• Agapito Associates
    Agapito Associates asked a question in OpenGround | gINT | Keynetix > gINT Forum:
    Text vs Depth Formatting Questions

    1) How do I add/format proper callouts to my text expression in my strata description? (Image 1.1, 2.1)

    Image 1.1 (Desired Output)

    2) Why is my strata description repeating at the top of each page? Also, why am I receiving text for areas where there is...

    Read more.
    • 1 hour ago
    • More
    • Cancel
  • Chris Carter
    Chris Carter edited this:
    Jeremy Hoesly
    Jeremy Hoesly in Licensing, Cloud and Web Services > Licensing, Cloud and Web Services Wiki:
    Page Expired error when signing into ProjectWise Analytical Data Upload Service
      Applies To    Product(s): ProjectWise Analytical Data Upload Service   Version(s): 01.00.02.250   Environment:  All   Area:  IMS Error

    A user encounters the following error when attempting to sign into IMS from within ProjectWise Analytical...

    Read more.
    • 1 hour ago
    • More
    • Cancel
  • Luca Santos Billis
    Luca Santos Billis edited this:
    Luca Santos Billis
    Luca Santos Billis in OpenFlows | Water Infrastructure > OpenFlows | Water Infrastructure Wiki (Português):
    Notificação do usuário: "Pump cannot deliver flow or head"
    Aplica-se a Produto(s): WaterGEMS, WaterCAD, HAMMER, SewerCAD, SewerGEMS, CivilStorm Versão(ões): CONNECT Edition, V8i Área: Cálculos Autor Original: Terry Foster, Grupo de Suporte Técnico da Bentley ... Read more.
    • 14 days ago
    • More
    • Cancel
  • chao jin
    chao jin and 11 others earned the Ask A Question I achievement.
    Ask A Question I
    • 15 hours ago
    • More
    • Cancel
  • Stephen Romero
    Stephen Romero asked a question in OpenRoads | OpenSite > OpenRoads | OpenSite Forum:
    Suda- Profiles and Alignments

    Hello,

    I have a question that Im not sure has been answered on here, but basically I am trying to generate profiles for storm sewers that generate in reference to an existing alignment. As it stands right now, when I generate a profile for a storm sewer...

    Read more.
    • 2 hours ago
    • More
    • Cancel
  • Vivien Lee
    Vivien Lee asked a question in ProjectWise Programming > ProjectWise Programming Forum:
    How can I use object GUID, Project ID and Document ID in search?

    One of the column in the viewer of our data source is Object GUID. Is there a way I can search a specific document using only this detail? 

    Also, some of the error message in PDF rendition shows a user doesn't have access to specific Project ID and Document...

    Read more.
    • 2 hours ago
    • More
    • Cancel
  • Manuel Robles
    Manuel Robles replied to this:
    Manuel Robles
    Manuel Robles asked a question in RAM | STAAD | ADINA > RAM | STAAD Forum:
    AREAS DE CARGA RAM ELEMENTS

    How can a load area distribute loads on a vertical plate that represents a shear wall, just as a slab does?

    Thanks a lot

    • 6 days ago
    • More
    • Cancel
    • View more replies
    • Seth Guthrie Seth Guthrie Verified Answer

      Walls (Shells) do not work with area loads. Your best bet will be to add a beam along the top of the wall. The load can then be applied to the beam which in turn will transfer load to the wall at the nodes of the mesh. As long as the beam is not overly...

      Read more.
      • 2 hours ago
      • More
      • Cancel
    • Manuel Robles Manuel Robles in reply to Seth Guthrie

      Okay. Thank you so much. It would be helpful to improve that detail, and also add slab over springs.

      • 2 hours ago
      • More
      • Cancel
  • Andrew Golden
    Andrew Golden asked a question in OpenRoads | OpenSite > OpenRoads | OpenSite Forum:
    Rotating Plan Production Sheet

    I am looking to rotate a plan production sheet 180 degrees. Is there a good way to go about doing this? 

    • 2 hours ago
    • More
    • Cancel
    • MaryB MaryB

      Rotate the view? the sheet? the plan attachment?

