• Robert Hook
    Robert Hook edited this:
    Henrique Nacamae
    Henrique Nacamae in Civil Programming > Civil Programming - Wiki:
    OpenRoads Designer SDK - Developer Guide
    Contents

    Setting Up for Development (Related: Getting Started with ORD SDK Video)

    • Run the Developer Shell
    • Managed vs Unmanaged Projects

    Using the Example

    • Build a Single Example
    • Build All Examples
    • Running Custom Projects in OpenRoads Designer

    Overview...

    Read more.
    • over 3 years ago
    • More
    • Cancel
  • Ankit Kulkarni
    Ankit Kulkarni edited this:
    Yashodhan Joshi
    Yashodhan Joshi in OpenFlows | Water Infrastructure > OpenFlows | Water Infrastructure Wiki:
    How to use the Modified Hazen-Williams formula for analysis in WaterGEMS / WaterCAD / HAMMER?
    Product(s): WaterGEMS, WaterCAD Version(s): CONNECT Edition, V8i Area: Calculations
    Problem

    How to use the Modified Hazen-Williams formula for analysis in WaterGEMS / WaterCAD?

    Background

    In some parts of the world the Modified Hazen-Williams...

    Read more.
    • 5 minutes ago
    • More
    • Cancel
  • Joseph Lucas Magare
    Joseph Lucas Magare replied to this:
    Joseph Lucas Magare
    Joseph Lucas Magare asked a question in RAM | STAAD | ADINA > RAM | STAAD Forum:
    PLATE NEGATIVE MOMENT BEAM SLAB JOINT (SLAB MOMENT ) IN STAAD.PRO C.E

    Hello i would like to know why a joint of beam and slab does not show hogging moment instead sagging moment is occurring.

    Iam attaching my STAAD model

    C.STD

    Read more.
    • 1 hour ago
    • More
    • Cancel
    • View more replies
    • Joseph Lucas Magare Joseph Lucas Magare in reply to Modestas

      Ok thank you,i have more questions

      1.In this case my span of this slab will 7200mm by 6230mm instead of 3600 x 6230mm?

      2.From your experience,if i want to make judgement of using finite element or table coefficient,what is the ratio limit of stiffnes...

      Read more.
      • 6 minutes ago
      • More
      • Cancel
    • Joseph Lucas Magare Joseph Lucas Magare in reply to Modestas

      Ok thank you,i have more questions

      1.In this case my span of this slab will 7200mm by 6230mm instead of 3600 x 6230mm?

      2.From your experience,if i want to make judgement of using finite element or table coefficient,what is the ratio limit of stiffnes...

      Read more.
      • 6 minutes ago
      • More
      • Cancel
  • Matt Sparacino
    Matt Sparacino replied to this:
    Matt Sparacino
    Matt Sparacino asked a question in RAM | STAAD | ADINA > RAM | STAAD Forum:
    RAM Concept - Large moment at the edge of mat slab

    I am designing a mat slab foundation beneath a series of concrete shearwalls using ram concept. At the corner of the mat slab, an excessive amount of program reinforcement is being specified, and in looking at the section analysis, is due to a very large...

    Read more.
    • 2 days ago
    • More
    • Cancel
    • View more replies
    • Seth Guthrie Seth Guthrie

      Are you getting a reasonable soil stress plot and convergence? It looks like a flat slab (no steps) and you are plotting strip forces I think. What load combination?

      • 2 days ago
      • More
      • Cancel
    • Matt Sparacino Matt Sparacino in reply to Seth Guthrie

      Seth,

      I've attached the max soil pressure plot, it seems reasonable enough. This is indeed a flat slab and I am plotting the strength design layer on the section analysis, though the strip plot produces basically the same diagrams. While my plot from...

      Read more.
      • 45 minutes ago
      • More
      • Cancel
  • dkleinot
    dkleinot replied to this:
    dkleinot
    dkleinot asked a question in MicroStation > MicroStation Forum:
    [MS2023.00.01.44] Item Type "Is default value" not updating.

    In MS2023 a new option was added in the Item Types, "Is default value".  This allows the user to change the value of a Calculated Property.  This does not update as the element the Item Type is attached to moves.

