I just have 2D survey drawing AutoCAD and i want to model it in 3D using OpenRoads Designer. pls help
I just have 2D survey drawing AutoCAD and i want to model it in 3D using OpenRoads Designer. pls help
Hello,
When I inactivate an inlet pipe in my system and run the model, I get the error message "tank references a deleted or inactivated inlet pipe". I want to ensure that my tank can supply the distribution system using only the elevation head (no help...
Hi Derek,
You can temporarily change the property Has Separate Inlet? on the tank to false, then it won't try to validate the referenced Inlet Pipe.
Hope this helps and that I have not misunderstood the issue.
Regards,
Wayne.
I want to establish a circular retaining structure with a buried depth of 1.5m, so in phase 1, I deactivated the soil with a diameter of 10m and activated the circular retaining structure. I can understand the uplift of the soil inside the enclosure structure...
Read more.Hi,
Do you mean that the upward movement of the concrete structure causes the upward movement of the surrounding soil? But in my model, I'm not putting any force on the concrete structure. I do not believe that the concrete structure can move upward due...
Read more.Maybe in reality it can't, but if you modelled the soil using for instance the Mohr-Coulomb model it can because you assume soil to be linear elastic. So often this problem can be avoided by choosing a better model for the soil (HSsmall, for instance...
Read more.Wie kann man im DetailCenter einen eigenen Standard für Detailstile anlegen.
ProblemlösungEs macht Sinn...
Read more.Hi Bentley Community,
Recently I have come across a project that required me to use EC3 to design for cold form structure.
From Staad software, I realised we do have european table for cold formed section and only EN1993-1-1:2005 for my design checking...
Read more.EN1993-1-3 is not implemented in STAAD.Pro, so the design of cold formed sections is not supported in STAAD.Pro as per Eurocode. An idea to implement this code into STAAD.Pro is already logged in our IDEAS porta: Cold formed Member design to EN 1993-1...
Read more.Hi, I am using OpenRail Designer CE 2021 R2. I wanted to know if OpenRail has extended capabilities such as automation with the help of VBA or any other method. I just want to start looking into this direction with simple tasks such as reading the alignment...
Read more.Hi JP, as you rightly pointed out it is for OpenRoads, due to license costs I cannot use both software simultaneously, moreover OpenRail is more suited for Railway design so it makes sense to stick with it as the capabilities will grow even more in future...
Read more.There is SDK for OpenRail. It is the one for OpenRoads. OpenRoads SDK includes Rail as well. It is bit confusing, but it is there.
User had a ODC Service set-up to point to an OPC compliant data historian on a different network...
Read more.Online Data Collection indicator readings are not being collected.
SolutionOpen the Settings Editor for the server instance...
Read more.The below information will take you through the updates that are specific to this application. For more general information and product update videos, please see the general New Release page.
v10.0.1.1821
Released 5th October 2023
The below information will take you through the updates that are specific to this application. For more general information and product update videos, please see the general New Release page.
v10.0.1.1983
Released 5th October 2023
The below information will take you through the updates that are specific to this application. For more general information and product update videos, please see the general New Release page.
v10.0.1.1983
Released 5th October 2023
Hi,
in 23.00.01.44 I tested this data source (INSPIRE theme Cadastral Parcels published by ČUZK).
When I tried to query data, I received this error:

I treat it as bug, because if I remember correctly, I was able to use the same service in other software...
Read more.Hello Jan
Even I tried connecting to the URL having Cadastral Parcels data. I can connect to the server and also see 3 features under it. But, as you mentioned, when we try to query, it gives the error message as shown by you. I have reported it as a...
Read more.


I am creating 3 files in projectwise named as MOC,MOD & DRG
In MOC, I attach one survey file (Railway tracks, structures etc) as reference which is provided by client with 1:1 scale nad live nesting as 3.
In MOD, I attach MOC as reference with 1:1 scale...
Read more.Hi,
I have a error pop up when i have just finished building the model. do you have any idea how to resolve it?
I attached the screen capture for your inforamtion.

Thanks
Regards,
Brian
Hi Sayan
Yes exactly.
Regards,
Brian
Hello Brian,
Can you please provide us screengrabs of the model before and after changing orientation if possible?
Regards,
Sayan
Hi,
I have a question regarding catenary plot. From all the sample given, the catenary plot is for static condition. Is it possible to produce catenary at max tension when running 3 hrs simulation and obtain the value of line on seabed during the specific...
Read more.Hi Naim,
The CAT_PLOT command does exactly that. You can plot the catenary for a range of tensions using the -tension option. To get the line at the bottom, you have two options:
1.) You can enter the CONFORCE command inside the PRCPOST menu and plot the...
Read more.Hello Everyone,
I wanted to enquire about possibility of creating a web link/ Cloud model link for the 4D simulation created in Synchro 4D Pro. What the client wants is to be able to zoom, pan or move anywhere in 3D view along with timeline attached...
Read more.Hi
I've created some properties in an Item Type and these properties uses expresssion.
Example:
prop->SetExpression(L"this.GetElement().TotalLength");
When attaching the Item Type to an element (manually or via code) the property value...
Read more.Hi all,
I've managed to figure out the reason for my problems not being able to set the accuracy. I just had to set the type of the property do double..
Regards,
Evan
Hi there,
You may send over the file to identify how 2D elements are in the dwg. I have done this before in MXROAD converting 2D text to 3D points.