• Hevacomp Transition to OpenBuildings

    Shane Regan
    Shane Regan
    With the Hevacomp brand being synonymous with building design for decades, we are excited to announce the transition of its capabilities to OpenBuildings Designer. Integrating the building services calculations from Hevacomp into the multidiscipline…
    • FAQ_Hevacomp_to_OpenBuildings_Designer_LTR_EN_LR.pdf
    • View
    • Hide
    • over 3 years ago
    • Hevacomp
    • Hevacomp Blog
  • Run Time Error 11 - Pipework sizing

    Philip Webster
    Philip Webster
    I have a run time error 11 appearing when sizing heating pipework in netsys. I had previously sized the system with no issue, however made some amendments and when re-running it the error has appeared. Could anyone assist as I currently can't access…
    • over 3 years ago
    • Hevacomp
    • Hevacomp Forum
  • Error when running 'size duct' in Netsys

    Sebastian Mlynarski
    Sebastian Mlynarski
    Hi, I am getting an error when I try to size the system in Netsys Ductsizer. After drawing the system I am met with 'Duct with system marker is not the start duct for the system'. (See attached) I have tried putting the system marker in various…
    • over 3 years ago
    • Hevacomp
    • Hevacomp Forum
  • Error 380: Invalid Property Value when clicking on Profiles in Design Database.

    Colin Barr
    Colin Barr
    Tried the other fix in this forum downloading the MatIndex.zip file and extracting in to the C drive and still have the issue. Fabric details are appearing OK also.
    • over 3 years ago
    • Hevacomp
    • Hevacomp Forum
  • Working remotely with Hevacomp

    Shane Regan
    Shane Regan
    In these challenging times when COVID-19 is imposing significant disruptions to day-to-day activities and affecting normal business flow, we at Bentley are committed to helping you transition from an office environment to working remotely or at home.…
    • over 3 years ago
    • Hevacomp
    • Hevacomp Forum
  • Working From Home with Hevacomp

    Steve Cocchi
    Steve Cocchi
    Product(s): Hevacomp Version(s): V8i Environment: Any Area: Working From Home Subarea: N/A Overview This article offers guidance on working remotely with Bentley Hevacomp. Note : The on…
    • over 3 years ago
    • Hevacomp
    • Hevacomp Wiki
  • Repair project file

    ALAN HEATON
    ALAN HEATON
    Hi Shane i wonder if you would kindly take a look at a project file which may be in need of repair. This has happened before and I uploaded the project folder and you where able to repair the file path to the project. The project was loading fine…
    • over 3 years ago
    • Hevacomp
    • Hevacomp Forum
  • Does anyone have experience of modelling an air supported structure to ascertain the heat loss.

    Colin Swan
    Colin Swan
    We have a project where our client is looking to provide a new air supported structure/ dome over an existing training pitch, the structure is to be heated and cooled as required. Can this be modelled using Hevacomp.
    • over 3 years ago
    • Hevacomp
    • Hevacomp Forum
  • Fresh Air Having Large Effect on CIBSE Gain Results

    Simon Radcliffe
    Simon Radcliffe
    Hi, I am carrying out cooling calculations for an open plan office with FCU's. When using CIBSE Gain to calculate the room cooling loads I am selecting 'conditioned primary fresh air' as I have air at 18deg C from a central AHU with no humidification…
    • over 3 years ago
    • Hevacomp
    • Hevacomp Forum
  • HEVACOMP Heat Loss Result

    Rey Andrew Gatmaitan
    Rey Andrew Gatmaitan
    Hi Good morning, For the HEVACOMP Heat Loss Calculation, is there a way to know the required supply air flow based on the calculated total heat loss from the result? I'm looking at something similar with the CIBSE gain calculation where the result…
    • over 3 years ago
    • Hevacomp
    • Hevacomp Forum
  • CIBSE Gain Queries

    Graeme Matheson
    Graeme Matheson
    I have turned off infiltration, ventilation, occupants and casual gains from my model to test the solar load portion only. However I still see loads attributed with "Convective" and "Latent" (albeit small). Should these loads exist in my calculation…
    • Answered
    • over 3 years ago
    • Hevacomp
    • Hevacomp Forum
  • Heat Gain Simulation reading No solar input

    David Forster
    David Forster
    Hi I'm running a heat gain simulation on a room that is essentially a greenhouse. The glass roof etc has all been set up as has the weather info. The results output of the simulation reads that the temperature within the room stays constant all…
    • over 4 years ago
    • Hevacomp
    • Hevacomp Forum
  • HELP WITH LOAD CALCULATIONS DATA AND TRANSFERRING IT INTO TOTAL BUILDING DESIGN

    seamus murphy
    seamus murphy
    I have constructed my hevacomp model in the design database using the load calculation tab along with sizing all my mechanical pipe and duct systems using the pipe and duct sizer netsys tab. I am wondering if it is possible to transfer all this data…
    • over 4 years ago
    • Hevacomp
    • Hevacomp Forum
  • K VALUE FOR DEFAULT BENDS AND TEES

    GL
    GL
    Hi Understood the below links gives K-value for some of the fitting however, it doesn't show the assumed value for different default bends and tees . Please could you be able to post the k vale for the default connection fittings. i want to verify the…
    • over 4 years ago
    • Hevacomp
    • Hevacomp Forum
  • MODELLING OF DUCT PASSING THROUGH RISER AT 45 DEGREE.

