• WATERGEMS Customer Meter Association & Pump Errors

    Joao
    Joao
    -trying to use loadbuilder to assign customer meters to the nearest junction/node not working, it runs but the properties of the customer meters afterward show the associated element is the meter itself still instead of the nearest junctions, and trying…
    • 6 days ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • What is the best method for adding new pipelines to existing models whose diameters are frozen? The intent is to minimize design errors and meet requirement of minimum residual head at all nodes

    Pankhuri Agrawal
    Pankhuri Agrawal
    We have executed distribution network models from about 20 tanks to 20 independent service areas for a client. Pipelines are laid. Now client wants to extend all the networks, by adding 10-15% of pipelines in all models. I have dxf files containing…
    • 6 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Visual depiction of allocated service connections to manhole in SewerGEMS

    Amine Salame
    Amine Salame
    Greetings, I am trying to automate the allocation of wastewater discharges from plots to manholes in SewerGEMS, and for that, I am using LoadBuilder with the options "Point load data" and "Nearest node". The plots wastewater service connections are…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • WaterGEMS LoadBuilder Parameters

    Amine Salameh
    Amine Salameh
    Greetings, I have defined the Thiessen polygons and the water meter shapefile layers in a water model, prior to inputting them to LoadBuilder. I have also added to the water meter point feature shapefile, a new field including the demands for each…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • No items available in Usage Field pulldown menu when adding demands or loading in LoadBuilder

    Scott Kampa
    Scott Kampa
    Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, CivilStorm, HAMMER Version(s): CONNECT Edition, V8i Area: Modeling Problem When using LoadBuilder, there are no available fields available when selecting the Usage Field…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Sewer Gems Loadbuilder cannot assign loads

    Md. Rownak Islam
    Md. Rownak Islam
    I am importing point load (near to point method) at SEWERGEMS through Load builder from ArcGIS. I have more approx 800 manholes in the network imported through Modelbuilder. However all the load is only assigned to one node only. Not the all nodes.…
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • loadbuilder

    eric kuda
    eric kuda
    every time i try to use loadbuilder it brings the "attempted to read or write protected memory", help please!!!!!
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Demand Allocation

    Ryan Beheshti
    Ryan Beheshti
    Hi, I have a billing meter database which compromises properties with two or three kinds of consumption (e.g., residential, commercial and irrigation for an individual property). I imported these duplicate demands by individual LoadBulider run through…
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Loadbuilder and assigning loads per population density

    bo kv
    bo kv
    Hello, I'm working with sewercad to design and I'm kind of greenish. Initially I had delineated my sewerline catchment manually based on the areas which would flow by topography to the sewerlines from a Gis software and created thiessen polygons from…
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Using LoadBuilder to assign customer meters to nearest pipe

    Osama Alawi
    Osama Alawi
    I am trying to assign demands to junctions using the LoadBuilder tool, I am using internal data through uploaded customer meter data and I have made sure that the base demand for the customer meters is filled. but after I assign the customer meters to…
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • How to manually make changes to assign Property Connection laterals after using LoadBuilder?

    Jose Ortiz
    Jose Ortiz
    So I have imported geolocated water meters (and associated flow data) as Property Connections using the ModelBuilder tool. Then I used LoadBuilder to assign those Property Connections to the nearest link. However, some of the laterals were assigned to…
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • ACCELERATE Webinar: 1 - Build or Update a Water System Hydraulic Model

    Angela Suarez
    Angela Suarez
    June 03, 2020 11:00 AM to 12:00 PM Eastern Time (US & Canada)
    Online
    All ACCELERATE virtual sessions are offered complimentary to all attendees. This five-part webinar series provides water industry professionals innovative ideas for operating distribution systems at lower cost while maintaining or improving service...
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Calendar
  • Load Builder

    Anan
    Anan
    I have demand shapefile for our monthly average consumption. I used it for my old Model it was working fine with it. When I created a new model as per GIS and tried to used same demand shapefile using same method ( Neared Node) it gives the error by…
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Water System Demand Between Two Models

