• Overstress factors not applied to column in LEAP Concrete?

    Ned Taylor
    Ned Taylor
    Hi there, I am checking column capacity in LEAP Bridge CE V20. The default load combinations I am using are correctly applying the overstress factor (See below screenshot #1), however, the overstress factor is not being applied to the column calculations…
    • 1 month ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • Leap bridge concrete Flexure check

    Sumanth Reddy Katuru
    Sumanth Reddy Katuru
    Hi If we define bar length, is leap bridge software have capability to deduct development length based on dia of bar and calculate flexure check at that point.
    • 1 month ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • LEAP Substructure Cap Flexure Design @ Location 0

    Carolyn Perry
    Carolyn Perry
    Is there a way to adjust the POI so that the cap is not analyzing the flexure at location 0? Even when hooking bars the effective steel is still computed as 0. How do I get beyond this error?
    • Answered
    • 1 month ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • Can I analyze a Wooden Deck Steel Bridge with LEAP Steel?

    Kalumn Mackay
    Kalumn Mackay
    I would like to analyze a steel stringer bridge that has a transverse nail laminated wood deck. Am I able to import this wood into the Material Library in any way?
    • 3 months ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • How to change the stress limits for the intermediate bent cap from normal exposure (=0.19 sqrt(fc) <0.6ksi ) to severe exposure (=0.0948 sqrt (fc)<0.3ksi) in leap bridge concrete

    Girish Sejekan
    Girish Sejekan
    I need to change the stress limits for the bent cap from normal exposure (=0.19 sqrt(fc) <0.6ksi ) to severe exposure (=0.0948 sqrt (fc)<0.3ksi)
    • 3 months ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • LEAP Steel - Rating Mode - Lateral Torsional Buckling

    Anthony Grkman
    Anthony Grkman
    Hi, I am rating a multi-span steel bridge. When I run the model in "design mode" the program appears to correctly calculate the stress and capacity as per AASHTO specifications. Specifically, when checking Lateral Torsional Bucking within the negative…
    • 4 months ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • Open Bridge Designer Leap Bridge Steel - Partial Length Girders

    Tim Friederich
    Tim Friederich
    I am pretty new to using Leap Bridge Steel, and have a question regarding a project I am working on. I have attached a general framing plan, and was wondering if Leap Bridge Steel was capable of modeling it, mainly due to the partial length girders. The…
    • 4 months ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • LEAP Steel Bridge - Field Splice Analysis not running

    Rebekah Krol
    Rebekah Krol
    The bridge I am working on has 4 splice locations at each member. For some reason, after running an analysis, the first and last field splice do not appear to be updated and the program is still prompting me to run an analysis at those locations before…
    • 7 months ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • Prestress Beam Design Mu-p/r Ration Greater Than 1.00 But Beam Failed

    Joe
    Joe
    I am designing a prestressed slab-beam bridge and the design output shows Mr/Mu ratio of 1.06, but the value is shown in red with asterisk next to it indicating the design is not acceptable (see screenshot below). I have not been able to figure out why…
    • 7 months ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • RCPier P-Delta Analysis increases axial forces in the column.

    Aisulu Saliyeva
    Aisulu Saliyeva
    When running analysis with and without P-delta I noticed there is a substantial increase in the axial column force when P-delta is applied. At the node 1 the difference is about 300 kips. What could be a reason for such an increase? Any insight is appreciated…
    • 8 months ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • Beam properties

    Girish Sejekan
    Girish Sejekan
    When we try to copy the beam sections (BT-54) without changing any properties, the strands layout is disturbed and few of the rows are disappearing. Original Girder section strand arrangement Name Changed Girder Section strand arrangement Top…
    • 8 months ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • LEAP Bridge Steel version 22.00.02.19 - decimal requirement issues

    Aisulu Saliyeva
    Aisulu Saliyeva
    In Leap Bridge Steel, I have a curved bridge, so the girder lengths are not integer values. Under the Member Definition tab I'm unable to manually input flange plate lengths to a sufficient decimal in order to be able to run analysis (see below for the…
    • 9 months ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • RC-Pier LEAP Bridge: Column Seismic Shear Design

    Kara Turiano
    Kara Turiano
    Hello - I am modeling hammerhead piers in RC-Pier Version 20.00.00.58. EQ/ES/LS loads are applied at the bottom of the column with a user-defined seismic load combination. For some piers, the seismic shear output at the top of the column shows Combo …
    • 10 months ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • LEAP Steel- Notional Rating Load

