• DataGroups Custom Location

    Adrian Hałat
    Adrian Hałat
    Hi, In our company we created custom location for OBD standards. In WorkSets we added path to our custom Dataset. Everything works fine except DataGroup Catalogs and System included in Dataset. In Definition editor all roots are still directed to our…
    • 7 months ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • AECOsim Building Designer CONNECT Edition - Creacion de Atributos Personalizados

    Eduardo Cortes
    Eduardo Cortes
    En este video se explica como crear Atributos Personalizados y asignarselos a los elementos correspondientes en AECOsim Building Designer CONNECT Edition.
    • over 5 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki (Español)
  • AECOsim - Auslesen von Geometrie Daten über Datagroup Explorer ist nicht möglich

    Fritz Galuschka
    Fritz Galuschka
    Fundament als Freiform erstellt - Auslesen von Geometrie Daten über Datagroup Explorer ist nicht möglich - dringend da Produktion gestoppt ist! - bitte um eine kurzfristige Lösung Fundament als Freiform erzeugt und über Instanzdaten hinzufügen in Datagroup…
    • Answered
    • over 6 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon - Forum (Deutsch)
  • Schlitz- und Durchbruchsplanung mit PC Studio Zellen - 2D Plan Darstellung mit gefüllten Flächen

    Parametric Platform
    Parametric Platform
    erforderliche 2D Darstellung von Wand- und Deckendurchbrüchen in den Werkplänen: 2D Darstellung der AECOsim PC Studio Zelle/ Durchbrüche: um die erfoderliche Darstellung zu erreichen muss man im PC Studio im Model Segment Plan2d gefüllte Flächen…
    • over 6 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon - Forum (Deutsch)
  • Como convertir elementos CAD en objetos BIM con AECOsim Building Designer

    Johannes Lerch
    Johannes Lerch
    1 – Abrir el fichero CAD con AECOsim Building Designer. En la ventana de dialogo de Abrir Fichero tenemos que elegir un proyecto que esté vinculado al Dataset que queremos utilizar (por ejemplo, el Neutral Metric, llamado Dataset_NM). Podemos elegir…
    • over 6 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki (Español)
  • Grupo de Datos - AECOsim Building Designer

    Eduardo Cortes
    Eduardo Cortes
    Grupo de Datos - AECOsim Building Designer
    • over 7 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki (Español)
  • Introducción a los Espacios de Trabajo de AECOsim Building Designer

    Eduardo Cortes
    Eduardo Cortes
    ¿Cómo funcionan los espacios de trabajo en AECOsim Building Designer? Los Espacios de trabajo están organizados principalmente en 3 niveles: Sistema, Empresa y Proyecto . Cada uno de ellos incluye una serie de definiciones que pertenecen a un nivel…
    • over 7 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki (Español)
  • AECOsim Building Designer

    Eduardo Cortes
    Eduardo Cortes
    AECOsim Building Designer es el Producto BIM de Bentley que incluye herramientas para el diseño de Arquitectura, Estructuras, Instalaciones Mecánicas y Eléctricas en una sola aplicacion y con un unico interfaz. Es la evolución de las aplicaciones disciplinares…
    • over 9 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki (Español)
  • RE: insulation hatch

    Marc Thomas
    Marc Thomas
    In Dataset Explorer copy the slab part to your project dataset, rename it with the suffix _Insulation. In the Cut Patterns definition: Tick in the Pattern column Change the Pattern type to Patterning Set the pattern cell to 'baten' (this should…
    • over 9 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • Updating/Migrating SS4 Datasets to SS5

    Larry Abla
    Larry Abla
    Applies To Product(s): AECOsim Building Designer V8i Version(s): 08.11.09.735 (SS5 RC, will apply to Commercial Release) Environment: N/A Area: Dataset Subarea: Migration/Utilities…
    • over 6 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • Updating/Migrating SS3 Datasets to SS4

    Larry Abla
    Larry Abla
    Applies To Product(s): AECOsim Building Designer V8i Version(s): 08.11.09.593 Environment: N/A Area: Dataset Subarea: Migration/Utilities Original Author: Marc Thomas…
    • over 6 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • Circuit Reference changed after using "Add additional number of poles for panels" Wiki

    GLOVELY
    GLOVELY
    I followed the "Add additional number of poles for panels" Guide and a while later noticed that when I was in Cable Manager > Panel Schedule the circuit name did not agree with panel slot in the Schedule window. see fig 1.. Has anybody else had this problem…
    • over 11 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • UK Dataset IFC extended content

    Marc Thomas
    Marc Thomas
    Is there a particular reason why this IFC section in the updated GB Dataset PCF has been set to process at the user level? #====================================================================== # Extended Dataset Content: #=======================…
    • over 11 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • Adding Definitions to Exisiting Catalog Items

    Mark Holloway
    Mark Holloway
    I'm trying to add new definition fields to exisitng catalog items. In this case I want to add a specific property to Walls. I've created a new definition in Definition Editor and assigned it to the Walls catalog item in Catalog Editor. When I place…
    • over 10 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • Changing/Updating Curtian Walls and windows

    Scott Croix
    Scott Croix
    Several months ago I was shown how to change the levels that are in the curtain walls and Windows. Now there is a issue with that level that was changed. I can't remember the steps to go to change it the level. I have already went in through the Dataset…
    • over 15 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • Re: Moving to SS4

    Marc Thomas
    Marc Thomas
    Hi Rob, This is an outline of the steps required when moving from SS3 to SS4, I'll be adding more detail in a technote shortly: 1. Create a new network location for your workspace and dataset in parallel to the existing ss3 dataset; e.g., W:\V8i_SS4…
    • over 10 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • Bentleys Content Options

    HJM
    HJM
    Anyone, We have a client requesting Bentley BIM, eventually AECOSim and I’m trying to get a handle on the different Bentleys content options. what works with the dataset catalogs and what doesn’t, what is parametric and what isn’t. From what I can…
    • over 12 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • Catalog Item Property Definitions

    Joshua Chung
    Joshua Chung
    I've run into an interesting problem (glitch?) with custom catalog items. I created a few custom Catalog Items. Was having fine success placing them with the Place User Defined tool, etc. I discovered that I needed to modify the definitions assigned to…
    • over 13 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • BA DataSet Object Creation and the DataSet Files

    Tom MacKnight
    Tom MacKnight
    Here at Fluor Corporation we have used Triforma and BA in the past. However there was a hiatus of several years in our use of the product. We are just now beginning to use it again. It has matured rather well. However, like many folks we ran into difficulty…
    • Custom BIM Object Creation.pdf
    • View
    • Hide
    • over 13 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum