• Holly Herring
    Holly Herring edited this:
    Kevin McDonald
    Kevin McDonald in OpenRoads | OpenSite > OpenRoads | OpenSite Wiki:
    Video: Stack Cross Sections on Sheet from Top to Bottom
    Product(s): OpenRoads Designer Version(s): 10.08.01.33+ Area:  Drawing Production

    This video demonstrates using OpenRoads Designer to create a cross section set which stacks cross sections on your sheet starting at the top of the page moving downward...

    Read more.
    • 8 hours ago
    • More
    • Cancel
  • Jon Summers
    Jon Summers suggested an answer to this:
    Sakthi Karuna
    Sakthi Karuna asked a question in MicroStation > MicroStation Forum:
    How to run a Report on location of cells and place as a Table

    How to run a Report on location of cells and place as a Table - MicroStation Wiki - MicroStation - Bentley Communities

    I tried the steps in above link to create a table of coordinates.

    When I click on the Item types, I am not able to go to next process...

    Read more.
    • 11 hours ago
    • More
    • Cancel
    • View more replies
    • Sakthi Karuna Sakthi Karuna

      Hi,

      Thanks for the reply

      Yes, I have tried it but it doesn't help.

      I guess it is due to some background settings, because if I do the same procedure in other machine it is working fine.

      • 10 hours ago
      • More
      • Cancel
    • Jon Summers Jon Summers Suggested Answer
      Sakthi Karuna said:
      How to run a Report on location of cells and place as a Table

      A Report can include almost any DGN property.  MicroStation Help is confusing because it implies that a Report can be only about Item Types, whereas you don't need any Item...

      Read more.
      • 8 hours ago
      • More
      • Cancel
  • jcallicott
    jcallicott in ProjectWise > ProjectWise Design Integration Forum:
    ProjectWise Error -2147467259?

    Greetings,

    This morning, when attempting to open a file from one of our competitors' PW system, I received an error with a truly unique error number:

    I could not even look up this error number with the PW user Tools - it simply won't accept such a...

    Read more.
    • 8 hours ago
    • More
    • Cancel
    • Kevin van Haaren Kevin van Haaren

      Frequently when you get an error number you can't find in the User Tools (especially one that is a very large negative number) it's actually a Windows error. Sometimes it's better to convert to a hex number and search on that error too. Converting...

      Read more.
      • 3 hours ago
      • More
      • Cancel
  • Satish Saptasagar
    Satish Saptasagar in OpenUtilities > OpenUtilities Wiki:
    How to add Additional Part Number to a Primary Part Number in OpenUtilities Substation

    -

      Product(s): OpenUtilties Substation CONNECT Edition   Version(s):  10.00.XX.XX to 10.15.XX.XX   Environment:  NA   Area:  Component Management   Subarea:  Parts Database Manager

    Background:

    Usually users might have requirement where they...

    Read more.
    • 8 hours ago
    • More
    • Cancel
  • Pinky Shee
    Pinky Shee edited this:
    Pinky Shee
    Pinky Shee in ProjectWise > ProjectWise Design Review Wiki:
    ArcGIS Feature Service Support

    The Map Layers widget has added the support of a new GIS data type, ESRI ArcGIS FeatureService. This type of format is very common in the GIS world. The ArcGIS FeatureService often contains sub-layers. In this specific case, our UI allows selecting the...

    Read more.
    • 1 month ago
    • More
    • Cancel
  • Jutta Eisenhauer
    Jutta Eisenhauer edited this:
    Jutta Eisenhauer
    Jutta Eisenhauer in Licensing, Cloud and Web Services > Licensing and Activation Wiki (Deutsch):
    'Script Error' oder 'Page Expired Error' oder 'Seite abgelaufen' beim CONNECTION Client Login

    Der Grund für diese Probleme liegt in einer Abhängigkeit vom Internet Explorer in älteren Versionen des CONNECTION Client und in den lokalen Computereinstellungen für den Internet Explorer, die in einigen Fällen zu einem Konflikt führen können....

