• How to fill out the "contact" tab in the COBie spreadsheet? | AECOsim Building Designer V8i

    Yehia Elsayed
    Yehia Elsayed
    Any idea where/how do i add the sales teams information in the model? So that when i export the COBie spreadsheet, the information is filled in the "contact" tab.
    • over 2 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • Developed cylindrical shape

    Xavi Torello Ciriano
    Xavi Torello Ciriano
    Could create a dynamic view of a cylinder showing the developed cylindrical shape?
    • over 3 years ago
    • Licensing, Cloud and Web Services
    • Licensing, Cloud and Web Services Forum
  • How to print multiple file in Aecosim?

    Antony Stalin LAWRENCE
    Antony Stalin LAWRENCE
    I Would like to print Multiple files in one go, is it possible in AECOsim? like Batchplot or Publish etc
    • over 3 years ago
    • Printing and Plotting
    • Printing and Plotting Forum
  • OpenBuildings Designer CONNECT Edition, Update 7 (v10.07.00.105)

    Jeff Ashley
    Jeff Ashley
    The OpenBuildings product team is pleased to announce the availability of OpenBuildings Designer CONNECT Edition, Update 7 (v10.07.00.105) through the Bentley CONNECT Center, Software Downloads portal, or the desktop CONNECTION Client. This release includes…
    • over 3 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Announcements
  • Does Anyone Ready to Help

    Muhammad ISMAIL
    Muhammad ISMAIL
    Hi Everyone i am in need of modeling a Precast I Beam Girder in Aecosim So i am here to ask Geniuos to help produce a cell which can be modified. as per length. kindly see attach sketch. the beam starts with skech 1 from support and say like after…
    • over 3 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • How to extract section along grids in aecosim

    MUHAMMAD ISMAIL
    MUHAMMAD ISMAIL
    Hi Does Antoine knows how to cut a section elevation along al radial grid. Regards
    • over 3 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • How to cut radial section

    MUHAMMAD ISMAIL
    MUHAMMAD ISMAIL
    Hi everyone Please share if you know how to cut a radial section in aecosim building designer.. Best regards Muhammad Ismail
    • over 3 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • How to draw a 2d section along a curved grid in openbuildings

    MUHAMMAD ISMAIL
    MUHAMMAD ISMAIL
    Hi Could someone please share the method of extracting 2d section on a curved grid. Best regards Muhammad Ismail
    • over 3 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • How to create Window in roof (not dormer) just window in roof. Similar to adding windows in wall.

    Jakub Szkaradzinski
    Jakub Szkaradzinski
    I would like to ask: How to create Window in roof (not dormer) just window in roof. Similar to adding windows in wall. I`ve seen this solution for a window dormer, but this is not what I'm looking for. Does it existing any easy way to add (roof window…
    • over 3 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • 急急急!!!OBD安装到StructuralSynchronizer停止不动是什么原因?求大神解答!

    Jinxing Lee
    Jinxing Lee
    • Answered
    • over 3 years ago
    • Bentley 中国优先社区
    • ◆ 建筑设计(OpenBuildings Designer / ABD,AES等)
  • ABD 悬停信息

    超 上官
    超 上官
    各位老师 : 通过C++写了悬停信息程序,并将.dll文件放在 C:\Program Files\Bentley\AECOsim CONNECT Edition\AECOsimBuildingDesigner\MdlSys\Required 目录下 发现确实能够显示悬停信息,但是它将ABD原始的悬停信息覆盖掉了.... 请问各位老师,怎么样可以显示我自己的 又不影响软件中自带的悬停信息?
    • over 3 years ago
    • Bentley 中国优先社区
    • ◆ 建筑设计(OpenBuildings Designer / ABD,AES等)
  • migrating files from AECOsim SS6 to OBD connect

    David Turner
    David Turner
    i need to import mechanical files from AECOsim SS6 to OBD connect Update 6 when i have tried copying the elements into the ODB file i get this message does this mean that pipework or ductwork modelled using the aecosim applications are not compatible…
    • Answered
    • over 3 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • Promoted view columns disappear

    Chris Dixon
    Chris Dixon
    Hi All Within a call-out structural columns show just as centre lines, if the view is demoted the columns display correctly, however any hatching will disappear Promoted View Demoted View Using OBD 5 Any suggestions Cheers Chris
    • over 3 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • MS render problem