    GL
    GL
    HI I HAVE A DUCT PASSING VIA RISER FROM L1 TO L6 AT AN ANGLE OF 45 DEGREE OR SAY NOT IN A 90 DEGREE VERTICAL WAY. PLEASE COULD YOU BE SO KIND TO DEMONSTRATE HOW THIS CAN BE MODELED. MANY THANKS
    • Answered
    • over 4 years ago
    • Hevacomp
    • Hevacomp Forum
  • Duct Sizing - How to connect a diffuser to the underside of a plenum box

    Stephen Brown
    Stephen Brown
    Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: Netsys Subarea: Ductwork Overview Whilst designing a ductwork system it may be required to connect a ceiling…
    • over 4 years ago
    • Hevacomp
    • Hevacomp Wiki
  • Duct Sizing - How to draw an offset in Netsys

    Stephen Brown
    Stephen Brown
    This video shows how to draw an offset in Hevacomp Netsys
    • Netsys Duct Offset Up.mp4
    • View
    • Hide
    • over 4 years ago
    • Hevacomp
    • Hevacomp Files
  • Hevacomp temp files appearing on Desktop

    Shane Regan
    Shane Regan
    Product(s): Hevacomp Version(s): V8i Environment: N/A Area: N/A Subarea: N/A Problem On occasion, you may find many temporary files and some project data appears on your desktop upon running…
    • over 4 years ago
    • Hevacomp
    • Hevacomp Wiki
  • What is the latest version of Hevacomp?.? Is it V8i 26.06 .00.38 ?

    Peter Wong
    Peter Wong
    What is the latest version of Hevacomp?.? Is it V8i 26.06 .00.38 ?
    • over 4 years ago
    • Hevacomp
    • Hevacomp Forum
  • XML Generation for EPC

    Dale Green
    Dale Green
    I've been trying since 6PM GMT to generate an xml for EPC lodgement. Its now 12AM GMT and still nothing. The latest upgrade is installed. This needs lodging by 12PM 26/09. Anybody any pointers?
    • over 4 years ago
    • Hevacomp
    • Hevacomp Forum
  • Hevacomp Energy Assessor course and exam (PartL Level 3/4) - London Nov 2018

    Shane Regan
    Shane Regan
    Hevacomp Energy Assessor (Non-dwelling) Level 3 & 4 (SBEM) Allows Hevacomp users - via an accredited Energy Assessor scheme provider - to work towards Energy Assessor status to show competency in production of EPC's using an approved SBEM interface…
    • over 5 years ago
    • Hevacomp
    • Hevacomp Blog
  • Heating System Controls greyed out

    Shane Regan
    Shane Regan
    Product(s): Hevacomp Version(s): V8i Environment: N/A Area: Design Database Subarea: Part L Problem Heating System Controls are greyed out on the Part L HVAC Systems tab. Solution These…
    • over 3 years ago
    • Hevacomp
    • Hevacomp Wiki
  • Hevacomp Energy Assessor Level 5 Course - London, September 2018

    Shane Regan
    Shane Regan
    Hevacomp Energy Assessor (Non-dwelling) Level 5 (Dynamic Simulation) Allows Hevacomp users - via an accredited Energy Assessor scheme provider - to work towards Energy Assessor status to show competency in production of EPC's using Hevacomp Simulator…
    • over 5 years ago
    • Hevacomp
    • Hevacomp Blog
  • Energy Calculation - HWS and occupancy

    Shane Regan
    Shane Regan
    Product(s): Hevacomp Version(s): V8i Environment: N/A Area: Mechanical Designer Subarea: Design Database Problem Hot Water Usage is reported as zero upon running the Design Database Energy…
    • over 5 years ago
    • Hevacomp
    • Hevacomp Wiki
  • Bentley Hevacomp V8i Update 6 now available for download

    Shane Regan
    Shane Regan
    The AECOsim product team is pleased to announce the availability of Bentley Hevacomp V8i SS1 Update 6 (26.06.00.06). This incremental update addresses changes to the UK Part L SBEM and BRUKL engines for lodging EPC's. Design Database interface to SBEM…
    • over 5 years ago
    • Hevacomp
    • Hevacomp Blog
<>