• How To Create A Custom Cable Type

    Lindon Phillips
    Lindon Phillips
    I can't Find anything explaining how to create a custom cable type. From the " How to move customised Cable Files to a new version " I under stand the first window but the bottom half of this second window I don't really under stand what the initial…
    • over 1 year ago
    • Hevacomp
    • Hevacomp Forum
  • Could not open the default project. need help urgently

    vishal jadhav
    vishal jadhav
    • Answered
    • over 2 years ago
    • Hevacomp
    • Hevacomp Forum
  • CIBSE Weather Data

    Aakil Patel
    Aakil Patel
    Hi, I have downloaded CIBSE weather data, however when following the steps of installing the weather files from CIBSE and saving then within the Weather data>Cibse folder located at C:\ProgramData\Bentley\Hevacomp V8i\Hevacomp. I cant see no weather…
    • Answered
    • over 2 years ago
    • Hevacomp
    • Hevacomp Forum
  • Setting up a room under a roof

    Sebastian Mlynarski
    Sebastian Mlynarski
    Hi, Bit of a tricky situation. I have been trying to model a small server room in an existing loft space. (quick revit model attached to show the plan with roof removed). I am having some issues when setting up the roof level. I have modelled the…
    • Answered
    • over 2 years ago
    • Hevacomp
    • Hevacomp Forum
  • CIBSE Gain Queries

    Graeme Matheson
    Graeme Matheson
    I have turned off infiltration, ventilation, occupants and casual gains from my model to test the solar load portion only. However I still see loads attributed with "Convective" and "Latent" (albeit small). Should these loads exist in my calculation…
    • Answered
    • over 3 years ago
    • Hevacomp
    • Hevacomp Forum
  • HELP WITH LOAD CALCULATIONS DATA AND TRANSFERRING IT INTO TOTAL BUILDING DESIGN

    seamus murphy
    seamus murphy
    I have constructed my hevacomp model in the design database using the load calculation tab along with sizing all my mechanical pipe and duct systems using the pipe and duct sizer netsys tab. I am wondering if it is possible to transfer all this data…
    • over 4 years ago
    • Hevacomp
    • Hevacomp Forum
  • Floor Locations

    Dean Beale
    Dean Beale
    Good Afternoon All, Using Hevacomp design database (and CAD input) I have built a large 4 storey 'complex' building from the 1700's containing around 200 rooms, to get some idea of heat losses throughout the building. However, now the model has been…
    • Answered
    • over 7 years ago
    • Hevacomp
    • Hevacomp Forum
  • Silent installation of Hevacomp v8i 26.0

    Nick Shard
    Nick Shard
    Hello, Can anyone assist with the silent installation of Hevacomp v81 26.0. I have found forum posts for Microstation, but not Hevacomp: http://communities.bentley.com/products/microstation/w/microstation__wiki/4170 I need to create a silent…
    • over 7 years ago
    • Hevacomp
    • Hevacomp Forum
  • Netsys Heating Connecting Pipe Header Problems

    Graham Downes
    Graham Downes
    When trying to add a pipe header into a Netsys project, firstly I can't seem to edit the length/size only the rotation and secondly once the header has been positioned and supposedly connected to the emitters and a system marker, it comes up with an error…
    • Answered
    • over 7 years ago
    • Hevacomp
    • Hevacomp Forum
  • Why is Hevacomp not producing a .xml file for EPC?

    Jasmin D
    Jasmin D
    So I am using Bentley Hevacomp to create EPC's and then lodge them on the CIBSE lodgement portal. However, the Hevacomp on my PC is not producing a .xml file so I am having to jump onto my colleague's PC and get the .xml from there. Obviously this is…
    • over 7 years ago
    • Hevacomp
    • Hevacomp Forum
  • Why is the Hevacomp BRUKL Document not showing Solar Thermal Systems?

    Jasmin D
    Jasmin D
    Hi, Please would someone be able to help me. I have been trying to complete an SBEM for a client and this one part of the BRUKL document won't show up when I run the compliance section of the Part L in Hevacomp. On the roof of the building in question…
    • Answered
    • over 7 years ago
    • Hevacomp
    • Hevacomp Forum
  • Inserting new floors, FFL incorrect within project!

    James Green
    James Green
    I am currently building a multiple storey warehouse style building with offices internal. The main space is mostly ground floor, with 1No First Floor office to one side, 1No Storage space to the other side and then 1st/2nd/3rd floors in offices in the…
    • over 7 years ago
    • Hevacomp
    • Hevacomp Forum