    Ruan Jian 阮健
    Ruan Jian 阮健
    I customized the MS material rendering template using photographs , which photographs I downloaded from the Internet. After I customized it, I exported it to the .mat template, but after I imported it on other computers, the material of my customized…
    • Answered
    • over 3 years ago
    • Bentley 中国优先社区
    • ◆ 建筑设计(OpenBuildings Designer / ABD,AES等)
  • Equipment Position Plan AECOSIM Building Designer

    muhammad-shariq abbas
    muhammad-shariq abbas
    Dear all, Any one have form you experience working in the equipment position plan? I mean i have a 2d plot from 3Dplan, in which the equipments, instruments,fittings and electrical consumers are markes along with their positions. I had this 2D drawing…
    • over 3 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • How to move down a solid and rotate it such that it follow a surface

    KANG TENG TENG
    KANG TENG TENG
    I have a cyan cable trough "flying" above the white concrete. I need it to be moved down and follow the surface of the concrete. Q1: Is there any alternative solution to achieve this? I have used move + rotate to move the cyan trough to red trough location…
    • over 3 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • Customize The Detailing Symbol Style In The Place Callout Tools Dialog

    Shivam Soni
    Shivam Soni
    Product(s): OpenBuildings Designer Version(s): CONNECT Environment: N\A Area: Drawing Views Subarea: Drawing Seeds Problem Description The Detailing Symbol Style in the Place Callout tools…
    • over 1 year ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • Flujo de Trabajo Optimizado para producir archivos IFC con OpenBuildings Designer

    Eduardo Cortes
    Eduardo Cortes
    A continuación se detallan los pasos a seguir para trabajar en OpenBuildings Designer cuando el objetivo sea producir un IFC como resultado. 1 - Crear un nuevo plan de trabajo en OpenBuildings Designer. Desde la página de inicio de OpenBuildings tenemos…
    • over 3 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki (Español)
  • 3D Annotation and Export to IFC

    KANG TENG TENG
    KANG TENG TENG
    Hi all, I need to mark out chainage along an alignment line. The final result should looks like picture. After all chainage annotation is done, i need to export the line and annotation to IFC and view them in Revit. However all lines and annotation…
    • over 3 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • 安装CE版AECOsimBuildingDesigner update 3后,v8i版的AECOsimBuildingDesigner的风管命令不能用了

    BIN SUN
    BIN SUN
    如题,安装CE版AECOsimBuildingDesigner update 3后,v8i版的AECOsimBuildingDesigner的风管命令不能用了, CE版AECOsimBuildingDesigner 正常。可是我还想用v8i版的。把CE版和v8i版的都卸载后重装v8i版的也不行,请问该怎么办?能回复v8i版的ABD吗?
    • over 3 years ago
    • Bentley 中国优先社区
    • ◆ 建筑设计(OpenBuildings Designer / ABD,AES等)
  • Why the measure volume result is different between V8i version and CE version

    Lynn
    Lynn
    Hi Dear all, I would like to ask the measurement question that I discover in these two versions. (AECOsim V8i SS6 and OpenBuildings CE 10050049en ) This situation is happened on my manager doing double-check the model volume. I was used AECOsim…
    • over 3 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • Running a macro using batch process in OpenBuildingsDesigner CONNECT Edition

    Shivam Soni
    Shivam Soni
    Product(s): OpenBuildings Designer, AECOsim Building Designer Version(s): CONNECT Edition, V8i Environment: N/A Area: Customization Subarea: Macro-Batch Process Problem I have my batch process…
    • over 1 year ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • [C++] Using libzippp libary in MDL-App

    Eugen Gebert
    Eugen Gebert
    Hey Guys, i want to use an extern libary, in this case the libzippp libary, to work with zip-files. I'm working with Visual Studio 2017 and I linked every libs staticly in the .mke file: LINKER_LIBRARIES = $(mdlLibs)bentley.lib \ $(mdlLibs)mdlbltin…
    • over 3 years ago
    • MicroStation Programming
    • MicroStation Programming Forum
  • 关于ADB ce U3崩溃的问题

    Ruan Jian 阮健
    Ruan Jian 阮健
    我重新安装了系统,安装了ABD CE UP3,在使用压型板命令时,软件出现崩溃情况,显示为如下界面,请那位专家能帮我解决这个问题
    • over 3 years ago
    • Bentley 中国优先社区
    • ◆ 建筑设计(OpenBuildings Designer / ABD,AES等)
  • How to Sweep then Convert Bspline Curve to solid ?

    KANG TENG TENG
    KANG TENG TENG
    Rail Turnout.dgn I am difficulty trying to sweep the two rail profiles along alignment line (green line). software crash every single time. (primary question) I did it sweep successfully on a much simpler shape, but after that i am stuck with bspline…
    • Answered
    • over 3 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
<>