• Why is AECOsim Building Designer crashing?

    Vipul Jain
    Vipul Jain
    I work with Inox steel India , why is AECOsim Building Designer crashing on my PC?
    • over 1 year ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • How to add "RAW Data Object Width/Height/Length" to Instance Data Definition. For attachment to existing standard .dgn elements

    Stuart Travis
    Stuart Travis
    I have existing dgn elements and cells (not authored in AECOsim, no parts/family definitions). I am attaching my own user definitions as instance data. My question is how to add object dimension data to my user definition. Ideally I want to attach…
    • over 1 year ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • Customize The Detailing Symbol Style In The Place Callout Tools Dialog

    Shivam Soni
    Shivam Soni
    Product(s): OpenBuildings Designer Version(s): CONNECT Environment: N\A Area: Drawing Views Subarea: Drawing Seeds Problem Description The Detailing Symbol Style in the Place Callout tools…
    • over 1 year ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • OBD / AECOSIM Energy Simulator

    Abby Goh
    Abby Goh
    :i completely unable to see my model i Exported from OBD to Energy Simulator and SMART materials present in folder (C drive) but absent in Energy Sim Software (unable to change to SMART material)
    • over 3 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • AECOsim V8i SELECT series 6 Lagging and crashing

    Mark Inglis
    Mark Inglis
    Hi, Some of my models are running extremely slowly and after a while they crash and I have to abort. This isn't stopping work but its slowing it down significantly. I have one MC referenced in which has approximately 45 models of both 2D and 3D, I am…
    • over 3 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • Compatibility of OpenBuildings and AECOsim with Structural Synchronizer V11

    Arindam Roy
    Arindam Roy
    Product(s): OpenBuildings Designer, AECOsim Building Designer Version(s): CONNECT Edition Environment: N/A Area: General Subarea: N/A Problem With the new release of the Structural Synchronizer…
    • 2 months ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • Unable to launch OpenBuildings Designer due to errors in Microsoft .NET Framework and initializing SMC

    Arindam Roy
    Arindam Roy
    Product(s): OpenBuildings Designer, AECOsim Building Designer Version(s): CONNECT Edition, V8i Environment: N/A Area: General Subarea: Errors Problem Solution These issues might occur individually…
    • 2 months ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • Clarification required on user defined data set in aecosim

    Sreedhar D
    Sreedhar D
    Hi all We are using bentley aecosim, we add the element info by the help of dataset, and those details are not reflect in IMODEL & other computers, kindly advise us to resolve this issue Thanks
    • over 4 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • Section callout on the bottom

    Juan José Icaza
    Juan José Icaza
    I am using AECOsim CONNECT Edition update 4. Sometimes when activating the section callout, it appears in the bottom. I was expecting it on the top. How to I change this? I believe it is related to the way I creating the section. However, I would think…
    • over 4 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • Automating Updating Cached Views

    Steve Cocchi
    Steve Cocchi
    Product(s): AECOsim Building Designer Version(s): N\A Environment: N\A Area: Drawing Views Subarea: Output Problem I would like the cached views in my project to get updated automatically over…
    • over 4 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • The "Mark" Property On Structural Members Is Not Populating.

    Steve Cocchi
    Steve Cocchi
    Product(s): AECOsim Building Designer Version(s): CONNECT Edition Environment: N/A Area: Dataset and Content Subarea: Family/Part Problem The "Mark" property, when placing structural members…
    • over 4 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • How to Create Parametric Objects using CEL (Parametric)

    Satadal Dhar
    Satadal Dhar
    Product(s): AECOsim Building Designer Version(s): CONNECT Edition Update 3 and later Environment: N\A Area: Platform Tools Subarea: N\A Problem Description I would like to use CEL (Parametric…
    • over 4 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • Is Bentley Missing a Trick?

