• Could not open the default project. need help urgently

    vishal jadhav
    vishal jadhav
    • Answered
    • over 2 years ago
    • Hevacomp
    • Hevacomp Forum
  • First floor ceiling and roof

    Aakil Patel
    Aakil Patel
    My model consists of two floors, 2.7m high for first floor and 2.7m for second floor. I added a pitch roof which messed the whole model up, so i deleted the roof data from the DDBROOF.NDX folder along with the ROOFPOLY.* and RLIGHTPOLY.* files. The model…
    • over 2 years ago
    • Hevacomp
    • Hevacomp Forum
  • Guide to Electrical Design Hevacomp

    Mausam Magar
    Mausam Magar
    Is there a guide for the electrical design software? I am new to Hevacomp and have only used amtech before. Also I have noticed that the application window says 17th edition but there is an option for the 18th edition too?
    • over 2 years ago
    • Hevacomp
    • Hevacomp Forum
  • Hevacomp compatibility with Projectwise Explorer

    blutejpj
    blutejpj
    Is Hevacomp integrated with projectwise? Is their a routemap to using Hevacomp with projectwise at all?
    • over 2 years ago
    • Hevacomp
    • Hevacomp Forum
  • Repair project file

    ALAN HEATON
    ALAN HEATON
    Hi Shane i wonder if you would kindly take a look at a project file which may be in need of repair. This has happened before and I uploaded the project folder and you where able to repair the file path to the project. The project was loading fine…
    • over 3 years ago
    • Hevacomp
    • Hevacomp Forum
  • Derate XLPE cables to run to a maximum of 70 deg instead of 90 deg

    Martin Griffin
    Martin Griffin
    Hi, Please can anyone tell me the best way to derate XLPE cables to run to a maximum of 70 degrees instead of 90? Thanks
    • over 6 years ago
    • Hevacomp
    • Hevacomp Forum
  • Hevacomp Connect - Supply type Fault Level input

    Richard Foster
    Richard Foster
    Hi, regarding Connect, under Supply type Special what value is expected for Fault Current? Is it phase to neutral for single phase and three phase supplies or for a three phase supply do we input the fault current between phases?
    • over 7 years ago
    • Hevacomp
    • Hevacomp Forum
  • Hevacomp Heat Losses - Negative Heat Losses

    Brian Elliot
    Brian Elliot
    Can anyone tell me if there is a quick way to eliminate negative heat losses from a calculation run without having to go through and manually exclude those rooms? I would rather that these spaces display as zero heat loss rather than a nett heat gain…
    • Answered
    • over 7 years ago
    • Hevacomp
    • Hevacomp Forum
  • How is volume flow rate calculated in Netsys?

    Thomas Nutt
    Thomas Nutt
    We have a modelled system in Hevacomp which has a cooling load of 16,065 kW and a delta T of 8.4 deg C. Hevacomp calculates the volume flow rate to be 421 l/s. How does Hevacomp calculate this and what value does it use for the specific heat capacity…
    • Answered
    • over 7 years ago
    • Hevacomp
    • Hevacomp Forum
  • Hevacomp - Netsys pipe properties

    Rory Jones
    Rory Jones
    Hi On Hevacomp Netsys I am trying to get pipe properties out. With flow rates some values are coming out as 0.000 and it seems like the minimum value it will show up is 0.010? Is there a way to change this so that it doesn't round up/ not show values…
    • Answered
    • over 8 years ago
    • Hevacomp
    • Hevacomp Forum
  • Frequency Simulation - Fresh Air Ventilation / Multi Zone Air Flow Model

    Kevin Hayward
    Kevin Hayward
    Hi All, I am carrying out a frequency simulation calculation and want to add in an amount of fresh air to see the effect this has on overheating - either via air change rate or fresh air for occupants. I know that the methodology for this is either…
    • over 8 years ago
    • Hevacomp
    • Hevacomp Forum
  • RE: Runtime error 53

    Duncan Brown
    Duncan Brown
    Stuart I have put together a new Wiki document that should prove the quickest way of getting your existing custom cable data into the new installation.
    • over 8 years ago
    • Hevacomp
    • Hevacomp Forum
  • Connect - Max Zs

    StuartO
    StuartO
    Table 41.3 of BS 7671 stipulates the maximum Zs for circuits. Having printed off the impedance results for a project a number of circuits are in excess of the maximum permitted zs from table 41.3 How does Connect carry out a calculation, and then…
    • over 9 years ago
    • Hevacomp
    • Hevacomp Forum
  • Connect Operation Manual

    StuartO
    StuartO
    Where can I access the operation manual for connect?
    • over 9 years ago
    • Hevacomp
    • Hevacomp Forum