• danny-cooley
    danny-cooley replied to this:
    danny-cooley
    danny-cooley asked a question in OpenBuildings | AECOsim | Speedikon > OpenBuildings | AECOsim | Speedikon | Forum:
    Foundations- - Spread footing, strip footing ....

    Hello all

    OBD Update 10

    Am testing out the Structural tools.

    There does not seem to be a tool for 'Foundations: Spread Footing ..... or Strip Footing

    In the Catalogue there are 'Foundation | Mat Foundation, Foundation | Spread Footing and Foundation...

    Read more.
    • 1 month ago
    • More
    • Cancel
    • View more replies
    • Johan De Cock Johan De Cock Suggested Answer

      Hello Danny,

      currently OBD is missing the propert tools for actual Foundation modelling. There are some workarounds as explained in these videos:

      https://www.youtube.com/watch?v=t88ZA85K3q8&t=202s 

      https://www.youtube.com/watch?v=gw8YNRfQd2g&t=197...

      Read more.
      • 29 days ago
      • More
      • Cancel
    • danny-cooley danny-cooley in reply to Johan De Cock

      Hello

      yes, have added my vote.

      Must say, am also getting serious problems with Level Display Dialog not working with elements I have created. Frequently, when I try to turn OFF those Levels (S-Fdns or something like that), by clicking on the Level Name...

      Read more.
      • 44 minutes ago
      • More
      • Cancel
  • Mike Dattilio
    Mike Dattilio edited this:
    Mike Dattilio
    Mike Dattilio in AutoPIPE > AutoPIPE Wiki:
    02. Featured and Bugs Logged for AutoPIPE
    Problem: What enhancement / defects request have already been logged for AutoPIPE?

    Note:

    If an feature or bug has not been added to the program,

    • For features, use instructions here to log a new IDEA. The more votes logged per an IDEA, the quicker the CAE...
    Read more.
    • 44 minutes ago
    • More
    • Cancel
  • danny-cooley
    danny-cooley replied to this:
    danny-cooley
    danny-cooley asked a question in OpenBuildings | AECOsim | Speedikon > OpenBuildings | AECOsim | Speedikon | Forum:
    Named Groups Dialog Box not appearing

    Hello

    From the Help Documentation

    'To Create a Named Group from the Named Groups Dialog

    1. Use the Element Selection tool to select the element(s) to be included in the named group.
    2. Select Drawing > Home > Groups dialog launcher.

      The Named Groups dialog...

    Read more.
    • 17 days ago
    • More
    • Cancel
    • View more replies
    • Thomas Voghera Thomas Voghera in reply to Thomas Voghera

      SHIFT-right click > pointer menu >Quickset save >1-0

      • 17 days ago
      • More
      • Cancel
    • danny-cooley danny-cooley in reply to Thomas Voghera

      OK, I see, ...... I seem to recall it working differently some years ago. I must admit I jumped ahead an didn't read the instructions properly.

      I would like to add though ...... It now seems that when you go to create a 'Graphic Group', then the default...

      Read more.
      • 50 minutes ago
      • More
      • Cancel
  • Hazim Al
    Hazim Al asked a question in RAM | STAAD | ADINA > RAM | STAAD Forum:
    RAM Element/ beam Module/ Tributary width/ wall footings

    I suggest to add a tributary width(ft) to the beam module, it will be just easy to enter loads in (psf).

    Any updates on addling wall footings to RAM Elements MODULES?

    • 51 minutes ago
    • More
    • Cancel
  • Mike Dattilio
    Mike Dattilio edited this:
    Mike Dattilio
    Mike Dattilio in AutoPIPE > AutoPIPE Wiki:
    03. How to update AutoPIPE with a new piping code or a new Code Compliance Calculation? or Can I use a different edition of the same code and get the same results until the new Piping code has been added to AutoPIPE?
    Applies To Product(s): AutoPIPE, Version(s): ALL Area: Piping Codes Original Author: Bentley Technical Support Group Problem:

    How to update AutoPIPE with a new piping code or a new Code Compliance Calculations? 