    Read more.
    • 8 hours ago
    • More
    • Cancel
  • Larry Abla
    Larry Abla suggested an answer to this:
    Saurabh SINGH
    Saurabh SINGH asked a question in OpenFlows | Water Infrastructure > OpenFlows | Water Infrastructure Forum:
    HGL outside the pipe in CivilStorm when using GVF- Rational method with Design as calculation option

    HGL outside the pipe in CivilStorm when using GVF- Rational method with Design as calculation type.

    In my understanding this above screenshot represent undersized network. However, this should not happen as the calculation type is set to "Design"....

    Read more.
    • 11 hours ago
    • More
    • Cancel
    • Larry Abla Larry Abla Suggested Answer

      Hello Saurabh Singh,

      Are you getting any User Notifications about HGL or Slope?

      This wiki article on Constraint-based Design could help - Troubleshooting Constraint Based Design Results

      It could also be that even if the flow in the pipe is less than the...

      Read more.
      • 8 hours ago
      • More
      • Cancel
  • Vincas Razma
    Vincas Razma edited this:
    Vytautas Barkauskas
    Vytautas Barkauskas in SYNCHRO Construction Solution > SYNCHRO Field Wiki:
    3.4.50 (October, 2023)

    SYNCHRO Field iOS 3.4.50 (October 30th, 2023)

    • Added support for forms with survey control.
    • Added full support for forms transition approval workflows.
    • Photo and video capture improvements.
    • Other bug fixes and stability improvements.

    SYNCHRO Field Android...

    Read more.
    • 7 days ago
    • More
    • Cancel
  • Andrew Pagels
    Andrew Pagels replied to this:
    GANDHE PUSHYAMITHRA
    GANDHE PUSHYAMITHRA asked a question in RAM | STAAD | ADINA > RAM | STAAD Forum:
    Creating group in in staad.pro connect edition

    Please explain set by step procedure to create grops in staad.pro connect edition. 

    • over 4 years ago
    • More
    • Cancel
    • View more replies
    • Modestas Modestas Verified Answer

      Groups in STAAD.Pro CE can be created by going to Utilities menu and clicking on the Groups icon in the Geometry Tools.

      • over 4 years ago
      • More
      • Cancel
    • Andrew Pagels Andrew Pagels in reply to Modestas

      What is the difference between a Node Assigned group, Beam Assigned group, and a Plate Assigned group?  Can beams and plates be added to Node Assigned groups?

      • 8 hours ago
      • More
      • Cancel
  • Abdi Musa
    Abdi Musa asked a question in RAM | STAAD | ADINA > RAM | STAAD Forum:
    Punching Check Error

    I have perimeter beams and columns. The slab edge, beam edge, and column edge on same line. RAM concept shows an error when checking punching.  But in the warning window, the program displays the design strip not on a slab.

    Any help? Thanks. 

          

    • 9 hours ago
    • More
    • Cancel
  • Brian Sawaska
    Brian Sawaska asked a question in OpenRoads | OpenSite > OpenRoads | OpenSite Forum:
    Point Features Station Offset Elevation Report in OpenRoads?

    How do I get the elevations to show up in the Point Features Station Offset Elevation Report in OpenRoads?

    I get the stations and coordinates, but nothing instructs me to identify the survey file.

    • 9 hours ago
    • More
    • Cancel
  • Thomas Warnasch
    Thomas Warnasch replied to this:
    Darin Rodberg
    Darin Rodberg asked a question in MicroStation > MicroStation Forum:
    Does anyone know why I can't change the priority of my references?

    Hi all,

    I'm working on a drawing in which I'm using a couple of point shapefiles produced by our surveyors to make an as-built. I need to be able to place cells and linework on top of the points in the shapefiles without obscuring the points. Normally...

    Read more.
    • over 4 years ago
    • More
    • Cancel
    • View more replies
    • Thomas Warnasch Thomas Warnasch

      I might be about four years late, but I had a similar issue.

      What solved my issue is updating the "Update Sequence".
      This is done by going to References -> Top left corner to "Settings" -> Update Sequence.

      In this window, put the...

      Read more.
      • 9 hours ago
      • More
      • Cancel
    • Lorys Lorys in reply to Thomas Warnasch

      Thats what I try first. Old school default methods first port of call always for me!