      • 27 minutes ago
      • More
      • Cancel
  • 王帅 王
    王帅 王 replied to this:
    王帅 王
    王帅 王 asked a question in Bentley 中国优先社区 > ◆ 设计平台软件(MicroStation,PowerDraft, Navigator, i-model等):
    microstation 闪退问题

    软件打开正常,选择文件后就闪退 6378.exception.log

    • 2 hours ago
    • More
    • Cancel
    • 王帅 王 王帅 王

      CE版本,UPDATE17,重装过很多次都不行

      • 2 hours ago
      • More
      • Cancel
  • Sylvia H.
    Sylvia H. edited this:
    Jennifer Gebhard
    Jennifer Gebhard in Bentley Support > Bentley Support Wiki:
    Bentley Portal Update - Important Change for Bentley’s Help Desk and new URL as of May 2023

    With the launch of the new Bentley Support Portal in ServiceNow (SN), users can quickly access our Bentley Communities forums and knowledge articles to quickly and efficiently self-serve and troubleshoot software and other service issues as they arise...

    Read more.
    • over 1 year ago
    • More
    • Cancel
  • Carlos Perez
    Carlos Perez replied to this:
    Austin Kirsch
    Austin Kirsch asked a question in RAM | STAAD | ADINA > RAM | STAAD Forum:
    RAM Elements 2023 Update - Shell Stiffness and Flexible Diaphragms

    With the latest RAM Elements update, it is possible to independently define bending and membrane releases and stiffness modifiers. I played with this new feature a bit today to mimic flexible diaphragm behavior, but couldn't seem to figure out a sweet...

    Read more.
    • 27 days ago
    • More
    • Cancel
    • View more replies
    • Austin Kirsch Austin Kirsch in reply to Carlos Perez

      Thanks for the reply. I think I just got excited a bit too soon after seeing this update. Based on your reply and myself having more time to investigate, this update doesn't really do anything to further RAM Element's ability to model diaphragm flexibility...

      Read more.
      • 24 days ago
      • More
      • Cancel
    • Carlos Perez Carlos Perez in reply to Austin Kirsch

      There is still some work to do but this is a first step in that direction. You can try for example to use a very low in plane factors and check how loads are distributed like in the simple example below. Setting these low values for the in plane DOFs...

      Read more.
      • 2 hours ago
      • More
      • Cancel
  • Ricardo Alarcon
    Ricardo Alarcon suggested an answer to this:
    Quraish Shamim
    Quraish Shamim asked a question in MAXSURF | MOSES | SACS | OpenWindPower > MAXSURF | MOSES | SACS | OpenWindPower Forum:
    Warning during Spectral Fatigue Post Processing

    Hi all, I have these warning messages after performing the Spectral Fatigue Post Processing. I don't really understand why these warnings occur. Can anyone provide any advice on how to solve these warnings? Thanks

    Note, I am using SACS version ...

    Read more.
    • 14 hours ago
    • More
    • Cancel
    • Ricardo Alarcon Ricardo Alarcon Suggested Answer

      The first warning make reference to the title in your analysis, Please check the size of this, could be too large

      For the second, this makes reference that the SCF calculated for the connection 1687 which exceeds of 100, you can calculate these values...

      Read more.
      • 3 hours ago
      • More
      • Cancel
  • Jesse Dringoli
    Jesse Dringoli suggested an answer to this:
    Luis Bergonzini
    Luis Bergonzini asked a question in OpenFlows | Water Infrastructure > OpenFlows | Water Infrastructure Forum:
    How to convert a file from the latest version of SewerGEMS to an older version?

    Hello everybody.

    To solve another problem, I used the latest version of SewerGEMS software to work on my project, as I intended to do 2D simulations. However, as it is a feature that is not available for summer students (unfortunately), it ended up...

    Read more.
    • 1 day ago
    • More
    • Cancel
    • View more replies
    • Luis Bergonzini Luis Bergonzini in reply to Ankit Kulkarni

      Hello Ankit.

      I exported in SWMM but some elements changed their typologies. My catch basins became manholes, as did the sections of the macrodrainage channel. Furthermore, the canals became conduits. I would like to return to their old typology. Is there...

      Read more.
      • 5 hours ago
      • More
      • Cancel
    • Jesse Dringoli Jesse Dringoli in reply to Luis Bergonzini Suggested Answer

      Luis, there is no catchbasin element in the SWMM file format (not until the 5.2 format that we will support later) which is why the catchbasins are exported as Junction nodes in the SWMM INP file.

      Similarly there is no channel element in SWMM so they...