    Can I use...

    Read more.
    • 52 minutes ago
    • More
    • Cancel
  • Mostafa Abd Elmoaty
    Mostafa Abd Elmoaty replied to this:
    Mostafa Abd Elmoaty
    Mostafa Abd Elmoaty asked a question in OpenFlows | Water Infrastructure > OpenFlows | Water Infrastructure Forum:
    A problem during modeling surge valve at HAMMER software

    I have a transient model of pump failure, and I put a surge valve as a protective device. According to the following image and from the black line did not get back to the initial state of the system like it is failed.

    The hammer file is also attached.

    ... Read more.
    • 7 days ago
    • More
    • Cancel
    • View more replies
    • Jesse Dringoli Jesse Dringoli in reply to Mostafa Abd Elmoaty

      Most likely a check valve is closing in that case, preventing reverse flow (and the resulting downward sloping hydraulic grade from the headloss from that flow). Are you using a check valve at your pump station?

      • 1 day ago
      • More
      • Cancel
    • Mostafa Abd Elmoaty Mostafa Abd Elmoaty in reply to Jesse Dringoli

      I used the check valve at the transient operational settings of the pump.

      • 53 minutes ago
      • More
      • Cancel
  • Hazim Al
    Hazim Al replied to this:
    Hazim Al
    Hazim Al asked a question in RAM | STAAD | ADINA > RAM | STAAD Forum:
    Pre qualified moment frame in RAM connection

    I need to specify and design WUF-W Moment Connection in RAM Connection, is it available? 

    Also I don't see the shear angle in RBS in smart connection.

    • 8 days ago
    • More
    • Cancel
    • View more replies
    • Seth Guthrie Seth Guthrie Suggested Answer

      No, we don't specifically have the WUF-W types. Direct Welded joints, flange plates, & moment end plates only. The RBS details impact these moment connections but don't matter for a separate shear connection. 

      • 7 days ago
      • More
      • Cancel
    • Hazim Al Hazim Al in reply to Seth Guthrie

      Seth, thanks..

      What do you suggest for shear design inside the moment connection module (RBS)? shall I design the moment connection separately for shear and then add the moment connection.

      • 53 minutes ago
      • More
      • Cancel
  • 龙🐉
    龙🐉 replied to this:
    龙🐉
    龙🐉 asked a question in Bentley 中国优先社区 > ◆ CNCCBIM 系列产品:
    将三维约束好的参数化模型定义为单元后三维约束条件消失了

             

    • 6 days ago
    • More
    • Cancel
    • View more replies
    • Jing.Bai Jing.Bai in reply to 龙🐉 Verified Answer

       我这里下载了上面我上传的 5700.参数化.cel 文件,然后将其中的参数化单元放置到了一个新的DGN中,顿长和桩长好像都可以改变,录了个视频如下,是否操作和你那里有不一样的地方?

      Play this video

      Read more.
      • 2 days ago
      • More
      • Cancel
    • 龙🐉 龙🐉 in reply to Jing.Bai

      好的

      • 55 minutes ago
      • More
      • Cancel
  • Rosie Perez
    Rosie Perez and 9 others earned the Ask A Question I achievement.
    Ask A Question I
    • 5 hours ago
    • More
    • Cancel
  • Samet Karatas
    Samet Karatas asked a question in LARS | LEAP | OpenBridge | OpenTunnel | RM > LARS | LEAP | OpenBridge | OpenTunnel | RM Forum:
    I am designing a footing cap for drilled shaft using STM model as per AASHTO but getting error message for Tension ties in Z direction. it doesn't help if i provide hook or exra reinforcement.