    Jide A.
    Jide A.
    Although my Architectural training was Pre-CAD Days, by the time I went back to do a Masters in Computing and Design it was possible as a student to gain access to free Bentley Microstation Software at the university. It was also possible to Purchase…
    • over 4 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • Create Display Set in Level Display window is not working

    Kristjan
    Kristjan
    Hello! I have used a lot right-click command "Create Display Set" in Level Display window in AECOsim Ss6 previously, but in AECOsim CONNECT edition Update 3 it seems to be broken. The option is still there and is clickable but nothing happens when clicked…
    • over 4 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • CREATE A SYSTEM FAMILY IN AECOSIM SAME AS REVIT

    Sreedhar D
    Sreedhar D
    For an example if we are creating a MEP family in revit we have an option connector then we can choose pipe connector, duct connector etc..., like same how we create MEP cells in aecosim with pipe connector help me to solve this issue Thanks
    • over 4 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • Working with Sketch Grids

    Steve Cocchi
    Steve Cocchi
    Product(s): AECOsim Building Designer Version(s): CONNECT Edition Environment: N\A Area: Grid Systems Subarea: Sketch Grids Background How can I create and save Sketch Grids?…
    • over 4 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • CONNECT Edition - Can't Deactivate CONNECT Advisor on start.

    Klaudia Piekielniak
    Klaudia Piekielniak
    Product(s): AECOsim Building Designer Version(s): CONNECT Edition Environment: N\A Area: General Subarea: Error Background I can not stop CONNECT Advisor from popping-up upon starting…
    • over 2 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • How can I create the 2d element array with variables?

    Joaquin
    Joaquin
    Hello, I can create elements array with 3d elements and variables. This is correct. See image. I can also create 2d elements with variables and constraints. Also this is correct. Then, I need to create 2d elements array, but I can't place the variable…
    • Answered
    • over 5 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • TFDIR_SETTING Points to an invalid path

    Satadal Dhar
    Satadal Dhar
    Product(s): AECOsim Building Designer Version(s): V8i and CONNECT Environment: N/A Area: Configuration Subarea: N/A Problem While opening AECOsim Building Designer, you might get an error saying…
    • over 5 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • Where is it "Edge Display " in mesh utilities of ABD CE update 3?

    Joaquin
    Joaquin
    Hello, I can't find the tool "Edge Display" in mesh utilities of ABD CE update 3 In the help Ribbon: Modeling>Mesh>Mesh Utiliies, but it does not exist. I remember that it was there in the update 1 or 2 How can I activate this tool in ABD CE update…
    • Answered
    • over 5 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • How to set fill color in architectural spaces

    Steve Cocchi
    Steve Cocchi
    Product(s): AECOsim Building Designer Version(s): CONNECT Edition Area: Drawing Views Subarea: Drawing Rules Problem How to set fill color in architectural spaces using display rules? Solution We can…
    • over 4 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • Language pack in ABD Connect Edition installation

    Joaquin
    Joaquin
    Hello, when ABD Connect Edition is installed you can install all the available Dataset (USA, NM, Spanish, Italian, German, etc). However, the language packs must be downloaded each one and installed separately, one by one. Is it planned in the future…
    • Answered
    • over 5 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • To get back the missing (ByLevel) description of Line Style

    Satadal Dhar
    Satadal Dhar
    Product(s): AECOsim Building Designer Version(s): CONNECT Edition Environment: N/A Area: Drafting Subarea: Attributes ByLevel is Missing If you find that the description (ByLevel) is missing…
    • over 5 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • CONNECT Edition - Reference files don't allow color override setting

    Larry Abla
    Larry Abla
    Product(s): AECOsim Building Designer Version(s): 10.03.00.40 Environment: Windows 10, Windows 8/8.1 Area: Reference Subarea: N\A Problem Description I want all reference files to display gray…
    • over 5 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • To Get Pipe Thickness Data

    Satadal Dhar
    Satadal Dhar
    Product(s): AECOsim Building Designer Version(s): 08.11.09.866 and above Environment: N\A Area: Plumbing Design Subarea: N\A Problem How to add pipe thickness information in pipes? Solution…
    • over 5 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
>