    For example, If I add a property...

    Read more.
    • 18 days ago
    • More
    • Cancel
    • View more replies
    • Nilesh S Nilesh S in reply to dkleinot Verified Answer

      Hello, 

      The 'Is Default Value' was added to enable users to use get the calculated value for the first time. Once placed or during placement this field is editable and can be changed. The Item Type using the 'Is Default Value ' will not be calculated using...

      Read more.
      • 5 days ago
      • More
      • Cancel
    • dkleinot dkleinot in reply to Nilesh S

      Thanks you for the detailed response!  I will put in a Aha! for this to be changed.

      #4 isn't accurate tho.  If I set a Number or Integer type to Zero, it will revert to the calculated value.

      • 54 minutes ago
      • More
      • Cancel
  • Faseel Khan
    Faseel Khan suggested an answer to this:
    vincent leong seng
    vincent leong seng asked a question in GeoStudio | PLAXIS > GeoStudio | PLAXIS Forum:
    HOW TO MODEL SOFT SOIL CREEP MODEL IN PLAXIS LE?

    HOW TO MODEL SOFT SOIL CREEP MODEL IN PLAXIS LE?

    • 3 days ago
    • More
    • Cancel
    • View more replies
    • vincent leong seng vincent leong seng in reply to Faseel Khan

      Analysis about settlement characteristic of road embanment over soft soil ... in my analysis i need added PVD to speed up consolidation . so how to add the PVD in my analysis?

      • 23 hours ago
      • More
      • Cancel
    • Faseel Khan Faseel Khan in reply to vincent leong seng Suggested Answer

      PLAXIS LE does not have a dedicated drain boundary condition. You could try the Review Boundary, which is similar to a drain or a seepage face, otherwise only the standard constant Excess PWP, Head, or Pressure Head boundary conditions are implemented.
      The only...

      Read more.
      • 54 minutes ago
      • More
      • Cancel
  • Robert Hook
    Robert Hook replied to this:
    Hippocritical
    Hippocritical asked a question in MicroStation Programming > MicroStation Programming Forum:
    how to get a list of all layers // how to select all contents of that layer

    Hi,

    Version : Microstation CONNECT Edition Update 11 - Version 10.11.00.36

    We are currently working on the conversion from dgn to DXF but it fails since the models are ginormous.
    To circumvent that we came to the idea that we could split the files into...

    Read more.
    • 6 days ago
    • More
    • Cancel
    • View more replies
    • Leonard Jones Leonard Jones in reply to Paul Mitache

      Yes, syntax is correct. Check wiki 101 ways to set your active level

      Make sure if the Level exists.

      If you have Space or Special characters, then wrap with quotes e.g. LV="My Level"

      Read more.
      • 1 day ago
      • More
      • Cancel
    • Robert Hook Robert Hook in reply to Paul Mitache

      Hi Paul Mitache ,

      Can you confirm you created a Level Name called "Empty" and the code snippet is not working?

      Leonard Jones said:
      Create an Empty level

      And possibly show your code that calls:

      Sub TurnOnLvl(lvlName As String)

      HTH,
      Bob

      Read more.
      • 55 minutes ago
      • More
      • Cancel
  • Robert Pierce
    Robert Pierce and 7 others earned the Ask A Question I achievement.
    Ask A Question I
    • 12 hours ago
    • More
    • Cancel
  • Bentley Do Not Change Systems Do Not Change
    Bentley Do Not Change Systems Do Not Change asked a question in Bentley 中国优先社区 > ◆ 二次开发(MicroStation编程, ProjectWise编程等):
    [MS C++]python

    你好,我想请问一下,bmake编译过程中,如何加入python解释器。

    原因呢,是我想使用c++调用python脚本。

    目前我解决了文件依赖问题,比如在bmake文件中加入以下命令。

    LINKER_LIBRARIES = $(mdlLibs)bentley.lib \
    	           $(mdlLibs)mdlbltin.lib \
            	   $(mdlLibs)BentleyGeom.lib \
                       $(mdlLibs)DgnPlatform...

