参考学习以前的帖子,想根据两个点打断ComplexStringElement,使用了ClosestPointBounded获取了两点对应的CurveLocationDetail,但是CurveLocationDetail中只能得到两个点在ComplexStringElement中所在部分的正确fraction,而得不到点在ComplexStringElement中所在部分的index值,请问复杂串的打断是否可以采用这种方法?
参考学习以前的帖子,想根据两个点打断ComplexStringElement,使用了ClosestPointBounded获取了两点对应的CurveLocationDetail,但是CurveLocationDetail中只能得到两个点在ComplexStringElement中所在部分的正确fraction,而得不到点在ComplexStringElement中所在部分的index值,请问复杂串的打断是否可以采用这种方法?
5657.BLOCK - B (1) E2.stdStaad analyis and design tab closing abruptly and concrete design is not performed for all columns. Please see. i am using latest staad pro connect edition.
Read more.This issue is addressed in the most recent STAAD.Pro 2023 (version 23.00.01.25) so upgrading to it should help.
Patients at the Mayo Clinic may view their health data via an interactive website called the Patient Portal. Appointments and medication refills may also be requested by patients. The patient portal was developed to facilitate self-management of medical...
Read more.Hello everyone,
I create a rigid body and assign a soil material to it. The rigid body has been activated for the calculation. I wondered what is the difference between between activating or deactivating the soil material within the rigid body while the...
Read more.Hello Lanting,
A rigid body has its boundary conditions there, either displacements or forces at its reference point. So, it has these interaction with material within it there.
I think it is good that you just run two models with activating and deactivating...
Hi,
How do I model a solar PV structure mounted on a house roof? Where can I find the tool in Staad Pro?
hello Surojit, if you already developed the sheet kindly share with us
Dear Sir:
I am using STAAD.Pro for my term project. However, while going through it I doesn't found any options which let me define the material nonlinearity behavior for Nonlinear time history analysis. Hence, I want to know whether the STAAD.Pro provides...
Read more.STAAD.Pro does not consider material nonlinearity. ADINA is another Bentley offer which can do this: ADINA - RAM | STAAD | ADINA Wiki - RAM | STAAD | ADINA - Bentley Communities
Hello iTwin Capture Community,
I hope this message finds you all in good health. I am writing to seek technical assistance regarding an issue I am encountering in iTwin Capture Modeler. Specifically, I am experiencing difficulties in accurately modeling...
Read more.You have to use some sort of geometry constraints when reconstructing water surfaces.
As water is reflective, images from different angles will reflect the sun and the sky differently and so the AT process can't find good tie points to use.
Personally...
Read more.
两个实体求差集获得元素的层级结构,为什么不一致呢
手动操作的结果

调用SolidUtil::Modify::BooleanSubtract 的结果,变成了smart solid

工具操作的结果是参数化实体,SolidUtil操作的结果是智能实体。
要想和工具结果相同,需要调用SmartDFeature相关的API。
好的,感谢老师的回答
Applies To
Product(s):
STAAD.Pro
Version(s):
ALL
Environment:
ALL
Area:
STAAD.Pro Support Solutions
Subarea:
Connection Design workflow
Original Author:
Abhisek Mandal, Bentley Technical Support...
Read more.
Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: STAAD.Pro Support Solutions Subarea: Connection Design workflow Original Author: Abhisek Mandal, Bentley Technical Support Group ... Read more.8546.THESIS-09-15-2023-2.std
please help me fix the warnings and notes , Im just sick today. I have uploaded the file. Thank you
Read more.There are multiple PERFORM ANALYSIS command in the model. You need to keep one PERFORM ANALYSIS command. Please refer to-
**WARNING-A MOVING LOAD THAT WOULD HAVE BEEN APPLIED BEYOND THE X AND Z RANGES
Can't open Modeler file when I change to Medium Stations on Section Calculation.
SolutionAttempting to load higher station and precision may result...
Read more.Please provide a LIST of the updates implemented in STAAD to go from AISC 360-10 to AISC 360-16
AISC 360-10 and 360-16 both versions are available in the program. You may refer help file below location to know the implementation of AISC 360-16 in details.
Home > Design > D. Design Codes > D1. American Codes > D1.A. American Codes - Steel Design...
Read more.Please either attach tge file or insert the link
Im having trouble adding a containment list to single part plate details via detail centre express. Is there an explanation for this somewhere so i can check the settings required?
Alternatively can a list be created via the Partlist Creation command...
Read more.Hi, I am writing a code that analyzes properties of all the elements in a DgnFile and compare the compliancy of those properties with some project-specific standards.
For Mesh Elements, I want to retrieve the Civil Quantities data but I couldnt find any...
Read more.Hi Benjamin,
I recommend to move your post to Civil Programming forum. You can do it using More > Move tool, available Under your original post.
Also, please share simple test case. Civil data are complex and can be created and srtuctured in different...
Read more.For Mesh Elements, I want to retrieve the Civil Quantities data but I couldnt find any ways to access those properties.
Civil objects are complex structures, so often it requires to do analysis what data is stored where. Some preperties...
Read more.
老师,你好,根据安老师提取XY值的方法成功提取X、Y,但是Z值要怎么提取,这个Z值是在第二个逗号和引号之间,现在就是这个第二个逗号怎么表示。以下是取Y值的表达式 System.String.Substring(this["RangeLow"],System.String.IndexOf(this["RangeLow"],",")+1,System.String.LastIndexOf(this["RangeLow"],",")-1-System.String.IndexOf(this["RangeLow...
您好,需要有您这个Item的DGN文件发上来,我这里看看能找到对应的方法不,谢谢。
Hi,
I asked before if it is possible to create color coded elevation in ORD. It was suggested to use the Display Style as Thematic.Height, which works quite good, but in PowerCivil I was also able to export the file as a dwg. I wonder if there is another...
Read more.Bumping this topic as it is relevant to what I am doing, I don't believe there is a tool that will create coloured shapes so that we can dumb it down and not have it linked to a triangulation. This will certainly help when exporting a DGN or DWG.
... Read more.Unfortunately not at the moment, there is an idea to add this functionality, you can vote here: microstation.ideas.aha.io/.../MSR-I-935
您好,模型太大了,我给上传网盘了,麻烦了
链接:https://pan.baidu.com/s/1R59j7cgJHhwnsJ4MPhAr6A 提取码:y579


您好!目前程序不支持梅花型锚杆的创建。
下面变通的方法可以试试:
复制当前模型文件,创建新的锚杆,然后把含新锚杆的文件参考进原文件。关闭其他对象图层,仅显示参考文件里面的锚杆。
也可以把参考文件合并到主文件,为了只合并锚杆,可以在参考文件里锁定其他对象的图层。合并后的锚杆是智能实体。
如果需要计量的话,需要回到参考文件进行。
注意做好备份。
------------------------------------------------------------------------------...
Read more.
Dear Abhisek M,
Facing similar issue in STAAD Connect Edition V22 Update 12. How to resolve this.
Thaks in advance.