• Beam design with axial force and Biaxial Moment - Side face reinforcement for Column detailing

    Ranjana Shinde
    Ranjana Shinde
    ​​ Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam design Original…
    • 23 days ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • RAM Concept: As (after reduction for development length)

    Bowen Shen
    Bowen Shen
    I am working on one-way slab supported by mild reinforced concrete beams. The beam is trimmed as a T-section with flange width of 99". I drew #4 at 18" (full slab area) on top of the slab in the direction parallel to the beam, which make 5-#4 (total As…
    • 1 month ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Axial force on non-PT mild reinforced beams under dead and live load cases

    Bowen Shen
    Bowen Shen
    I am modeling a one-way concrete slab. PT girders are in perimeter and in the north-south direction, and mild reinforced infill concrete beam in the east-west direction. When I checked mild reinforced concrete design, I noticed the cross-section at end…
    • 2 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • SCBF's Beam design using RAM Structural System

    Katy Briggs
    Katy Briggs
    Hi I am designing a steel building using SCBF's and I was wondering if there is any procedure or way to check the beams inside RAM at the SCBF's per the seismic provisions (ASCE 341-10 Section F2.3(i) and (ii)) ? I know RAM checks for the required column…
    • 2 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Extract beam maximum dead and live loads

    Carlos Villegas
    Carlos Villegas
    Hi, I am trying to export a csv or excel file where I can see the maximum Dead and Live/Roof live load moments in each beam. I need to obtain them unfactored to post-process them in excel. The table would simply have the beam label, Md and ML. I've been…
    • 3 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Unknown Unreducible DL being applied to beams

    Ryan Hollenbeck
    Ryan Hollenbeck
    I have a location where two deck types meet, one with a roof loading and the other with a floor loading. There is an odd line load being applied in the analysis that is greatly affecting the design on my beams and columns. I cannot see to find the source…
    • Answered
    • 3 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Composite beam with 2 deck types

    Carlos Villegas
    Carlos Villegas
    Hi, I am modelling a beam with a change of deck along the length of the beam (half of the beam has a W2+3.5" verco deck, and the other half has a W2+2" deck). I read this response: Effects of Changing Deck Type - RAM | STAAD | ADINA Wiki - RAM | STAAD…
    • Answered
    • 4 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Beam failure in RCDC

    NAUSHAD KHAN
    NAUSHAD KHAN
    Hey I am also getting the same problem as a new beginner I didn't understood the offset removing answer ( communities.bentley.com/.../staad-rcdc---beam-bm-detailing-failure) how do I remove offset I have already created mesh and now every beam got divided…
    • 4 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • BEAMS ARE NOT LOADING IN RCDC

    NAUSHAD KHAN
    NAUSHAD KHAN
    I Have created a model in staadpro and analyzed it and I also used mesh tool for slab design now after creating mesh the beams are divided into small length ..... no problem till now but when I import this model in RCDC the beams are not loading (i think…
    • 4 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Beam Design for Biaxial Moment

    Abhisek M
    Abhisek M
    Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam Design Original Author: Abhisek Mandal…
    • 5 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • Sway Shear Calculation in STAAD

    Abhisek M
    Abhisek M
    Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Design Subarea: Concrete Design Is13920 Original Author: Abhisek Mandal, Bentley Technical Support…
    • 6 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • RAM Concrete Beam Design - Design Warning for Flexural Reinforcement

    Jared Warren
    Jared Warren
    I have an 8"x16" concrete beam and in the end span of a multi-span condition, it says the bottom flexural beam reinforcement fails code limit by 1 bar. I have 2-#5 bars currently for all spans and for every other span, this is adequate and meets all code…
    • 6 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • How do I get around the RCDC's mandatory three bars?

    Rahul Brijpuriya
    Rahul Brijpuriya
    While design beam RCDC provide min 3 no of bars in the moment area how to bypass this check .There should be option in the RCDC to consider or not to consider this clause ?
    • 9 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Detailing of beams with different depths in RCDC

    Abhisek M
    Abhisek M
    ​​ Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam design Original…
    • 9 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • Include torsion in beam design as per IS456

    Modestas
    Modestas
    Applies To Product(s): STAAD Advanced Concrete Design Version(s): All Environment: N/A Area: Concrete Design Subarea: IS 456:2000 Original Author: Abhisek Mandal Bentley…
    • 5 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • Why IS Code 800-2007 LSD fails Ratio INFINITY, while AISC 360-10 ASD passed Beam with Ratio 0.44? Taper beam

    Arun Chugh
    Arun Chugh
    1) Design check by IS Code 800-2007 LSD fails gives result of Bending Ratio = “INFINITY”, which passes with AISC 360-10 ASD Ratio 0.44! Also IS 800 code output does not give any ratio in both major, minor axis! 2) Is this 12 mm Flange thickness is critical…
    • over 1 year ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • DEPTH OF BEAM SHALL PREFERABLY BE LESS THAN THE 1/4TH OF CLEAR SPAN

    Abhisek M
    Abhisek M
    Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Design Subarea: Concrete Design Is13920 Original Author: Abhisek Mandal, Bentley Technical Support…
    • 6 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • WARNING BEAM CODE RECOMMENDS THAT WIDTH/DEPTH > 0.3

    Abhisek M
    Abhisek M
    Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Design Subarea: Concrete Design Is13920 Original Author: Abhisek Mandal, Bentley Technical Support…
    • 6 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • How to get the max and min forces in each member ?

    Lt.Col. Parmar
    Lt.Col. Parmar
    How to get the max and min forces in each member ? Not to get the max of a selected group. need to get the maxm forces of each members (beams/column)
    • over 1 year ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • RAM Elements existing PEMB analysis always fails

    Jack Worline
    Jack Worline
    We often need to analyze existing PEMB structures and when only existing loads are applied the structure still fails. We have used the MBMA special considerations option in our design and that does not seem to help. What are we missing? Is there another…
    • over 1 year ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • hello everyone

    Sushant Kumar
    Sushant Kumar
    hello everyone,i am getting warning, can anyone help me out in removing those warning. warning are- 1.WARNING:Section fails while detailing 2.WARNING:Section fails while designing section: 3. WARNING:Reinforcement % exceeds maximum limit
    • over 1 year ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Does RCDC calculates moment capacity for sway shear calculations as per rectangular section or flanged section for beam?

    DSANJU
    DSANJU
    Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam design Original Author: SANJIB DAS…
    • over 1 year ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • Uplift point loads in my model are not being considered by the ram beam design module

    Kyle Gerard
    Kyle Gerard
    I have a building with screen wall loads on the roof. These loads act as a couple with the main post and the kicker having reactions in opposite directions. When I add these loads to the ram model, ram beam module is only considering the downward gravity…
    • over 1 year ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Customized curtailment provision in RCDC?

    Abhisek M
    Abhisek M
    Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam Design Original Author: Aaradhya Rahate…
    • over 1 year ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • Asv required for is greater than Asv provided.

    Aaradhya Rahate
    Aaradhya Rahate
    Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam Design Original Author: Aaradhya Rahate…
    • over 1 year ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
>