    Read more.
    • 1 hour ago
    • More
    • Cancel
  • Faseel Khan
    Faseel Khan suggested an answer to this:
    xin Fang
    xin Fang asked a question in GeoStudio | PLAXIS > GeoStudio | PLAXIS Forum:
    Mstage and Surface load

    Hi Plaxis Forum

    I have a model of a shield tunnel in plaxis3d. The model is run to an Mstage=0,8 for the excavation of the tunnel (Phase 1); in the following phase, a concrete lining is activated and the model run to Mstage=1 (Phase 2).

    My question is...

    Read more.
    • 3 days ago
    • More
    • Cancel
    • View more replies
    • xin Fang xin Fang in reply to Faseel Khan

      Thank you for your reply, does that mean that no matter whether I manually set ΣMstage or not ,at every phase, the weight of the structure, the weight of the soil and any load we put on the structure will gradually increase from 0 until the overall...

      Read more.
      • 2 days ago
      • More
      • Cancel
    • Faseel Khan Faseel Khan in reply to xin Fang Suggested Answer

      Yes whenever an unbalance is created it will be solved gradually linearly in time. For example, increasing a load and deactivating soil elements will create an unbalance in a phase. Then the total unbalance of those two changes is determined, and Sum Mstage...

      Read more.
      • 1 hour ago
      • More
      • Cancel
  • Patrick Hsu
    Patrick Hsu replied to this:
    Patrick Hsu
    Patrick Hsu asked a question in ProjectWise > ProjectWise Design Integration Forum:
    What's the correct syntax to SQL select documents that are created today?

    see my reply

    • 1 hour ago
    • More
    • Cancel
    • Patrick Hsu Patrick Hsu

      please see error message screenshot below 

      • 1 hour ago
      • More
      • Cancel
  • Chetan Gorde
    Chetan Gorde asked a question in OpenFlows | Water Infrastructure > OpenFlows | Water Infrastructure Forum:
    Multiple selection set creation at the time importing from GIS based on Zones.

    I have to create multiple selection set after importing from GIS shape file in watergems model builder. So it is very time taking process for creating selection sets of no of zones are in more than 100.

    • 1 hour ago
    • More
    • Cancel
  • Satish Saptasagar
    Satish Saptasagar edited this:
    Satish Saptasagar
    Satish Saptasagar in OpenUtilities > OpenUtilities Wiki:
    Error message when Installing Promis.e CONNECT related to Microsoft Access or Microsoft Office 365
      Product(s): Promis.e CONNECT Edition   Version(s):  10.13.XX.XX through    Environment:  NA   Area:  Installation_Configuration    Subarea:  Installation Error

    Background:

    Historically Access Database Engines (ADE) have been used OUS & Promis...

    Read more.
    • 1 hour ago
    • More
    • Cancel
  • Abhay Gore
    Abhay Gore suggested an answer to this:
    Austin White
    Austin White asked a question in OpenRoads | OpenSite > OpenRoads | OpenSite Forum:
    Sort Groups & Aggregates in Report

    I'm trying to create a report that uses Groups and Aggregates. There are 2 properties grouped together, one is a Repair Type, and the other is an Item that is associated with the Repair Type. The Aggregate is the sum of the quantity of the item. The report...

    Read more.
    • 16 days ago
    • More
    • Cancel
    • View more replies
    • Austin White Austin White in reply to Mark Winegar

      I'm actually using OpenRoads Designer version 10.10

      • 6 days ago
      • More
      • Cancel
    • Abhay Gore Abhay Gore Suggested Answer

      Hi Austin,

      Thanks for sharing dataset.
      I have reported a bug for this issue.

      Thanks,
      Abhay

      • 2 hours ago
      • More
      • Cancel
  • f.mandoki
    f.mandoki replied to this:
    Duncan Gammie
    Duncan Gammie asked a question in MicroStation > MicroStation Forum:
    Parametric cell speed

    The time taken to load and change parametric cells is ridiculously slow. Is anyone aware of any tricks to speed this up? 

    • 1 month ago
    • More
    • Cancel
    • View more replies
    • Duncan Gammie Duncan Gammie in reply to Melissa Hook

      I do, but I turn them off to test and doesn't make any appreciable difference. 
      Also a bit of a cop out from Bentley to say close this/close that, or have you reset prefs. Just make the dialogs work without lag. 

