I have to create multiple selection set after importing from GIS shape file in watergems model builder. So it is very time taking process for creating selection sets of no of zones are in more than 100.
Historically Access Database Engines (ADE) have been used OUS & Promis...
Read more.I'm trying to create a report that uses Groups and Aggregates. There are 2 properties grouped together, one is a Repair Type, and the other is an Item that is associated with the Repair Type. The Aggregate is the sum of the quantity of the item. The report...
Read more.Hi Austin,
Thanks for sharing dataset.
I have reported a bug for this issue.
Thanks,
Abhay
The time taken to load and change parametric cells is ridiculously slow. Is anyone aware of any tricks to speed this up?
I do, but I turn them off to test and doesn't make any appreciable difference.
Also a bit of a cop out from Bentley to say close this/close that, or have you reset prefs. Just make the dialogs work without lag.
Well, it definitely makes a difference if you have the properties window open when selecting a few hundred elements to e.g. move them. I don't know if that has any effect in your case, though.
I have data in GPJ format, and in HoleBASE, there is a 'gINT' option. However, I am unable to utilize the 'add' button. How can I convert the gINT file into HoleBASE?
Hallo zusammen,
ich habe heute folgende Email von Bentley erhalten:
Bentley - Benachrichtigung über befristete Lizenzen (MicroStation)
Benutzer (Benutzername) bei (Firmenname), hat am 1000.11.6 2023:7:40 eine befristete Lizenz für MicroStation ...
Read more.Hallo Herr Ziwitza,
die Bearbeitung Ihrer Anfrage wurde von mir übernommen.
Ich untersuche Ihren Fall und melde mich schnellstmöglich zurück.
Mit besten Grüßen
Jutta Kremer
您好,我在放置土木单元时不知道为何路面和人人行道会不在同一标高上,如下图所示:
,支路纵断面模型如下所示:
路面模板边线
已发您邮箱
您好,已经检查了您的视频。发现您没有给我提供另外两个参考文件。所以暂时没法复现您的问题。
初步怀疑下图所示路线高程的问题。

您好,模型里我已经放置了一排锚杆,我还想沿着隧道的外轮廓再放置锚杆,并且设置他的角度,请问可以实现吗?

Wie kann man die Zentrale für Benutzerteile im Workset integrieren?
ProblemlösungAm besten den Ordner...
Read more.I have to analyze and design a steel arch beam in Staad pro connect edition. I modelled a curved beam in elevation and applied all the loads on the beam that are to be transferred to the columns. The load pathway is working properly. However, when i look...
Read more.Yes, curved members in STAAD.Pro have many limitations as explained here: Limitations of the curved beams in STAAD.Pro - RAM | STAAD | ADINA Wiki - RAM | STAAD | ADINA - Bentley Communities
It is recommended to use a series of straight segments to model...
while working in user table section ,I am facing crash of software & getting notification like this attachment.



Getting these error notification. Can you please explain why this is happening & how to solve this.
Did you try to perform a clean installation as suggested by Abhisek? Didn't it help? What is the exact STAAD.Pro CE version being used?
Dear Sir/Madam,
With reference to above subject, Please provide some data or material regarding the modeling, analysis and design of retaining walls with anchors in staad pro software.
Thank you in Advance...
Regards
Maruthi Infrastr
Read more.You can model a retaining wall by using solids or plates while anchors could be modeled by using members. If retaining wall is modeled from plates, it can be designed in STAAD.Pro for bending moments only. If the wall is modeled from solids, you would...
Read more.Thank you for the reply...
各位老师,我放置了一个这样的带有下引线的批注元素,这个引线长度能否设置为固定长度?

您是想限制用户在操作或者修改这个引线元素时,无法修改它地长度么?例如只能移动或者旋转等,如果是的话,可能得考虑元素依赖来实现了,元素依赖就是往元素上添加一个属性,这个属性可以指定元素发生修改时,调用指定地函数,在函数中就可以将元素修改为指定长度。
元素依赖调用的这个指定函数是软件内置函数吗?
Hi Team,
For some reason i am able to assign Tension only and Truss Specification to the same members without any error. I am using STAAD 2023 and i have had no warning while doing the analysis.
Such warning should be reported in the Output file: WARNING: TENSION/COMPRESSION MEMBER IN MEMBER TRUSS COMMAND
If you are not getting it, please attach that model for the investigation.
How to model directly buried hot water pipes with AutoPIPE?
Solution:Start by modeling the piping arrangement...
Read more.使用的是Duplicate函数和DuplicateSingle函数,拷贝之前原来的元素有判空。

这个元素是用代码在实体上切出来的面,有时候运行良好,有时候崩溃,有时候陷入死循环
这一点代码根本看不出来哪里有问题,请提供一下更为详细的代码,最好是一段完整的可编译运行并能复现问题的函数,必要时请提供一下对应的测试dgn文件。这样可以更快速地帮您找出问题地原因来。
Trying to model 2D wave (carpet) spectrum in MOSES either from a forecast or measured data. Is there a software limit on the number of wave spectra (user defined from different directions) that can be applied at the same time, and can they each have their...
Read more.Hi John,
You can request this to be implemented in the MOSES Ideas portal here:
Regards,
Rahul Kanotra
Rahul, I will do this thanks.
Regards JD
Hi,
I would like to know if anyone here could help me how to get the value in Equipment and "Centerline Distance" from a Element placed through "Place Equipment" with a centerline as reference.
I would like to get the value through...
Read more.In the shared file, no Centerline Distance property is displayed:

Probably not crucial for general discussion how to access Equipment Data...
With regards,
Jan
Oh, i forgot that you also need the track-file that the element is attached to when placed.
230629_Test ORD Spår 1.dgn
How to model fluid / gas density in AutoPIPE?
Answer:
Using AutoPIPE V8i 09.06.xx.xx, a user can input the contents density value on the Pipe Properties dialog screen / Input grid:
Note: As mentioned in AutoPIPE...
Read more.
I'm actually using OpenRoads Designer version 10.10