• RE: wall heights

    Shane Regan
    Shane Regan
    Hi, Please use the 'Setup intermediate floors/ceilings' function (located in CAD Input > Roof/floors ) to set up the adjacencies between these floors. This will remove all gaps between your floors.
    • over 6 years ago
    • Hevacomp
    • Hevacomp Forum
  • RE: Window glazing properties, CIBSE Gain

    Shane Regan
    Shane Regan
    Hi Kenny, The different standards used by each Hevacomp calculation prescribe their own equations, each requiring their own particular variables. In the case of the CIBSE Gain calc the most important variables are the Solar Gain Factors. SHGC is not…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Forum
  • RE: Adding a layer type on wall build up

    Shane Regan
    Shane Regan
    Hi Kostas, You can enter the thermal properties of the material by selecting Special Solid Layer, at the bottom of the Layer Type list:
    • over 6 years ago
    • Hevacomp
    • Hevacomp Forum
  • Adding a layer type on wall build up

    Konstantinos Tachtatzis
    Konstantinos Tachtatzis
    Hi, I am a newbie on the software and I would appreciate your help. I am trying to calculate the U-Values of an existing external wall for a residential property. The insulation I need to add is kingspan kooltherm K118 however the software doesn…
    • Answered
    • over 6 years ago
    • Hevacomp
    • Hevacomp Forum
  • RE: Same Loading Units Different Flowrates

    Shane Regan
    Shane Regan
    For other users who may experience the above - this issue was due to different pipe sizing standards at each outlet. Please find further details here.
    • over 6 years ago
    • Hevacomp
    • Hevacomp Forum
  • Inconsistent Flow Rate at Outlets

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Version(s): V8i Environment: N/A Area: Netsys Subarea: HWS and CWS Problem Description Outlets in HWS or CWS systems may have differing Loading Units, despite the outlets…
    • over 5 years ago
    • Hevacomp
    • Hevacomp Wiki
  • RE: How to include Hot water cylinder in Netsys (CWS)

    Shane Regan
    Shane Regan
    Hi Jozef, The guidance here should assist with modelling this.
    • over 6 years ago
    • Hevacomp
    • Hevacomp Forum
  • How to include Hot water cylinder in Netsys (CWS)

    Jozef Switowski
    Jozef Switowski
    I'm designing the CWS. The Hot water installation requires a Cylinder. How can include a cylinder in the CWS design? I just can find the option to include a Cold water tank in the system. Thanks
    • Answered
    • over 6 years ago
    • Hevacomp
    • Hevacomp Forum
  • RE: Pipework Velocities Input

    Stephen Brown
    Stephen Brown
    Hi Jamie, The CIBSE table is using typical bands therefore it would make sense to enter the highest CIBSE value for each band in the system marker. This limits the velocity for any sizes within that band. The settings shown below would meet that criteria…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Forum
  • Limitations, assumptions and approximations of Hevacomp, particularly CIBSE Gain

    Brendan Fox
    Brendan Fox
    I am wondering if you could help point me in the right direction. I am wanting to better understand what are the limitations of Hevacomp in terms of the underlying assumptions and approximations that the software uses. I am mostly interested in the…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Forum
  • RE: Glazing database - effect of adding blind on G value and Shading co-efficient - CIBSE Gain

    Shane Regan
    Shane Regan
    Hi Michael, It is my understanding that the Uvalue and light Transmittance figures will not be affected by the blind, while the Shading Coefficient and SHGC would definitely be impacted. However the glazing manufacturer will need to confirm this for…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Forum
  • How to display Section Numbers on your Netsys system

    Shane Regan
    Shane Regan
    Product(s): Hevacomp Mechanical Designer Version(s): V8i Environment: N/A Area: Netsys Subarea: All Overview Enabling section numbers can help to provide clarity when inspecting or troubleshooting…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Wiki
  • RE: Rooflights - Design Simulation

