• Assigning Windcatchers through Flowpath Data

    Krishnendu Paul
    Krishnendu Paul
    Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview The article provides detailed guidance of how to model windcatchers and assign…
    • over 1 year ago
    • Hevacomp
    • Hevacomp Wiki
  • Could not open the default project. need help urgently

    vishal jadhav
    vishal jadhav
    • Answered
    • over 2 years ago
    • Hevacomp
    • Hevacomp Forum
  • Does anyone have experience of modelling an air supported structure to ascertain the heat loss.

    Colin Swan
    Colin Swan
    We have a project where our client is looking to provide a new air supported structure/ dome over an existing training pitch, the structure is to be heated and cooled as required. Can this be modelled using Hevacomp.
    • over 3 years ago
    • Hevacomp
    • Hevacomp Forum
  • Energy Calculation - HWS and occupancy

    Shane Regan
    Shane Regan
    Product(s): Hevacomp Version(s): V8i Environment: N/A Area: Mechanical Designer Subarea: Design Database Problem Hot Water Usage is reported as zero upon running the Design Database Energy…
    • over 5 years ago
    • Hevacomp
    • Hevacomp Wiki
  • RE: Modelling a zone (room) within a zone (room)

    Shane Regan
    Shane Regan
    Hi Stuart, Modelling of such spaces can only be directly achieved in Hevacomp Simulator by using Atrium key words. However if you wish to use Design Database for level 3/4 Part L calcs then there are three workaround options available - please see further…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Forum
  • RE: Plant Schedule

    Stephen Brown
    Stephen Brown
    Hello Matt, Can you clarify which software you wish to do this in? Are you talking about Design Database - PartL or Dynamic Simulation? Regards Steve
    • over 6 years ago
    • Hevacomp
    • Hevacomp Forum
  • RE: Yearly Gas Useage

    Shane Regan
    Shane Regan
    While these results are not directly available in the software, the Energy calculation in Design Database may be helpful as it will provide the annual energy usage in GJ. You could then use these figures to work out your gas consumption.
    • over 6 years ago
    • Hevacomp
    • Hevacomp Forum
  • Omitted Recommendations shown in Recommendations Report

    Shane Regan
    Shane Regan
    Product(s): Hevacomp Version(s): V26 Environment: N/A Area: Design Database Subarea: Part L Problem 'Omit Recommendation' selections are not reflected in the Recommendations Report. Solution…
    • over 3 years ago
    • Hevacomp
    • Hevacomp Wiki
  • CIBSE Gain calculation - Importance of accurate input data

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Version(s): V8i Environment: N/A Area: Design Database Subarea: Results Overview Unusual results are likely to occur if Building model data is inadequate. Method Comprehensive…
    • over 4 years ago
    • Hevacomp
    • Hevacomp Wiki
  • RE: wall heights

    Shane Regan
    Shane Regan
    Hi, Please use the 'Setup intermediate floors/ceilings' function (located in CAD Input > Roof/floors ) to set up the adjacencies between these floors. This will remove all gaps between your floors.
    • over 6 years ago
    • Hevacomp
    • Hevacomp Forum
  • RE: Glazing database - effect of adding blind on G value and Shading co-efficient - CIBSE Gain

    Shane Regan
    Shane Regan
    Hi Michael, It is my understanding that the Uvalue and light Transmittance figures will not be affected by the blind, while the Shading Coefficient and SHGC would definitely be impacted. However the glazing manufacturer will need to confirm this for…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Forum
  • CIBSE Gain Calculation - Load types

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Design Database Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview The following is a breakdown of components that make up the gains in the CIBSE Heat…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Wiki
  • RE: CIBSE Gain - Results Breakdown

    Stephen Brown
    Stephen Brown
    Matthew, you have probably turned on Temperature Rise in the Design Data tab. When you use Temperature Rise the individual loads are combined in the underlying equations and cannot be accurately split out afterwards.
    • over 7 years ago
    • Hevacomp
    • Hevacomp Forum
  • CAD Model Design - Gap Between Roof And Walls

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview When modelling a roof in Hevacomp a space can sometimes appear between the roof…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Wiki
  • RE: Uncontrolled heat gains

    Stephen Brown
    Stephen Brown
    Hello, Please post your second question regarding CIBSE Heat Gain to a separate thread and I will try to answer it there. With regard your question on Summer - The Summer calc uses Operative Temp as defined in CIBSE Guide A5 Section 1.2.2. This equates…
    • over 7 years ago
    • Hevacomp
    • Hevacomp Forum
  • Why is the Hevacomp BRUKL Document not showing Solar Thermal Systems?

    Jasmin D
    Jasmin D
    Hi, Please would someone be able to help me. I have been trying to complete an SBEM for a client and this one part of the BRUKL document won't show up when I run the compliance section of the Part L in Hevacomp. On the roof of the building in question…
    • Answered
    • over 7 years ago
    • Hevacomp
    • Hevacomp Forum
  • RE: Hevacomp Zone definition

    Shane Regan
    Shane Regan
    Hi, The best way to zone your building largely depends on what results you require. The following excerpt from the manual may help to clarify: Rooms can be placed in particular zones and floors so that zone and floor sub-totals can be selected and…
    • over 7 years ago
    • Hevacomp
    • Hevacomp Forum
  • RE: Level 5 DSM SBEM & EPC; .

    Shane Regan
    Shane Regan
    Hi Shaun, to simulate the atrium space you would need to draw the rooms as usual, but name them according to your Atrium Keyword (in Simulator > Design Data > Atrium Spaces). For Example if your keyword was ATRIUM, then the rooms should be named ATRIUM…
    • over 7 years ago
    • Hevacomp
    • Hevacomp Forum
  • RE: Hevacomp - Design Database - Special Surface Types

    Stephen Brown
    Stephen Brown
    Hi Rob, By any chance is this a glazed door? Any door that is more than 50% glazed is considered a Window for PartL purposes. If you set a glazed area greater than 50% then we automatically treat this as a window when we pass it to SBEM. This is…
    • over 7 years ago
    • Hevacomp
    • Hevacomp Forum
  • RE: Floor Level Correction -

    Stephen Brown
    Stephen Brown
    The workflow for correcting a finished floor level can be found in our Support Solutions here: http://communities.bentley.com/products/building/performance/w/building_performance__wiki/11959.changing-floor-heights
    • over 8 years ago
    • Hevacomp
    • Hevacomp Forum
  • DXF Import Issues - Drawing is too large error

    Shane Regan
    Shane Regan
    Product(s): Hevacomp Mechanical Design Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview This document details what to do should you encounter the following "Drawing is…
    • over 5 years ago
    • Hevacomp
    • Hevacomp Wiki
  • Editing project data - Default Data vs Global Change

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview This document provides guidance on the difference between CAD Input Default Data…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Wiki
  • CIBSE Gain calculation - Solar gains at night

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview CIBSE Gain results can often display Solar Gains at night, for example: Explanation…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Wiki
  • Design Database hangs after opening project, or "Timeout accessing the database" error occurs

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Mechanical Design Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview Design Database projects may stop functioning or generate a Timeout error on opening…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Wiki
  • RE: Save custom fabric data for all projects?

    Shane Regan
    Shane Regan
    Hi, the following document from our Wiki page explains how to do this: communities.bentley.com/.../creating-a-template-project.aspx Please let us know if you have any further questions.
    • over 9 years ago
    • Hevacomp
    • Hevacomp Forum