• replied to this:
    New Release - STAAD.Pro v2023 1

    A new version of STAAD.Pro 2023 has been published, 23.00.01.025. This is a minor release that has addressed two issues which have been discovered that cause the initial release to crash. These both relate to reporting. The first relates to use of the...

    Read more.
  • suggested an answer to this:
    Vertical Cross Bracing Failed.

    I got two filed column, then I added cross bracing there, coulmn found passed but the brcaing is not passes, not with big section. Please check the issue. you can change the type of bracing, please make the bracing pass. If we can omit the bracing and...

    Read more.
  • suggested an answer to this:
    Why my Purchased Staad Pro Shows in to Evaluation ?

  • replied to this:
    Required details of Extra usage of License

    Dear Team,

    We have 3 separate perpetual licenses for our engineers, they are using separately, Can your pls let us know which email ID is using in more than 1 device?

    Kindly provide details.  

    Contact details:

    Number - 8850541399 

    Email- Accounts@desteqengineers...

    Read more.
  • @Mention works inconsistently

    @Mention lets us mention another member of the community to provide a contextual reference to that member's bio and other information.

    Sometime in 2023 Be Communities changed the @Mention feature. It's supposed to be enhanced, but doesn't work....

    Read more.
  • replied to this:
    MSX [SOURCES] bug report

    Hi,

    The SETPOINT and CONCEN soureTypes are quite bugged in the latest version of WaterGEMS and CAD (10.04.00.108). 

    So far I had been able to function with workarounds to the bugs but now I've encountered a point I can't figure out a workaround for. I...

    Read more.
  • replied to this:
    Why manhole rim elevation assigned to pipe crown level?

    Manhole rim elevation ref assign to proposed ground elevation. Still when seen in profile view manhole is not seen correctly.Refer Image below:

  • suggested an answer to this:
    请帮我看一下图片中的问题怎么解决。

  • replied to this:
    Unable to assign longitudinal slope to on grade inlet in open road designer/sewergems

    Unable to assign longitudinal slope to on grade inlet in open road designer/sewergems

  • suggested an answer to this:
    Drift at Control Points

    For a current framing, I was able to get drift at control points per the original location of the column (0,0). Due to architectural changes , I had to shift the grids and the new location of the column is (-0.67, -0.75). When I check for the drift at...

    Read more.
  • suggested an answer to this:
    Punching check not found on slab

    I am getting an error for "Punching Check not found in slab".  I have deleted the circle after the column moved and added a new one centered on the new column location per past forums.  Are there other ways that this error can present itself?

  • suggested an answer to this:
    [Connection client] System error

    Unable to open MS2023 it freezes on startup screen and even if connection client is logged in doesn't help. At least v8i SS4 still opens.

    Health check:

    Starting Check...
    Checking Service
    Checking CONNECTION client...
    Checking Windows file permissions...

    Read more.
  • SELECTION OF FEW COMBINATION LOAD CASES FOR ANALYSIS IN STAAD PRO

    Hello i would like to know if this is possible,lets assume i have load combination created manually from load case 20 to load case 90,now on performing analysis i want to include only few combination maybe from load case 70 to 90 only how can i do this...

    Read more.
  • and 3 others earned the Ask A Question I achievement.
    Ask A Question I
  • Sample Model and Sketchup export issues

    Hi all, I just downloaded the trial version of Open Buildings Designer Connect Edition and have two questions/issues:

    1) I would like to know where I can get a sample model I can start playing with to familiarize myself with the program.

    2) Exporting...

    Read more.
  • replied to this:
    asked a question in ProStructures > ProSteel Forum:
    How do I make this graphic section appear?

    I am currently on AutoCAD 2011 and using ProStructures V8i SELECTSeries 3. However, the graphic indicated in red would not appear, is there a particular setting that is not enabled?

  • PW何如将一个文件在多个不同的文件内进行关联,达到修改其中一个,其他几个同步修改的目的?

    如主题

  • replied to this:
    【MS CE】升级OPM软件版本后msApp.CreateShapeElement1执行报错

    BIM.ShapeElement shapeEle1 = msApp.CreateShapeElement1(null, ref vectices1);

    升级OPM软件版本后,上述代码执行报错,升级后的版本如下

  • replied to this:
    【MSCE C#】winform窗口使用MS图标

    各位老师,请问在MSCE C#开发中,如何窗口使用MS/当前所选产品的(比如obd,ord)的图标呢。貌似C++开发中是可以自动带的

  • when i rotate geometry using a general rotate, i got the error report for deflection check.

    As per the subject.

    I generated a structure as below picture. 

    And i input the dj1,dj2 parameter for the deflection check as below.

    And i analyzed it and there was no error message.

    but i want to check lifting case, so i did rotating 15degree  geometry...

    Read more.