    I am designing a footing cap for drilled shaft using STM model as per AASHTO but getting error message for Tension ties in Z direction.  it doesn't help if i provide hook or exra reinforcement. Could you please advise

    Thanks

    • 1 hour ago
    • More
    • Cancel
  • danny-cooley
    danny-cooley replied to this:
    danny-cooley
    danny-cooley asked a question in OpenBuildings | AECOsim | Speedikon > OpenBuildings | AECOsim | Speedikon | Forum:
    Update 10 - Quicksets seem to no longer be available

    Hello

    Update 10

    Just tried this ...

    'To Create a Quickset from the View Control Pop-up Menu

    1. Use the Element Selection tool to select the elements to be included.
    2. With the pointer in the view, press <Shift-Reset> to open the view control pop-up...
    Read more.
    • 17 days ago
    • More
    • Cancel
    • View more replies
    • Thomas Voghera Thomas Voghera in reply to Alifur Mandal

      Wouldn't it be better to ad the tool to the dialog?

      • 16 days ago
      • More
      • Cancel
    • danny-cooley danny-cooley in reply to Thomas Voghera

      Hello there

      Yes, certainly. If it exists, why isn't there an icon for it.

      Realistically, most people do not use 3-key shortcuts. Plus, they are not going to go through the Help Manual in great detail (especially looking for something that they don...

      Read more.
      • 1 hour ago
      • More
      • Cancel
  • Seth Guthrie
    Seth Guthrie suggested an answer to this:
    Sebina Kalawadwala
    Sebina Kalawadwala asked a question in RAM | STAAD | ADINA > RAM | STAAD Forum:
    Punching Shear Check - reduction in punch perimeter due to openings

    Hello,

    I am trying to perform some punching shear checks using RAM Concept, however, I am noticing that the program does not reduce the punch perimeter when there is an opening <10h away from column CL. According to ACI 318-14 Section 22.6.4.3, there...

    Read more.
    • 3 hours ago
    • More
    • Cancel
    • View more replies
    • Sebina Kalawadwala Sebina Kalawadwala in reply to Seth Guthrie

      Seth,

      That seems to have worked, thank you for your help!

      Another question I had was with regards to punching shear at the beams- there's not much clarity on how RAM does it in the documentation, can you point me to any other resources?

      • 1 hour ago
      • More
      • Cancel
    • Seth Guthrie Seth Guthrie in reply to Sebina Kalawadwala Suggested Answer

      Our wiki on punching shear mentions beams: communities.bentley.com/.../ram-concept-punching-shear-checks-faq

      • 1 hour ago
      • More
      • Cancel
  • danny-cooley
    danny-cooley replied to this:
    danny-cooley
    danny-cooley asked a question in OpenBuildings | AECOsim | Speedikon > OpenBuildings | AECOsim | Speedikon | Forum:
    Add Flange - Doesn't seem to work with Update 10

    hello

    OBD Update 10

    Am running through some of the online training (pretty good overall) ...

    Am now on 

    Bentley OpenBuildings Designer CONNECT Edition User Accreditation Learning Path

    View Learning Path (bentley.com)

    Chapter 7: Advanced Modeling - The...

    Read more.
    • 22 days ago
    • More
    • Cancel
    • View more replies
    • Steve Cocchi Steve Cocchi in reply to danny-cooley

      Hi Danny,

      I would suggest creating a support case so the team can investigate why end plates don't support flanges, and whether generic plates should automatically cut back the column. 

      In the interim, you can either modify the length of the column...

      Read more.
      • 14 days ago
      • More
      • Cancel
    • danny-cooley danny-cooley in reply to Steve Cocchi

      Hello

      I might (eventually) get around to submitting a ticket ..... in the meantime, I will just have to use the generic plate tool, and remember to shorten the related column as needed.

      Bit aggrieved though that I followed the instructions in the training...

      Read more.
      • 1 hour ago
      • More
      • Cancel
  • danny-cooley
    danny-cooley asked a question in OpenBuildings | AECOsim | Speedikon > OpenBuildings | AECOsim | Speedikon | Forum:
    Windows are not showing as transparent

    OBD Update 10

    I've been trying out some windows.

