• Heating System Controls greyed out

    Shane Regan
    Shane Regan
    Product(s): Hevacomp Version(s): V8i Environment: N/A Area: Design Database Subarea: Part L Problem Heating System Controls are greyed out on the Part L HVAC Systems tab. Solution These…
    • over 3 years ago
    • Hevacomp
    • Hevacomp Wiki
  • Hevacomp Energy Assessor Level 5 Course - London, September 2018

    Shane Regan
    Shane Regan
    Hevacomp Energy Assessor (Non-dwelling) Level 5 (Dynamic Simulation) Allows Hevacomp users - via an accredited Energy Assessor scheme provider - to work towards Energy Assessor status to show competency in production of EPC's using Hevacomp Simulator…
    • over 5 years ago
    • Hevacomp
    • Hevacomp Blog
  • Hevacomp Energy Assessor course and exam - London, May 2018

    Shane Regan
    Shane Regan
    Hevacomp Energy Assessor (Non-dwelling) Level 3 & 4 (SBEM) Allows Hevacomp users - via an accredited Energy Assessor scheme provider - to work towards Energy Assessor status to show competency in production of EPC's using an approved SBEM interface…
    • over 5 years ago
    • Hevacomp
    • Hevacomp Blog
  • Hevacomp Part L Energy Assessor course and exam - September 2017

    Shane Regan
    Shane Regan
    Hevacomp Energy Assessor (Non-dwelling) Level 3 & 4 (SBEM) Allows Hevacomp users - via an accredited Energy Assessor scheme provider - to work towards Energy Assessor status to show competency in production of EPC's using an approved SBEM interface…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Blog
  • EPC and Recommendations menus

    Shane Regan
    Shane Regan
    Product(s): Hevacomp Version(s): V8i Environment: N/A Area: Design Database Subarea: Part L Problem Part L EPC and Recommendations tabs are greyed out, as below. Solution This occurs…
    • over 3 years ago
    • Hevacomp
    • Hevacomp Wiki
  • RE: Modelling a zone (room) within a zone (room)

    Shane Regan
    Shane Regan
    Hi Stuart, Modelling of such spaces can only be directly achieved in Hevacomp Simulator by using Atrium key words. However if you wish to use Design Database for level 3/4 Part L calcs then there are three workaround options available - please see further…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Forum
  • RE: HVAC Systems - Zones

    Shane Regan
    Shane Regan
    Hi Matt, I would firstly advise caution if you are intending to use Part L to determine if natural ventilation is required, as SBEM is not a design tool indicative of real-world conditions. (To see if natural ventilation is required you would need to…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Forum
  • Omitted Recommendations shown in Recommendations Report

    Shane Regan
    Shane Regan
    Product(s): Hevacomp Version(s): V26 Environment: N/A Area: Design Database Subarea: Part L Problem 'Omit Recommendation' selections are not reflected in the Recommendations Report. Solution…
    • over 3 years ago
    • Hevacomp
    • Hevacomp Wiki
  • Bentley Hevacomp V8i SS1 Update 5 now available for download

    Shane Regan
    Shane Regan
    Hevacomp Update 5 can be downloaded as detailed here. This incremental update addresses changes to the UK Part L SBEM and BRUKL engines for lodging EPC’s. Design Database interface to SBEM V5.3a is accredited for producing English, Welsh and Scottish…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Blog
  • Hevacomp Part L, SBEM update 5.3.a and 4.1.g

    Shane Regan
    Shane Regan
    Changes to the SBEM calculation were recently introduced, mainly to incorporate new constructions from the updated NCM modelling guides. Thus, Energy Performance certificates and Compliance documents must now be generated with: SBEM 5.3.a - for Part…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Blog
  • Hevacomp Part L Energy Assessor courses: Now open for registration

    Shane Regan
    Shane Regan
    Hevacomp Energy Assessor (Non-dwelling) Level 3 & 4 (SBEM) Allows Hevacomp users - via an accredited Energy Assessor scheme provider - to work towards Energy Assessor status to show competency in production of EPC's using an approved SBEM interface…
    • over 7 years ago
    • Hevacomp
    • Hevacomp Blog
  • Why is Hevacomp not producing a .xml file for EPC?

    Jasmin D
    Jasmin D
    So I am using Bentley Hevacomp to create EPC's and then lodge them on the CIBSE lodgement portal. However, the Hevacomp on my PC is not producing a .xml file so I am having to jump onto my colleague's PC and get the .xml from there. Obviously this is…
    • over 7 years ago
    • Hevacomp
    • Hevacomp Forum
  • Here’s what you need to know about SAP in Hevacomp

    Shane Regan
    Shane Regan
    As you may have noticed, the SAP calculation is no longer available in the latest version of Hevacomp. While SAP 2005 was available in Hevacomp v25, this is not available in Hevacomp v26 as the standards are no longer applicable. It was not possible…
    • over 7 years ago
    • Hevacomp
    • Hevacomp Blog
  • Scottish Section 6 2015 regulations update

    Shane Regan
    Shane Regan
    <Update> We are pleased to announce that SBEM v5.2.g has been fully accredited for use in Hevacomp Update 4, available for download as detailed here . <Update> The Scottish building regulations are due to be updated from Section 6 2010 to 2015…
    • over 8 years ago
    • Hevacomp
    • Hevacomp Blog