CADD Operator: MicroStation and AutoCAD
Rhea Engineers & Consultants, Inc. – Valencia, PA
Company
Founded in Pittsburgh, Pennsylvania in 2001, Rhea Engineers & Consultants, Inc. (Rhea) is a 100 percent woman-owned professional corporation providing…
Product(s):
StormCAD, SewerCAD, SewerGEMS, CivilStorm, WaterCAD, WaterGEMS, HAMMER
Version(s):
08.11.05.58 +, 10.XX.XX.XX
Area:
Layout and Input
Problem
How can I ensure that the correct units are used and the elements…
MicroStation, InRoads and AECOsim BD with UHD and Windows 8.1 or 10
UHD, High DPI, high resolution, 4K, DPI Scaling, dpiAware, side-by-side configuration, manifest, AutoCAD,
If you have display with very high resolution, ultra HD (UHD), or 4K, you…
This tool is for edit MXROAD genio file format cross section and InRoads pen code format cross section on Autocad. 720p HD format video is available at,
http://www.youtube.com/watch?v=eWD-tBKia28
HELP!
Is your company a victim of Bentley‘s software licensing policies?
We used to be happy with the SELECT subscription‘s Trust Licensing program until about two and a half years ago when we learned about the „bucket method“ of license usage …
Is your company a victim of Bentleys software licensing policies.zip
Steven,
InRoads on AutoCAD in a 64 bit operating system is not supported. This is noted in both the Requirements and Known Issues of the readme. I apologize for any inconvenience.
Thanks,
Jason Smithey
My company is trying to develop a way to utilize the intelligent Civil 3D Pipe Networks, but we are required by most of our clients to display all of our data in a 3D model in Microstation. I am trying to create a workflow to convert Civil 3D 2012 Pipe…
InRoads Group V08.09.03.06 is basically a service pack. They are no longer referred to as service packs because you can now install them by themselves without requiring previous builds as was the case in older versions (e.g. InRoads V08.05.00.00 had to…
Chuck,
We are not aware of any AutoCAD configuration variables that can be used in Project Defaults. I double checked with development and it was confirmed that the code only looks for the MicroStation configuration variables. If desired, please…
Hi Chuck,
The list is showing 2008/2009 because they use one .ARX file to start and the 2010/2011 uses a different .ARX file.
As an example using 2008/2009 AutoCAD
• In AutoCAD, we look at HKEY_CLASSES_ROOT\ CLSID\{28B7AA99-C0F9-4C47-995E-8A8D729603A1…
Artem,
There has been at least one fix made to collision free text for the next major release of the software. Though not ideal, you may have to manually move the text with MicroStation. You may want to send your data to support to confirm that…
David:
InRoads 8.9.2.16 is XM, not 8i. So we are not there either.
Are you telling me that as far as you know, InRoads Survey will not write linework using bylayer?
We have multiple clients with varying standards, so jumping between…
Does Bentley InRoads Site V8i currently support the AutoCAD 2013 platform? If not, when is this likely to occur and is there a commitment to continue supporting progressive AutoCAD platforms in future?
Running InRoads 8.9.2.16 inside of AutoCAD 2008. When writing Survey Data to Graphics, the linework is taking on the bylayer linestyles instead of using the bylayer settings. If I set a linestyle, it uses that linestyle, even if the layer's linestyle…
Hi, my company is about to make the leap and buy one of the Bentley Civil packages. I'm the only one in the office familiar with Bentley, and I have never used anything other than plain old MicroStation. I've requested information from and had come contact…