    Alan Frygier
    Alan Frygier
    Hello, I have a question regarding the Node Demands. My consulting firm has recieved an old model that is slightly geospacially off and has many incorrect pipe lengths and diameters. So we created a new model from the GIS. My question: Is there…
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Modeling Water Loss

    Luís Alberto Menon de Araújo
    Luís Alberto Menon de Araújo
    Hi, We know that in many places a great portion of the "demand" is due to water loss and we also know that water leakage is directly proportional to the system's pressure. I would like to know, if you are doing and how you are doing to model water losses…
    • over 7 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • WaterGEMS for ArcMap Workshops

    Douglas Miranda
    Douglas Miranda
    Manual and dataset that cover the workshops about ModelBuilder, LoadBuilder and TRex applied in WaterGEMS for ArcMap. Recorded workshops resolution is found here: Playlist: ArcGIS Basics with WaterGEMS - ModelBuilder, LoadBuilder and Trex ModelBuilder…
    • WaterGEMS for ArcMap Workshops.zip
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Files
  • Doubt in Watergem node demand

    Ragavendra V
    Ragavendra V
    Hi Guys, I have a doubt in my water gem model. Currently, we are working in the industrial area project, So Each building has specific demand. I provided specific demand to the relative required nodes. My doubt their lot fo nodes has no demand required…
    • Answered
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • using-unit-loads-and-extreme-flow-factors-after-a-loadbuilder-run

    JATIN TALWAR, Water Engineer
    JATIN TALWAR, Water Engineer
    Hi, I was going through the page https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/15903/using-unit-loads-and-extreme-flow-factors-after-a-loadbuilder-run wherin the process to assign unit loads using…
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • LoadBuilder Error: A very high number of Usage Types were found

    Sushma Choure
    Sushma Choure
    Product(s): WaterGEMS, WaterCAD, SewerGEMS, Hammer, SewerCAD, CivilStorm Version(s): V8i, Connect Edition Area: Layout and Data Input Problem When trying to use LoadBuilder, the following error message occurs: "Calculations…
    • over 5 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Demand Units in WaterGEMS

    Amanda Snyder
    Amanda Snyder
    Does the "gpd" unit represent thousand gallons per day? For example, if my node has an actual demand of 1,200 gallons/day would the demand read 12 gpd in WaterGEMS?
    • Answered
    • over 5 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Population Input as plot areas

    Suseendar Ramadoss
    Suseendar Ramadoss
    Hi , I have a shape file of plot areas with number of people residing in each plot area , Is there any option to import these shape file into SewerGEMS and assign these plot area population to Manholes. Nearest node method in load builder module will…
    • Answered
    • over 5 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Error after running LoadBuilder: Export failed

    Scott Kampa
    Scott Kampa
    Product(s): SewerGEMS, StormCAD, SewerCAD, CivilStorm, WaterGEMS, WaterCAD, HAMMER Version(s): CONNECT Edition Area: Layout and Data Input Problem When running LoadBuilder, an error message is generated: Export failed. …
    • over 5 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • WaterGEMS: Loadbuilder - How to maintain Load Type After Demand Import

    Jonathan Machorro
    Jonathan Machorro
    Good evening: I'm using Load Builder with Arc-GIS and WaterGEMs, I've created Theissan Polygons and have a service area polygon with multiple Load Types: Commercial, Residential, etc. Is there a way to keep the information that states which Load Type…
    • Answered
    • over 5 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • LoadBuilder demand allocation for customer meters with taps and laterals

    Yashodhan Joshi
    Yashodhan Joshi
    Product(s): WaterGEMS, WaterCAD Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Modeling Problem How can I use customer meter elements with taps and laterals, but distribute demands to them with LoadBuilder using polygon area…
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Calculando vazões nos nós com camadas GIS com densidade demográfica

    Douglas Miranda
    Douglas Miranda
    Product(s): WaterCAD; WaterGEMS; SewerCAD; SewerGEMS; StormCAD; CivilStorm e HAMMER Version(s): 08.11.xx.xx - 10.00.xx.xx Area: Modeling Visão geral Este post mostra como usar shapefiles contendo polígonos com levantamentos…
    • over 5 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki (Português)
>