    Mark Heltman
    Mark Heltman
    Hello, I am developing a load rating of a curved bridge in LEAP Steel ( V20.00.00.41). I have been able to run all of my required vehicles except for the Notional Rating Load (NRL). When I run the NRL combination alone, the program hard crashes. With…
    • Answered
    • 10 months ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • LEAP Steel Under Design Summary Report doesn't flag failing members

    Nathan Boswell
    Nathan Boswell
    Has anyone else had this issue? I can run an analysis and nothing gets flagged in the "Under Design Report", but after looking at the Strength V Limit State reports there are failing members in Shear. Also I have attached an example picture of what the…
    • 11 months ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • Calculating PNA of curved tub-girders for Eq. 6.10.7.3-1 in LEAP Bridge Steel version 22.00.02.19

    Aisulu Saliyeva
    Aisulu Saliyeva
    Hi, In the article below it mentions that the issue where "Distance from top of concrete deck to the neutral axis of the composite section at the plastic moment was incorrectly calculated." is fixed. However, I'm still running into this problem when…
    • over 1 year ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • Has Leap Bridge Concrete been updated to expand the use of Strut and Tie Modeling (STM)?

    Levi Gottsponer
    Levi Gottsponer
    My version of Leap Bridge Concrete currently allows for the use of STM in hammerhead pier caps, but we also need that option for all cap types in multi-column bents. We also need an STM option for prestressed and CIP concrete girders in Leap Bridge Concrete…
    • Answered
    • over 1 year ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • Kinked and flared continuous steel girder

    Kunj Doshi
    Kunj Doshi
    I need some advice. Situation I have a flared steel bridge. the bridge is continuous. i am using leap steel bridge. there are 6 girders. basically girder spacing at abutment 1 is 14 ft +/- and pier 2 is 13 ft +/-. (Flare portion). From Pier 2…
    • over 1 year ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • Circular Column Interaction Diagram

    Rob Whiteside
    Rob Whiteside
    Hello. I'm wondering how LEAP Version 21.01.00.22 calculates the maximum axial load displayed in the diagram. The diagram displays a maximum axial force allowed of 1802 kips. As expected the 1802 kips doesn't change regardless of the load combination…
    • over 1 year ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • pedestrian load in LEAP Concrete

    Dharmik Shah
    Dharmik Shah
    Hello. My pedestrian Load is 90 psf. My bridge width is 16ft. I am trying to apply 1440 plf load as pedestrian load and its a simply supported girder. Span length is 130 ft. Based on hand calc the moment in the center is 3042 kip ft. But the load shown…
    • Answered
    • over 1 year ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • LEAP Bridge Concrete Legal Load Rating Output

    Kevin Almada
    Kevin Almada
    I am performing a load rating of concrete box girders. The rating factors/tons is not displayed since the Inventory Design Load Rating Factor > 1. Is there an option to make the program display the factors even if the RF is greater than 1 or is that information…
    • over 1 year ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • Does RC Pier check shear friction in the pier cap (AASHTO 5.7.4)?

    Greg Jackman
    Greg Jackman
    Does RC Pier check shear friction in the pier cap (AASHTO 5.7.4)? I've looked in the output reports and didn't see reference to this spec section. I've also looked in the application help interface and couldn't find it. Note: my application version…
    • over 1 year ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • Beam section library randomly gets locked

    Hossein Mosavi
    Hossein Mosavi
    When I want to add/modify beam sections in the library, the software randomly won't let me edit it. I should mention that I have not used or assigned it to any girders. Figure below shows how it disables editing section property: This error frequently…
    • over 1 year ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • LBC Substructure Moments

    Nate Hicks
    Nate Hicks
    I am seeing different minimum moments in my pier cap when comparing the cap design output and moment diagram to the actual analysis output. The cap design and moment diagram are both reporting a maximum negative moment of -3599 k-ft, but the analysis…
    • over 1 year ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
  • Data Modification "Edit..." changes to parameters are not saved even after saving file and exiting the program

    David R.
    David R.
    Hello, This is an issue that I have seen with previous versions and still has not been resolved. When the need for different material properties and other design parameters is different from the generalized materials tab parameters, the use of the…
    • over 1 year ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Forum
>