    Stephen Brown
    Stephen Brown
    Hi Andrew, Rooflight openings are assumed to be a flat opening based on a specific percentage of the rooflight area. For pivoting rooflight openings the Opening Factor should be determined from the window/rooflight opening angle, where the minimum opening…
    • over 7 years ago
    • Hevacomp
    • Hevacomp Forum
  • Setting up software for use in two different locations

    Duncan Brown
    Duncan Brown
    Product(s): Bentley Hevacomp Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview It Is possible to set up Bentley Hevacomp software to make the transition from using it in…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Wiki
  • Locating a HOSTED activation key

    Shane Regan
    Shane Regan
    Product(s): All Hevacomp Products Version(s): V8i Environment: N\A Area: Activation Subarea: N\A Defect Number: Overview As part of the Bentley Hevacomp software installation, an…
    • over 2 years ago
    • Hevacomp
    • Hevacomp Wiki
  • How do I install Bentley Hevacomp V8i? (v25)

    Duncan Brown
    Duncan Brown
    Product(s): Mechanical and Electrical Designer Version(s): V8i (25) Environment: N/A Area: N/A Subarea: N/A Introduction The final version of Bentley Hevacomp V8i (v25) consists of three parts…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Wiki
  • How do I download and apply the final service pack (update)?

    Duncan Brown
    Duncan Brown
    Product(s): All Hevacomp Products Version(s): V8i (25) Environment: N/A Area: N/A Subarea: N/A Introduction The final service pack (update) for Bentley Hevacomp V8i (v25) is available for download…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Wiki
  • How do I install Bentley Hevacomp V8i? (v26)

    Shane Regan
    Shane Regan
    Product(s): Mechanical and Electrical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Introduction The latest version of the Bentley Hevacomp V8i (v26) installation…
    • 9 months ago
    • Hevacomp
    • Hevacomp Wiki
  • Hevacomp Part L Energy Assessor courses: Now open for registration

    Shane Regan
    Shane Regan
    Hevacomp Energy Assessor (Non-dwelling) Level 3 & 4 (SBEM) Allows Hevacomp users - via an accredited Energy Assessor scheme provider - to work towards Energy Assessor status to show competency in production of EPC's using an approved SBEM interface…
    • over 7 years ago
    • Hevacomp
    • Hevacomp Blog
  • Pipe and Duct fittings - K values

    Shane Regan
    Shane Regan
    Product(s): Hevacomp Mechanical Designer Version(s): V8i Environment: N/A Area: Netsys Subarea: N/A Overview K values for fittings are considered when pressure drop per meter is calculated…
    • over 7 years ago
    • Hevacomp
    • Hevacomp Wiki
  • Netsys annotation - displaying unusual results

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: Netsys Subarea: Results Overview Duct or Pipe property notes show unusual or unchanging results when you…
    • over 5 years ago
    • Hevacomp
    • Hevacomp Wiki
  • Prepare for your Hevacomp Software competency exam…

    Belinda Vela
    Belinda Vela
    Beginning in November we are offering the Hevacomp System Builder Mechanical for Energy Assessors courses. These courses are for Hevacomp users preparing for Energy Assessor status with one of the accredited EA scheme providers. These courses work towards…
    • over 7 years ago
    • User Learning
    • Bentley Institute Blog
  • RE: cable calcs

    Shane Regan
    Shane Regan
    Hi Ian, I would firstly advise making sure that your software is up to date so that you are availing of all cable types - in particular please ensure that you have the latest Content Pack installed. This is Content pack 3 which can be downloaded as detailed…
    • over 7 years ago
    • Hevacomp
    • Hevacomp Forum
  • RE: Heat loss calculation report showing a blank page. Running Windows 10

    Shane Regan
    Shane Regan
    Hi Luis, This usually means that Crystal Reports (i.e. the program that runs in the backround to take care of Hevacomp reports) is not working properly and needs to be reinstalled. Please find details on how to do so here.
    • over 7 years ago
    • Hevacomp
    • Hevacomp Forum
  • Duct Sizing - Fitting, terminator and connection codes

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: Netsys Subarea: Ductwork Overview A number of codes are used in Netsys Duct Sizing reports. While some…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Wiki
<>