      • 3 hours ago
      • More
      • Cancel
  • Darin Rodberg
    Darin Rodberg and 2 others earned the Discussion Starter I achievement.
    Discussion Starter I
    • 9 hours ago
    • More
    • Cancel
  • Mike Dattilio
    Mike Dattilio suggested an answer to this:
    HVN
    HVN asked a question in AutoPIPE > AutoPIPE Forum:
    ASME B31.3 2022 edition

    We're doing a project that requires pipe stress analysis according ASME B31.3 2022 ediiton.

    First lines need to be analyzed in december. My current version (23.00.00.230) doesnt support B31.3. edition 2022. 

    Am I missing something?

    Can someone perhaps...

    Read more.
    • 10 hours ago
    • More
    • Cancel
    • Mike Dattilio Mike Dattilio Verified Answer

      Greetings HVN,

      Please see WIKI here, "3. How to update AutoPIPE with a new piping code or a new Code Compliance Calculations?", this will help explain things how a code is added to the program.

      Next, while reviewing the code itself, notice the...

      Read more.
      • 9 hours ago
      • More
      • Cancel
  • Deborah Gardiner
    Deborah Gardiner in Asset Reliability | AssetWise APM > Asset Reliability | AssetWise APM APM Blog:
    APM oData API 2023.11.02.2 Released

    APM oData API 2023.11.02.2 Released

    Readme

    • 9 hours ago
    • More
    • Cancel
  • Deborah Gardiner
    Deborah Gardiner edited this:
    Deborah Gardiner
    Deborah Gardiner in Asset Reliability | AssetWise APM > Asset Reliability | AssetWise APM Wiki:
    APM oData API
    APM oData API Documentation APM oData API Readme 2023.11.02.2 APM oData API Readme 2023.10.13.4

    APM oData API Readme 2023.9.25.1

    APM oData API Readme 2023.8.23.2

    APM oData API Readme 2023.8.9.1

    APM oData API Readme 2023.7.25.1

    APM oData API Readme... Read more.
    • over 1 year ago
    • More
    • Cancel
  • Deborah Gardiner
    Deborah Gardiner in Asset Reliability | AssetWise APM > Asset Reliability | AssetWise APM Files:
    PDF
    APM oData API Readme 2023.11.02.02

    New features and release notes for APM oData API v2023.11.02.02

    • 9 hours ago
    • More
    • Cancel
  • John Michael Callen
    John Michael Callen edited this:
    John Michael Callen
    John Michael Callen in iTwin IoT > iTwin IoT Wiki:
    Feature Release Notes

    This article will cover new features and product enhancements for the iTwin IoT software product. 

    November 2023 Features and Enhancements

    • Added additional filtering options within IoT Sensors Widget of Digital Twin Module. New filtering options include...
    Read more.
    • 1 month ago
    • More
    • Cancel
  • Miguel Navarrete
    Miguel Navarrete asked a question in GeoStudio | PLAXIS > GeoStudio | PLAXIS Forum:
    Have HSS small constitutive model the brick algorithm to simulate dynamic loads as earthquakes?

    Cudny & Truty (2020) "Refinement of the Hardening Soil model within the small strain range" described a problem with dynamic load using HSS model. Plaxis has the brick algorithm or other improvements to simulate dynamic load with this constitutive...

    Read more.
    • 9 hours ago
    • More
    • Cancel
    • Faseel Khan Faseel Khan Suggested Answer

      This paper that you referred to is talking about HSS model which was developed by Benz and coworkers. The PLAXIS HSsmall model uses the Hardin-Drnevich relationship in which the stress-strain curve for small strains can be adequately described by a simple...

      Read more.
      • 5 hours ago
      • More
      • Cancel
  • stuartw
    stuartw asked a question in MicroStation > MicroStation Forum:
    MS 2023 Model Copy errors/aborts

    Using the latest version of MS2023 if I try to 'model copy' 9 times out of 10 it hangs and then aborts, sending an error log to Bentley. U17 doesn't do this.

    Any one else having Model Copy issues?

    • 9 hours ago
    • More
    • Cancel