• How to Move COG of a structure?
    Product(s): SACS Version(s): All Area: Precede

    Here are steps to be taken to change the position of calculated COG:

    Model 1

    1. After completing the model & loads, run a static analysis to check the COG of the structure.

    2. In the list...

    Read more.
  • earned the Discussion Starter I achievement.
    Discussion Starter I
  • and 14 others earned the Ask A Question I achievement.
    Ask A Question I
  • asked a question in MicroStation > MicroStation Forum:
    MicroStation 2023 - Download DWG/Civil3D 2023 Object Enablers

    Hi-

    As Autodesk has now moved the object enablers behind a paywall and we no longer have an active AutoCAD support agreement after moving to MicroStation, how do I download the Civil 3D 2023 object enablers to go with the RealDWG libraries in MicroStation...

    Read more.
  • Best Software to analyse slab supported by steel beams

    Hi,

    I have a 2 way slab with a lot of penetrations along a discontinuous edge. It is continuous in one direction (it spans over numerous steel beams). Slab is not composite (i.e. no shear studs in steel beam)

    Was wondering what the best analysis software...

    Read more.
  • test

  • earned the What If... achievement.
    What If...
  • How to create a standalone Substructure or Superstructure only model in OBD?

    Below are the steps to create a Substructure or Superstructure model:

    • Open OBD and open your OBDX file
    • As shown in the screenshot below:
      • Choose the Standalone workflow; by selecting Standalone, not the Default BIM Workflow,  at the top right of the Standalone...
    Read more.
  • No text in dialogs after WaterGEMS is integrated with Civil3D 2024
    Product(s): WaterGEMS Version(s): 2023 Area: Installation Problem:

    No text is seen in any dialogs after integrating WaterGEMS 2023 with Civil3D 2024.  

    Reference #1292663: Can't see text in dialogs after Integration with Civil3D

    Solution... Read more.
  • R3-8 Lane Control Sign

    Product: 

    OpenRoad SignCAD 2023

    Version: 

    23.00.00.151

    Area: 

    How-to

    Original Author: 

    Bentley Global Technical Support 

    Introduction:  The instructions below show how-to create a R3-8 lane control sign in OpenRoads SignCAD.

    The...

    Read more.
  • Version 23.2.7 of PWPS_DAB just posted to the PowerShell Gallery

    We just posted version 23.2.7 of the #PWPS_DAB #PowerShell module for #ProjectWise to the PowerShell Gallery.

    To install, from a 64-bit Admin session of PowerShell v5 run:

    [Net.ServicePointManager]::SecurityProtocol=[Net.SecurityProtocolType]::Tls12

    Uninstall...

    Read more.
  • Wrong percentage of mobile checksheet completion

    APM version 7.22, app version 2.5.1, Android.

    Hello all, we see sometimes a wrong percentage of checksheet completion when mobile app starts. As a result of this, inspectors can upload a checksheet which was not even started. Then it is not possible to...

    Read more.
  • Modifying inertia

    Within RAM Elements, how would it be possible to modify the inertia of a member?  For example, instead of using the inertia of a bare steel beam, I would like to use a more realistic inertia of a partially composite beam.  Using the inertia of a bare steel...

    Read more.
  • suggested an answer to this:
    RAM Connection - Proportion Loads Output

    The demand that is used in my gapped K-connection with square HSS design calculations is not the same as what I input into the program. This demand value that is used is from the generated proportional loads. Why are the proportional loads used instead...

    Read more.
  • Getting started with SYNCHRO
    How do you get started?

    Thank you for choosing SYNCHRO, the Top Constructech Product for two years in a row in 2022 and 2023 (Bentley Systems - Connected World). You have made the right choice. So how do you get started?

    First, let's make sure you have...

    Read more.
  • suggested an answer to this:
    GIS Pro 3.x Update for WaterGEMS

    When will this update be released?

  • Getting Started with Field

    Getting Started with the SYNCHRO Field App

    SYNCHRO Field is a robust application designed to streamline project management tasks on the job site and enhance collaborative efforts between SYNCHRO Control and SYNCHRO 4D. Follow these steps to begin harnessing...

    Read more.
  • Separating Steel beams/channels from automated Stairs

    Hi,  does anyone know the command to drop the actual steel beams from the automated steel stairs? I tried drop element but doesn't seem to do it   I want to modify the steel channel for a connection.

  • Beyond Centerline Geometry

    FIles needed for Training

  • replied to this:
    RAM Elements v16 update 8 won't open

    I have 2 users whose previously working RAM Elements all of a sudden throws an error when opening the program. The error is:

    bentley RAM Elements Access violation at address 00007FF832B91CC2 in module 'atio6axx.dll. 

    We have updated video drivers,...

    Read more.