• and 6 others earned the Ask A Question I achievement.
    Ask A Question I
  • Multiple selection set creation at the time importing from GIS based on Zones.

    I have to create multiple selection set after importing from GIS shape file in watergems model builder. So it is very time taking process for creating selection sets of no of zones are in more than 100.

  • Error message when Installing Promis.e CONNECT related to Microsoft Access or Microsoft Office 365
      Product(s): Promis.e CONNECT Edition   Version(s):  10.13.XX.XX through    Environment:  NA   Area:  Installation_Configuration    Subarea:  Installation Error

    Background:

    Historically Access Database Engines (ADE) have been used OUS & Promis...

    Read more.
  • suggested an answer to this:
    Sort Groups & Aggregates in Report

    I'm trying to create a report that uses Groups and Aggregates. There are 2 properties grouped together, one is a Repair Type, and the other is an Item that is associated with the Repair Type. The Aggregate is the sum of the quantity of the item. The report...

    Read more.
  • replied to this:
    Parametric cell speed

    The time taken to load and change parametric cells is ridiculously slow. Is anyone aware of any tricks to speed this up? 

  • gINT HoleBASESI and Openground

    I have data in GPJ format, and in HoleBASE, there is a 'gINT' option. However, I am unable to utilize the 'add' button. How can I convert the gINT file into HoleBASE?

  • replied to this:
    Term License for MicroStation

    Hallo zusammen,

    ich habe heute folgende Email von Bentley erhalten:

    Bentley - Benachrichtigung über befristete Lizenzen (MicroStation)

    Benutzer (Benutzername) bei (Firmenname), hat am 1000.11.6 2023:7:40 eine befristete Lizenz für MicroStation ...

    Read more.
  • suggested an answer to this:
    土木单元放置

    您好,我在放置土木单元时不知道为何路面和人人行道会不在同一标高上,如下图所示: ,支路纵断面模型如下所示: 路面模板边线

  • open tunnel放置锚杆的问题

    您好,模型里我已经放置了一排锚杆,我还想沿着隧道的外轮廓再放置锚杆,并且设置他的角度,请问可以实现吗?

  • Zentrale für Benutzerteile im Workset integrieren
      Produkt(e): ProSteel 3D Professional           Version(en): CONNECT Edition   Umgebung: Windows   Produktbereich: Allgemein Problem

    Wie kann man die Zentrale für Benutzerteile im Workset integrieren?

    Problemlösung

    Am besten den Ordner...

    Read more.
  • suggested an answer to this:
    Analysis and design of Arch Beam (Beams curved in elevation) in Staad Pro Connect edition.

    I have to analyze and design a steel arch beam in Staad pro connect edition. I modelled a curved beam in elevation and applied all the loads on the beam that are to be transferred to the columns. The load pathway is working properly. However, when i look...

    Read more.
  • replied to this:
    my staad select software is getting close again & again while working in user table section

    while working in user table section ,I am facing crash of software & getting notification like this attachment.

     

  • replied to this:
    How to Model Anchors for Retaining Walls in STAAD Pro?

    Dear Sir/Madam,

    With reference to above subject, Please provide some data or material regarding the modeling, analysis and design of retaining walls with anchors in staad pro software.

    Thank you in Advance...

    Regards

    Maruthi Infrastr

    Read more.
  • replied to this:
    [MS C++]带有下引线的批注元素能否将引线设置为固定长度?

    各位老师,我放置了一个这样的带有下引线的批注元素,这个引线长度能否设置为固定长度?

  • replied to this:
    Tension only and Truss Specification for same members.

    Hi Team,

    For some reason i am able to assign Tension only and Truss Specification to the same members without any error. I am using STAAD 2023 and i have had no warning while doing the analysis.

  • C.12. How to model directly buried hot water pipes with AutoPIPE?
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Modeling Date Logged
    & Current Version Nov 2023
    23.00.00.230 Problem:

    How to model directly buried hot water pipes with AutoPIPE? 

    Solution:

    Start by modeling the piping arrangement...

    Read more.
  • replied to this:
    【C++ PS 二次开发】元素拷贝老是崩溃或者陷入死循环

    使用的是Duplicate函数和DuplicateSingle函数,拷贝之前原来的元素有判空。

    这个元素是用代码在实体上切出来的面,有时候运行良好,有时候崩溃,有时候陷入死循环

  • replied to this:
    2d wave spectra

    Trying to model 2D wave (carpet) spectrum in MOSES either from a forecast or measured data. Is there a software limit on the number of wave spectra (user defined from different directions) that can be applied at the same time, and can they each have their...

    Read more.
  • replied to this:
    DistanceAlong Property from Bentley.CifNET.LinearGeometry in OpenRail model of equipment object using C#

    Hi,

    I would like to know if anyone here could help me how to get the value in Equipment and "Centerline Distance" from a Element placed through "Place Equipment" with a centerline as reference.

    I would like to get the value through...

    Read more.
  • 04g. Model Fluid / Gas Density in AutoPIPE
    Comments, Questions, and Answers: Item #1:

    How to model fluid / gas density in AutoPIPE?

    Answer:

    Using AutoPIPE V8i 09.06.xx.xx, a user can input the contents density value on the Pipe Properties dialog screen / Input grid:

    Note: As mentioned in AutoPIPE...

    Read more.