      Read more.
      • 3 hours ago
      • More
      • Cancel
  • Nicolas Barbero
    Nicolas Barbero and David S earned the Let me Help You achievement.
    Let me Help You
    • 9 hours ago
    • More
    • Cancel
  • David S
    David S suggested an answer to this:
    David S
    David S asked a question in OpenRoads | OpenSite > OpenRoads | OpenSite Forum:
    Most efficient way to update the Font Name in our office standards?

    We use several standards that currently have the LEROY font for all text nodes.  What is the most efficient way to convert all text nodes to Engineering Regular? 

    My current process is to use Select By Attributes to select all Text and Text Node elements...

    Read more.
    • 1 day ago
    • More
    • Cancel
    • View more replies
    • MaryB MaryB Verified Answer

      Do you use text styles in DGNLIB files? Is this change only for these drawings, or is it going to be a universal update?

      Even without changing the text style, you can change the font on all of the text in a drawing with one tool. If you select all the...

      Read more.
      • 19 hours ago
      • More
      • Cancel
    • David S David S Verified Answer

      Thanks, MaryB - this worked great!

      As stated by Mary, here are the steps: 

      In the Drawing workflow: 
      1.  Home tab > Primary group > Select By Attributes tool .   Under "Types", select Cell (if any cells contain text), Text, and Text Node.  Execute...

      Read more.
      • 3 hours ago
      • More
      • Cancel
  • Jesse Dringoli
    Jesse Dringoli edited this:
    Larry Abla
    Larry Abla in OpenFlows | Water Infrastructure > OpenFlows | Water Infrastructure Wiki:
    What are the limitations of importing/exporting SWMM5 files?
    Product(s): CivilStorm, SewerGEMS Version(s): 08.11.XX.XX and higher Area:  Layout and Data Input

    Introduction

    This article explains the limitations you need to be aware of when importing or exporting EPA SWMM5 INP format.

    In general, you can...

    Read more.
    • 7 months ago
    • More
    • Cancel
  • Stefanos Papavasileiou
    Stefanos Papavasileiou edited this:
    Stefanos Papavasileiou
    Stefanos Papavasileiou in GeoStudio | PLAXIS > GeoStudio | PLAXIS Wiki:
    Dynamic point loads in axisymmetric 2D models do not consider the radius
    Application PLAXIS 2D Issue status  Solved First Affected Version PLAXIS 2D Anniversary Edition Found in Version PLAXIS 2D Anniversary Edition
    PLAXIS 2D 2015-2019
    PLAXIS CONNECT Edition V20-V22
    PLAXIS 2023.1 Fixed and Released in Version PLAXIS...
    Read more.
    • 6 months ago
    • More
    • Cancel
  • Giselle Notte
    Giselle Notte edited this:
    Joseph Marin
    Joseph Marin in Asset Reliability | AssetWise APM > Asset Reliability | AssetWise APM Wiki:
    DCOM hardening caused ODC DA connections to break
      Product(s): APM Implementation and Performance Management   Version(s): 7   Environment: N/A   Area: N/A   Subarea: N/A Problem Description

    An APM user had reported that the ODC DA service has stopped returning data. They were migrating...

    Read more.
    • 10 months ago
    • More
    • Cancel
  • Giselle Notte
    Giselle Notte edited this:
    Joseph Marin
    Joseph Marin in Asset Reliability | AssetWise APM > Asset Reliability | AssetWise APM Wiki:
    ODC Indicator reading failing to poll from ODC Database when running historical entries
      Product(s): APM Implementation and Performance Management   Version(s): 7.10   Environment: N\A   Area: N/A   Subarea: N\A

    Problem

    When trying to use the Online Data Collection functionality pointing to an ODC Database Datasource, the...

    Read more.
    • 3 hours ago
    • More
    • Cancel
  • Giselle Notte
    Giselle Notte edited this:
    Giselle Notte
    Giselle Notte in Asset Reliability | AssetWise APM > Asset Reliability | AssetWise APM Wiki:
    ODC Agent not reporting readings in QA environment after DB refresh from Production
      Product(s): APM Implementation and Performance Management   Version(s): All versions   Environment: N\A   Area: N/A   Subarea: N\A

    Problem

    On Prem ODC Agent no longer working in QA after refresh from Production Database.  We haven't seen...

    Read more.
    • 3 hours ago
    • More
    • Cancel