I want to use strength reduction method to calculate the safety factor of slope after earthquake, but the safety calculation procedure is not allowed after dynamic calculation in PLAxis 2D software. May I ask how to solve this problem?
Why should the factor of safety after a dynamics calculation not be different from the factor of safety in the static case? It would make sense if they were different since the stress state is probably different.
With kind regards,
Dennis Waterman
Hi, I'd like to create a task filter based on downstream total float, but I can't seem to find it withing the filters categories nor user fields, is this not a supported filtering feature?
Also, could I clarify what data is going to be displayed...
Read more.hi Rafael,
We can copy the downstream total float to a user field. and can do taks filter from this user field.
You can use this User Field Formula.
STRING_DURATION( PROPERTY("Downstream Total Float") , CALENDAR)

Best regards,
Indrawan
Thanks Indra
Hi,
I would like to get origin coordinates for selected cell. There is PropertyHandler with AccessString named 'Origin' that can be used to get what I want. The problem is that the value I'm received using GetDisplayString looks like "1.000m; 5.000m;...
Read more.Oops, you are right, I did not realized (did it in a hurry) the properties does not from the cell itself.
Regards,
Jan
That's ok, I'll just stay with the way around solution:)
Dear Synchro 4D Pro Support Team,
I am writing to seek assistance with using the script feature in Synchro 4D Pro. I am encountering difficulties in utilizing the script functionality and would appreciate your guidance in resolving this issue.
I have...
Read more.hi Indrawan
IT"S work thank alot
can you tell me how yto avoid this problem for the other scripts
Regards,
karim
hi Karim,
The script will be case by case.
Just let us know if you have other script that not working.
Regards,
Indrawan
Hello Everyone,
My target is to create Cross Sections file with points (from point cloud) in Autocad format.
I completed the below steps.
Hi,
I'm modelling a network and I'm getting very low pressures on the rising main( from Tank 1 to Tank 2) I have 2 PS on the raising main, from the second pump to the end of the rising main( Tank) there is a huge elevation difference and the low pressures...
Read more.Hello Ana,
I tried working on your model and found that the nodes near the tanks are at nearly the same elevation as the water level in the tank. it will be difficult to get at least 1 bar pressure at this junction. If you check the pressure zone manager...
Read more.Hello Everyone,
My target is to create Cross Sections file with points (from point cloud) in Autocad format.
I completed the below steps.
如下图所示的功能是否存在c++或者c#的接口呢?我尝试使用宏录制,但是在VBA中使用SendKeyin来调用。请问有没有对应的接口?

Hi
The following error appears in sewergems update -3 is there any help i can not make compute for the model

Thanks
Hello Sayed,
This issue may be related to licensing. First, ensure that a feature level is selected in the Feature Level Selector and that the Bentley Licensing Tool shows that the product is activated.
If there is indeed a problem with the license status...
Read more.您好,我们正在调查您的问题,如有更新会及时和您联络。谢谢。
总体思路:给其中一条边线套用组件模板,用点控制让组件的另外一侧点随着另外一条边线走。
对于组件,顶面要有3个点,两边线点和路中线点,中线点的约束由两边线点控制。所以当廊道模型建立完成后,路线中心线也就确定了。
The crack detector that I could find from the download page is for the photo segmentation. I tried using this one for the same dataset and it did detect the cracks. My main question is which detector can be used to detect crack for point cloud data ?
... Read more.Hi! I would like to ask about the RC designer. I am designing a slab and after clicking design, there are different labels in the column Min. Steel. Either the label would be Y, n and Fail. Can you explain what does Y, n, and Fail means?

RC Designer is available only in STAAD.Pro V8i, which is not supported anymore. You can still use it though, just we don't provide support to it.
may I still know what's the meaning of Y and n? is it a yes or no? or Yes and Neutral? I really need this :((

This is the book "PRINCIPLES OF STRUCTURAL ANALYSIS -STATIC AND DYNAMIC LOADS" by Krishnan sathia, which is launched on bentley institute press,
Regarding this book,
As in the description there is written "it contains dynamic properties of...
Read more.1. Only linear time history is covered in this book. This book is specific to STAAD.Pro, so it does not cover any topic from other applications like ADINA.
2. No, manual calculations are not covered here.
Kindly suggest any text book/reference book that covers linear and non linear time history analysis along with theory and manual calculations
Hi everyone,
I am making a model on Plaxis 20.2 for an embedded wall with steady state flow condition using a well. After the analysis, the flow direction of the water is from the side (like the first picture) instead of from the top (like the second...
Read more.Dear Dewangga,
If in the literature case there is no inflow or outflow through the sides, this means that the sides are considered to be closed flow boundaries. Hence, you would have to do that in your PLAXIS model as well. Whether that is realistic for...
Read more.


1. Already analyze Groundwater
2. Why cannot run slope stability and how I can solve this problem?
Dear Elijah,
Sorry to hear that you experienced an error with our software.
Since this seems to be a project-specific issue, please open a new Case for support. Then, one of our support engineers can help you in detail:
https://bentleysystems.service-now...
老师们好,我想为新建的Drawing Model和Sheet Model创建指向当前文件一3D模型中的一个自建PlanCallout的参考。
目前已创建了PlanCalloutDefPtr类型的Callout,如何通过它生成对应的NamedView供参考使用呢?
在DrawingComposition例子中使用了INamedViewCreateHelper,可否用于生成NamedView?
另外,按照郭老师给出的例子:
NamedView(SavedView)关联Clip - 技术资料库 - Bentley...
Read more.使用Callout也可以选择种子文件,您看这个例子里边另外那个创建SectionCallout的命令,是可以选择种子的。通过NamedBoundary可以实现任意方向的剖切。首先用来创建NamedBoundary的图形元素就圈中了一个范围,其次创建出来的NamedBoundary本身又有如下所示的属性:

这些属性控制了剪切的深度。通过NamedBoundary的GetElement属性可以返回一个元素,这个元素不是NamedBoundary那个图形元素,而是NamedBoundary本身这个元素...
Read more.好的郭老师,我再尝试一下。
the documentation here ( Log Only Functions ) doesn't provide a great explanation of the difference between "Aggregate" and "AggregateAll":
Read more.'Aggregate' performs an aggregation of the values for a single instance whereas 'AggregateAll...
Hi,
Within our data structure in ProjectWise, the parent folder represents a Business Unit and within this folder are the sub folders representing Projects (Work Areas). These Projects (Work Areas) are associated as CONNECTED projects. Hence; can we Associate...
Read more.Hi David, yes all the projects use the same environment/information structure. So we can associate the Business Unit to a connected project? Same process as for project?
Certainly! Leveraging ProjectWise's data structure with Business Units as parent folders and connected Projects as subfolders is a strategic approach. Associating the Business Unit parent folder would offer a consolidated perspective, enabling...
Bonjour,
Toutes les icones d'OpenRoads se ressemblent, et il peut être utile de distinguer les versions.
A cet effet, j'ai créé une icone pour la versions 2023.
Bonne journée !

Purée quelle bonne idée !! je l'avais déja fait pour la version d'avant, mais le tien est Top, je ne l'ai pas testé mais le fond est noir
Read more.Merci,
J'ai mis une copie d'écran du résultat, mais c'est le même .ico (fond transparent) avec le numéro, "Normalement" ;-)
Dear Dennis,
Thank You for your swift reply, but the Factor of Safety I am getting is slightly more during the phase of EarthQuake (1.272) than the Static case (1.260). Generally, This should not be the case. Can you please put some more light on this...
Read more.