      • 2 hours ago
      • More
      • Cancel
    • f.mandoki f.mandoki in reply to Duncan Gammie

      Well, it definitely makes a difference if you have the properties window open when selecting a few hundred elements to e.g. move them. I don't know if that has any effect in your case, though.

      • 2 hours ago
      • More
      • Cancel
  • Firdevs Kayadan
    Firdevs Kayadan asked a question in Licensing, Cloud and Web Services > Licensing, Cloud and Web Services Forum:
    gINT HoleBASESI and Openground

    I have data in GPJ format, and in HoleBASE, there is a 'gINT' option. However, I am unable to utilize the 'add' button. How can I convert the gINT file into HoleBASE?

    • 2 hours ago
    • More
    • Cancel
  • Jutta Eisenhauer
    Jutta Eisenhauer replied to this:
    Wolfgang Ziwitza
    Wolfgang Ziwitza asked a question in MicroStation > MicroStation Forum (Deutsch):
    Term License for MicroStation

    Hallo zusammen,

    ich habe heute folgende Email von Bentley erhalten:

    Bentley - Benachrichtigung über befristete Lizenzen (MicroStation)

    Benutzer (Benutzername) bei (Firmenname), hat am 1000.11.6 2023:7:40 eine befristete Lizenz für MicroStation ...

    Read more.
    • 5 hours ago
    • More
    • Cancel
    • View more replies
    • A_F A_F in reply to Wolfgang Ziwitza Suggested Answer
      Die Anfrage wurde bei uns eingeloggt und an unsere Lizenzabteilung weitergeleitet: CS0111201
      VG, Andrea
      • 3 hours ago
      • More
      • Cancel
    • Jutta Eisenhauer Jutta Eisenhauer

      Hallo Herr Ziwitza,

      die Bearbeitung Ihrer Anfrage wurde von mir übernommen.
      Ich untersuche Ihren Fall und melde mich schnellstmöglich zurück. 

      Mit besten Grüßen
      Jutta Kremer

      Read more.
      • 3 hours ago
      • More
      • Cancel
  • Jingyuan Lv
    Jingyuan Lv suggested an answer to this:
    小雄 曾
    小雄 曾 asked a question in Bentley 中国优先社区 > ◆ 道路与场地设计(OpenRoads for China, OpenRoads, PowerCivil等):
    土木单元放置

    您好,我在放置土木单元时不知道为何路面和人人行道会不在同一标高上,如下图所示: ,支路纵断面模型如下所示: 路面模板边线

    • 3 days ago
    • More
    • Cancel
    • View more replies
    • 小雄 曾 小雄 曾 in reply to Jingyuan Lv

      已发您邮箱

      • 3 hours ago
      • More
      • Cancel
    • Jingyuan Lv Jingyuan Lv in reply to 小雄 曾 Suggested Answer

      您好,已经检查了您的视频。发现您没有给我提供另外两个参考文件。所以暂时没法复现您的问题。

      初步怀疑下图所示路线高程的问题。

      • 2 hours ago
      • More
      • Cancel
  • baocheng 苑
    baocheng 苑 asked a question in Bentley 中国优先社区 > ◆ 道路与场地设计(OpenRoads for China, OpenRoads, PowerCivil等):
    open tunnel放置锚杆的问题

    您好,模型里我已经放置了一排锚杆,我还想沿着隧道的外轮廓再放置锚杆,并且设置他的角度,请问可以实现吗?

    • 3 hours ago
    • More
    • Cancel
  • Steffen Knoll
    Steffen Knoll in ProStructures > ProStructures Wiki (Deutsch):
    Zentrale für Benutzerteile im Workset integrieren
      Produkt(e): ProSteel 3D Professional           Version(en): CONNECT Edition   Umgebung: Windows   Produktbereich: Allgemein Problem

    Wie kann man die Zentrale für Benutzerteile im Workset integrieren?

    Problemlösung

    Am besten den Ordner...

    Read more.
    • 3 hours ago
    • More
    • Cancel