• Incorrect representation of Flexible duct in Single-Line promoted view.

    Shivam Soni
    Shivam Soni
    Product(s): OpenBuildings Designer Version(s): CONNECT Edition Area: Mechanical Design Subarea: Duct Problem description Observing disconnection of Diffusor from Flexible Duct while promoting Seed. Solution…
    • over 1 year ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • How to connect two vertically placed ducts

    Souvik Mullick
    Souvik Mullick
    Product(s): AECOsim Building Designer Version(s): 08.11.09.866, 10.03.00.40 Area: HVAC Design Subarea: Ducts Problem Description Proper connection is not occurring while joining two vertically placed…
    • over 5 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • Duct Sizing - Excessive Ductwork pressure due to Universal tees

    Shane Regan
    Shane Regan
    Product(s): Hevacomp Version(s): V8i Environment: N/A Area: Netsys Subarea: Ductwork Problem Excessive pressure drops found upon sizing ductwork system. Solution Hevacomp will often automatically…
    • over 5 years ago
    • Hevacomp
    • Hevacomp Wiki
  • Placing Flex Duct Around An Obstruction

    Robert DiMauro
    Robert DiMauro
    Product(s): AECOsim Building Designer Version(s): 08.11.09.829 Environment: N\A Area: HVAC Design Subarea: Ducts Problem Description How can I place a flex duct around an obstruction…
    • over 7 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • Elements are not visible

    CarstenGauger
    CarstenGauger
    Product(s): AECOsim Building Designer Version(s): 08.11.09.831 Environment: N\A Area: HVAC Design Subarea: Ducts Problem Description After the installation of AECOsim Building Designer the…
    • over 7 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • Duct sizing - Roughness figures

    Shane Regan
    Shane Regan
    Product(s): Hevacomp Mechanical Designer Version(s): V8i Environment: N/A Area: Netsys Ductwork Subarea: N/A Overview Roughness values used in Netsys Duct sizing calculations are dependant…
    • over 7 years ago
    • Hevacomp
    • Hevacomp Wiki
  • RE: "please change the working units to imperial units"

    Christopher Holt
    Christopher Holt
    We seem to have the triforma config, but it does look like it is metric as per the image... We get the warning at start-up and when we try to use the mechanical elements. We don't get any warning for placing smart lines etc.
    • over 9 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • Turning off Centerlines in Round Ducts

    Alifur Mandal
    Alifur Mandal
    Product(s): OpenBuildings Designer Version(s): Connect Edition Area: HVAC Design Problem Description Can centerline display in the 3D model be turned off in a round duct? Steps to Resolve All round ducts automatically…
    • 5 months ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki