• FAQ-CS-ExtPT

    MarcosBeier
    MarcosBeier
    RM Bridge FAQ Concrete Structures External Tendons
    • CS-E_PT.jpg
    • View
    • Hide
    • 6 months ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Files
  • Recalc Window 2. Extended Settings: 2. Pre-stressing

    MarcosBeier
    MarcosBeier
    The Recalc Window 2. Extended Settings: 2. Pre-stressing allows the users to set additional definitions for the calculations related to the stressing of tendons: Update CS Values: (-) duct areas : The area of the ducts is excluded in a new cross-section…
    • 8 months ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
  • 25. Concrete Structures - External Prestressing

    MarcosBeier
    MarcosBeier
    In this Demo example a simple-supported beam with three different prestressing is considered for comparison: Variant 1 - PExt: External Tendons Only Variant 2 - DEFAULT: External and Internal Tendon Variant 3 - PInt: Internal Tendons Only …
    • 6 months ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
  • For Deliverables Management: Removed external organization

    Elizabeth Torres
    Elizabeth Torres
    For Deliverables Management: If an external organization is removed, do they still have access to anything they sent and received? Is there a way to grant an external org read only access?
    • over 1 year ago
    • ProjectWise
    • ProjectWise Deliverables Management Forum
  • Q. Does AutoPIPE V8i rely on any external software like ActiveX, Java, Adobe Flash, dynamic link libraries etc?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Area: Installation Original Author: Bentley Technical Support Group Problem: Does AutoPIPE V8i rely on any external software like…
    • 7 days ago
    • AutoPIPE
    • AutoPIPE Wiki
  • Entering catchment data directly to a catch basin

    Jesse Dringoli
    Jesse Dringoli
    Product(s): StormCAD, CivilStorm, SewerGEMS Version(s): CONNECT Edition, V8i Area: Modeling Problem Is it possible to enter catchment data like the C value, area, and time of concentration directly to a catch basin, rather…
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Understanding Catchbasin Known/Additional/External flows

    Larry Abla
    Larry Abla
    Product(s): SewerGEMS, CivilStorm, StormCAD Version(s): 08.11.XX.XX and 10.00.XX.XX Area: Modeling Problem Using the GVF-Rational (StormCAD) solver, what are the different types of inflows that a user can apply at a catch basin…
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Level Manager column shows Level as External

    Andrew Bell
    Andrew Bell
    Product: MicroStation Version: 08.11.09.459 Environment: N\A Area: Levels Subarea: Level Manager Problem Description When turning on the "Library" column in level manager “**External**” will…
    • over 6 years ago
    • MicroStation
    • MicroStation Wiki
  • 05. Is External Pressure used for Hoop Stress Calculation in AutoPIPE?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i, CONNECT; Environment: N/A Area: Calculation Subarea: Original Author: Bentley Technical Support Group …
    • over 7 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 04. How to modify the external pressure ring stiffener type and size?

    JamieP
    JamieP
    Answer: Observe that the following model has been created in AutoPIPE Vessel for a simple horizontal pressure vessel with ring stiffener (with Angle) for external pressure reinforcement: To modify the stiffener, go to Execute>Convert Results as…
    • over 3 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • Trimble Business Center connection

    J03 C:\
    J03 C:\
    Trimble Experts- I am attempting to add an External Service to Trimble business center. It says that you can connect ProjectWise but gives no instruction. The values it is looking for are below. I have entered in my web server address, my user as well…
    • Answered
    • over 8 years ago
    • ProjectWise
    • ProjectWise Design Integration Forum
  • Internal Surfaces appearing in PartL U-Value checks

    Shane Regan
    Shane Regan
    Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview The SBEM calculation engine performs a comprehensive check on U-Values for external…
    • over 3 years ago
    • Hevacomp
    • Hevacomp Wiki