• Configuration Tips - Cell Libraries

    Marc Thomas
    Marc Thomas
    Four variables will be covered here: MS_CELL MS_CELLLIST MS_CELLOUT MS_CELLSELECTORDIR The delivered standards.cfg includes the lines: MS_CELL > $(_USTN_ORGANIZATION)cell/ # Cell libraries MS_CELLOUT = $(_USTN_ORGANIZATION)cell/ # Cell…
    • 4 months ago
    • Peer Blogs
    • Looking under the bonnet...
  • Proper .cfg Settings for network Configuration in Update 10?

    Paul MacKnight
    Paul MacKnight
    I'm having difficulty finding the answer to my question digging through the forums and documentation, and I don't have access to the Configuration Explorer software to verify on my own. I have a compounded issue where, in order to help some of our users…
    • 3 months ago
    • OpenBuildings | AECOsim | Speedikon
    • Energy Simulation Forum
  • MicroStation Command Line Options And Switches

    Jayson Perry
    Jayson Perry
    Product: MicroStation Version: V8, XM, V8i, CONNECT, 2023 Environment: N\A Area: Administration Subarea: N\A Command Line Parameters The easiest and most reliable way to determine which command…
    • 3 months ago
    • MicroStation
    • MicroStation Wiki
  • Configure Custom Configuration in the ProStructures using Manage Configuration.

    Vyanktesh Nama
    Vyanktesh Nama
    Product(s): ProStructures Version(s): CONNECT Edition ( 10.07.00.79 ) & Above Area: Setup & Customization Subarea: Configuration Setup Original Author: Vyanktesh Nama, Bentley Product Advantage Group …
    • 11 months ago
    • ProStructures
    • ProStructures Wiki
  • Configuration Tips - Manage Configuration Utility

    Marc Thomas
    Marc Thomas
    From MicroStation Update 17 we include the new Manage Configuration utility. Further updates to the utility were made from Update 17.2, see below. This enables MicroStation to switch between multiple configurations allowing further control and separation…
    • 3 months ago
    • Peer Blogs
    • Looking under the bonnet...
  • Using It! - Admin reports, AKA listing your stuff!

    Marc Thomas
    Marc Thomas
    My colleague Shawn McGaffick wrote these four blogs on some of the useful reports that administrators or project leads can run on their data. Reporting for CAD Administrators: Cell Count Reports Reporting for CAD Administrators: Working Units, Scales…
    • over 1 year ago
    • Peer Blogs
    • Looking under the bonnet...
  • OpenBuildings Speedikon Installation and Configuration

    Johannes Lerch
    Johannes Lerch
    Product(s): OpenBuildings Speedikon Version(s): CONNECT Edition Updates Area: Installation Subarea: N/A First, carefully read the installation and configuration instructions in the Readme and the Forum…
    • over 1 year ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • Configuring ProStructures to read configuration from custom location other than default location.

    Vyanktesh Nama
    Vyanktesh Nama
    Product(s): ProStructures Version(s): CONNECT Edition ( 10.06.01.59 ) & Below Area: Setup & Customization Subarea: Configuration Setup Original Author: Sandip Kar, Bentley Product Advantage Group …
    • 11 months ago
    • ProStructures
    • ProStructures Wiki
  • Migrating custom content from AECOsim Building Designer SS6 to a current OpenBuildings Designer version

    Marc Thomas
    Marc Thomas
    Product(s): OpenBuildings Designer Version(s): CONNECT Edition Area: Datasets and content Subarea: Migration/Upgrade This article focuses on the migration of project and customized dataset content. The…
    • over 2 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • VBA - A general purpose autorun macro

    Marc Thomas
    Marc Thomas
    In Adding information to the MicroStation Title Bar an autorun macro adds useful information to the application window title bar on file open or model close. This macro can also be used to run any other actions appropriate to file open or model close…
    • over 2 years ago
    • Peer Blogs
    • Looking under the bonnet...
  • Using It! - Add Frequent Tools or Places to the Quick Access Toolbar

    Marc Thomas
    Marc Thomas
    Like most Ribbon UI applications the Quick Access Toolbar (QAT) can be customized, before stating to explore this consider where any customizations will be stored. The default is in personal.dgnlib and will only be available to the person who adds the…
    • over 2 years ago
    • Peer Blogs
    • Looking under the bonnet...
  • Site Standards #00 - The Standards.cfg file

    Marc Thomas
    Marc Thomas
    Out of the box we deliver C:\ProgramData\Bentley\<applicationName>\WorkSpace\Standards\standards.cfg. This file lists a series of configuration variables that add paths to some of the sub-folders of ...\Workspace\Standards\ The list is fairly short…
    • over 9 years ago
    • Peer Blogs
    • Looking under the bonnet...
  • How to Deploy a Shared WorkSpace in BRCM CONNECT Edition

    Vikrant Kale
    Vikrant Kale
    Product(s): Bentley Raceway and Cable Management Version(s): 10.03.00.25 Environment: N/A Area: Installation Configuration Subarea: N/A Background There are different methods to store a workspace configuration…
    • over 4 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • Windows - Renaming multiple items

    Marc Thomas
    Marc Thomas
    This is a handy tip for configuration management in Windows 10. If you select dissimilar items in Windows File Explorer, in this example, a WorkSpace folder and it's CFG file, copying them obviously results in <file/foldername> - Copy.xxx, etc. However…
    • over 4 years ago
    • Peer Blogs
    • Looking under the bonnet...
  • How can I limit OpenBuildings Designer to use only my custom level libraries?

    Marc Thomas
    Marc Thomas
    Product(s): OpenBuildings Designer Version(s): CONNECT Edition Environment: N/A Area: Configuration Subarea: Levels Problem I have recently migrated from AECOsim Building Designer v81 SELECTseries6…
    • over 2 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • Configuration Tips - Adding information to the MicroStation Title Bar

    Marc Thomas
    Marc Thomas
    Background While working in practice and as a freelance consultant, one of my first questions in response to a user's problem, typically "why are all my references missing and showing up red", would be which project (now WorkSet) are you in (perhaps…
    • 3 months ago
    • Peer Blogs
    • Looking under the bonnet...
  • Upgrading to MicroStation CONNECT Edition

    Henk Ligtvoet
    Henk Ligtvoet
    Product: MicroStation Version: CONNECT Environment: N\A Area: Installation Subarea: General Background The intention of this Wiki is to give a CAD Manager or Site Admin a more comprehensive…
    • over 2 years ago
    • MicroStation
    • MicroStation Wiki
  • Setting Up the MicroStation CONNECT Workspace on a Network.

    Marc Thomas
    Marc Thomas
    Product: MicroStation Version: CONNECT Update 7 and newer Environment: N\A Area: Configuration Subarea: Workspaces This article covers the process for establishing a network workspace for MicroStation…
    • over 5 years ago
    • MicroStation
    • MicroStation Wiki
  • Configuration Tips - DGNLIBs

    Marc Thomas
    Marc Thomas
    This is an updated version of an earlier V8i 101 article. Paths have been changes to MicroStation 2023. (In previous versions installed paths follow the pattern C:\Program Files\Bentley\MicroStation CONNECT Edition\MicroStation\. Previous paths are…
    • 1 month ago
    • Peer Blogs
    • Looking under the bonnet...
  • Configuration Tips : Should I edit ConfigurationSetup.cfg?

    Marc Thomas
    Marc Thomas
    [Update November 2023] From MicroStation 2023 and OpenX 2023 products onwards, we have introduced the Manage Configuration Utility that creates connections to one or more configurations, please follow the link for full details. This results in ConfigurationSetup…
    • 1 month ago
    • Peer Blogs
    • Looking under the bonnet...
  • Configuration Tips : Where should I keep my DGNWS files?

    Marc Thomas
    Marc Thomas
    The DGNWS file, full name DGN WorkSet file, is very important. It contains WorkSet properties, custom properties, WorkSet sheet index, and the WorkSet Link Set. Each of these, other than the sheet index, involves some initial data input. As a project…
    • over 6 years ago
    • Peer Blogs
    • Looking under the bonnet...
  • Configuration Tips : Reference file variables

    Marc Thomas
    Marc Thomas
    The following tips are valid for V8i applications, the variables mentioned have not changed in CONNECT Edition. From MicroStation help: When MicroStation opens a DGN file, it searches for DGN files that contain attached references as follows: …
    • over 6 years ago
    • Peer Blogs
    • Looking under the bonnet...
  • CONNECT Edition - Custom Configuration Guides

    Yvonne Lohse
    Yvonne Lohse
    Product(s): MicroStation Version(s): 10.06.00.38 Environment: N/A Area: Configuration Subarea: Workspaces The following blogs posts describe the creation of a Custom Configuration for MicroStation…
    • over 4 years ago
    • MicroStation
    • MicroStation Wiki
  • CONNECT Edition - Configuration : Customization Guides

    Marc Thomas
    Marc Thomas
    Product(s): AECOsim Building Designer Version(s): 10.00.00.154 Environment: N/A Area: Configuration Subarea: Custom Configuration The following blogs posts describe the creation of a Custom Configuration…
    • over 6 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • CONNECT Edition - Custom Configuration - Part 4 : Standards CFG File Contents

    Marc Thomas
    Marc Thomas
    As discussed in Part 3 , Standards can be applied at all configuration levels. As delivered Standards content is configured: At the Organization level by: C:\ProgramData\Bentley\MicroStation CONNECT Edition\Configuration\Organization\standards.cfg…
    • over 6 years ago
    • Peer Blogs
    • Looking under the bonnet...
>