    For some reason, some of them appear transparent, but others do now.

    I've tried changing the glass type (many times) in the property panel. Including to a glass type that does show up transparent in...

    Read more.
    • 1 hour ago
    • More
    • Cancel
  • Seth Guthrie
    Seth Guthrie replied to this:
    Hazim Al
    Hazim Al asked a question in RAM | STAAD | ADINA > RAM | STAAD Forum:
    RAM Element/Wood Design Ci design factor

    Any ideas; how can add Ci to the design of wood members?

    Thanks 

    Hazim 

    • over 1 year ago
    • More
    • Cancel
    • View more replies
    • Hazim Al Hazim Al in reply to Seth Guthrie

      Hello,

      Any update if this is now in updated RAM elements VIRSION?

      • 1 hour ago
      • More
      • Cancel
    • Seth Guthrie Seth Guthrie in reply to Hazim Al

      No, that issue is still open.

      • 1 hour ago
      • More
      • Cancel
  • Dakota Dreyer
    Dakota Dreyer asked a question in Licensing, Cloud and Web Services > Licensing, Cloud and Web Services Forum:
    License Issue

    My company has assigned me a license, but Connection Client still shows that I am under a seven-day trial.  Any suggestions to remove the trial notifications?

    • 2 hours ago
    • More
    • Cancel
  • omar qassem
    omar qassem replied to this:
    omar qassem
    omar qassem asked a question in About Bentley Communities > Communities Feedback Forum:
    <h1>Ahmed</h1>

    <h1>Ahmed</h1>

    • 3 hours ago
    • More
    • Cancel
    • View more replies
    • omar qassem omar qassem

      <img src=x >

      • 3 hours ago
      • More
      • Cancel
    • omar qassem omar qassem

      Read more.
      • 3 hours ago
      • More
      • Cancel
  • Nayeem Ahmed
    Nayeem Ahmed asked a question in MicroStation Programming > MicroStation Programming Forum:
    VBA script to detach display off borders from MicroStation connect edition ?

    VBA script to detach display off borders from MicroStation connect edition ?

    • 3 hours ago
    • More
    • Cancel
  • Klaudia Piekielniak
    Klaudia Piekielniak edited this:
    Klaudia Piekielniak
    Klaudia Piekielniak in OpenRoads | OpenSite > OpenRoads | OpenSite Wiki (Polski):
    Webinary

    Tutaj znajdą Państwo linki do zaplanowanych i już odbytych webinarów czy spotkań SIG/CC. 

    ________________

    Read more.
    • 3 hours ago
    • More
    • Cancel
  • Kevin van Haaren
    Kevin van Haaren replied to this:
    JosephCyriac
    JosephCyriac asked a question in ProjectWise > ProjectWise PowerShell Extensions Forum:
    PowerShell Create new ProjectWise folder from template and Excell file

    New-PWLogin
    
    $outfile = Get-TablesFromXLSXWorkbook -InputFileName 'C:\Users\joseph\Desktop\OutFile.xlsx '
    
    foreach($row in $outfile.rows)	
    {
        New-PWRichProjectFromTemplate -newFolderPathName $row.FolderPath -NewProjectName $row.FolderName -Template...

    Read more.
    • 1 day ago
    • More
    • Cancel
    • View more replies
    • Kevin van Haaren Kevin van Haaren in reply to JosephCyriac

      Are you getting the "Script execution completed." message?

      • 3 hours ago
      • More
      • Cancel
    • Kevin van Haaren Kevin van Haaren in reply to Brian Flaherty

      I'm not seeing a pwps_dab 23.3.0.00 on PowerShell Gallery

      With version 23.2.6.0 I found when using -NewFolderPathName the path specified has to be the entire path to the work area, not the path to folder above the work area. You still need to specify...

      Read more.
      • 2 hours ago
      • More
      • Cancel