you the opportunity to save with three discounts components: volume, version, and the E365 Subscription. This report allows you to check your EVD status and see how it was calculated.
Roles
Users...
Read more.Hello everyone,
I was wondering if it's possible to display a mesh as a pattern/hatch. (see the image below for reference)

Thanks in advance.
PS : I'm using OpenRoads Designer 2022 R1
Hello everybody.
To solve another problem, I used the latest version of SewerGEMS software to work on my project, as I intended to do 2D simulations. However, as it is a feature that is not available for summer students (unfortunately), it ended up...
Read more.Hi Jesse,
I managed to make the transformations. However, for the channel elements, I didn't find how to do the transformations from conduits. I noticed that the conduits are configured as trapezoidal type, would this configure an open channel?
... Read more.You can right click on a conduit and choose the option to morph into a pressure pipe, but the option to morph to a channel is not available because channels expect cross section nodes at the endpoints (see more here). So, you may need to manually lay...
Read more.Share Sync allows you to synchronize files from ProjectWise Share to your computer. Using Share Sync you can upload files to ProjectWise Share for project members to access, or you can access files that have been uploaded to ProjectWise Share by project...
Read more.After running update Synchro 4D Pro 6.5.1.5 equipement nog longer follow a 3D path. Equipement remains stationary at its original position during the task. Adjusting the alignement path (Tak properties -> 3D path -> alignement) also has no effect. Is...
Read more.Hi Edwin,
This may be a project-specific bug. I would suggest reaching out SYNCHRO Support for further review. Please send over the v6.5 SP file, and if available v6.4 as well.
Thanks!
Read more.Any update on this matter? I am experiencing the same problems here
Hi all, I want to run tow fatigue analysis with hull deflection case with PERSET command line in SACS, but when I try to run the analysis, it shown an error without any explanation. Could anyone provide any advice how to run the tow fatigue analysis with...
Read more.Hi Renaldo,
There is some information on PERSET in this article, but if that does not help, please provide more details on the error (screenshot, message details, log file, etc)
STRUCTURAL ANALYSIS WITH STAAD. PRO Virtual Internship (Cohort-6)

Structural Engineering and Analysis – Project Based Learning
This Internship entails completion of the following:
1) 2 Self-paced learning modules.
CONNECT Edition 10.11.++
Environment: Windows 10/11 (64-bit) Area: Export Subarea: iModels Original Author: Joseph Gelacio, Bentley Techinical Support G... Read more.
CONNECT Edition 10.11.++
Environment: Windows 10/11 (64-bit) Area: Element Subarea: Original Author: Nikitesh Kawana, Bentley Global Technical SupportIn order to change order...
Read more.for shown attached snap Iam designing a walkway for a tank and I want to check torsion in the curved highlighted beam, Iam using direct analysis method, should I consider (Lx=2.405) design parameter for highlighted beam or no need to use Lx, Ly & Lz in...
Read more.Is there any guide or explanation for TND parameter (video tutorial would be great) and for my case what number should I choose for a curved beam released at its ends at equal spacings, when I choosed (4) cause my ends are pinned and distributed torque...
Read more.I am not aware of any tutorials related to this. I think that you should consider the curved beam in the same way as straight pinned member and assign the TND parameter based on the torsional load type applied to it. These loading conditions are explained...
Read more.The following WIKI articles are provided as a reference by Bentley's Technical Support Group. They focus on the OpenRoads SignCAD CONNECT Edition product.
Read more.Hello iTwin,
I'm very proud to upload an original Revit file to iTwin to use it in OpenBuilding. So I don't have to ask IFC files. My clients are mostly Revit users. Is it possible to create some converter in iTwin to make RVT files. Maybe for future...
Read more.How would I know the Cancel Button was pressed in the dialog displayed via the Show-PWFolderBrowserDialog cmdlet if an Initial Folder Path is provided or the user has browsed to a folder? Currently it appears the path is returned regardless of which button...
Read more.I am getting version 23.2.5 when I run the installation. I get the same results in the 32 and 64 bit versions of PowerShell.
Did you have a folder selected or define the initial Folder Path with -InitialFolderPath as shown below? I get the same results...
Read more.Using the InitialFolderPath parameter I am able to reproduce the problem. It is in the queue to be fixed.
Mark Weisman | Bentley Systems
Hi Duncan,
Thanks for the detailed information.
Let us have some testing regarding this and will let you know about our findings.
Regards,
Sayan