• 【MSCE】导出模型全部坐标为三维点集

    Junlin Wong
    Junlin Wong
    老师好,我现在打开了一个体模型如图 ,想要导出它的坐标(不进行任何转换)成三维点集格式,通过export coordinates 进行导出,导出的txt文件是空的,请问是什么原因?如何解决?
    • 6 days ago
    • Bentley 中国优先社区
    • ◆ 设计平台软件(MicroStation,PowerDraft, Navigator, i-model等)
  • Extracting instrument tags text from cell with VBA macro...help!

    Jacob Thompson
    Jacob Thompson
    This is the code I have, and I am trying to pull the text out of cells like in my image and spit it out into a .txt file. The code I have works for things outside of a cell, but I believe the fact of the text being inside of a cell is keeping it from…
    • 17 days ago
    • MicroStation Programming
    • MicroStation Programming Forum
  • Drafting a line with a bearing in Microstation V8

    Matt Millhorn
    Matt Millhorn
    In CAD after selecting the quadrant you want your line in you can simply type 89.5826 and it will automatically convert it to 89°58'26".... Obviously I still need to put N/S and E/W sandwiching my numbers in Microstation, but is there a way for me to…
    • 1 month ago
    • MicroStation
    • MicroStation Forum
  • move vertically or horizontally

    Sina Famili
    Sina Famili
    How can I move an element in Microstation Connect / OpenRoads with zero degree namely horizontally/vertically? as you know in V8i version, we use ENTER button after the Copy/Move command. Here, when I use ENTER button, a dialogue box appears.
    • Answered
    • 1 month ago
    • MicroStation
    • MicroStation Forum
  • What is the best procedure for loading a client's workspace in CONNECT?

    William Spagnoli
    William Spagnoli
    Just received configuration files and design information from a new client. It's been a while since I've had to handle this task. I'm early in the process, but I'm wondering the basic procedure for loading a new workspace. Not having any luck stumbling…
    • Answered
    • 4 months ago
    • Product Administration
    • Product Administration Forum
  • In CONNECT, how do I restore the letters for key-ins that were next to the tools in the tasks menu in V8i and previous versions ?

    William Spagnoli
    William Spagnoli
    • Answered
    • 5 months ago
    • MicroStation
    • MicroStation Forum
  • Microstation CONNECT V8 Manipulate Hotkey

    James Curra
    James Curra
    I recently updated my Microstation from V8i to CONNECT but changed my preferences so I have the hotkeys and toolbar similar to the V8i format. I used the following links to do it: How to display the V8i style Tasks dialog in MicroStation CONNECT Edition…
    • 7 months ago
    • MicroStation
    • MicroStation Forum
  • How to set Application Variables in User Config File

    Steven W
    Steven W
    v8i SS10 (08.11.09.931) Can you add the following line to user configuration file?? If so; then how would it be written in the config file?? MbeSetAppVariable "DWGSETTINGS", "dwgOpenGlobals.flags.openModelSpaceAs2D", 1&, 1& MbeSetAppVariable "DWGSETTINGS…
    • 8 months ago
    • MicroStation
    • MicroStation Forum
  • OFFICE BUILDING

    AbuUzaib
    AbuUzaib
    • PERSPECTIVE-101.jpg
    • View
    • Hide
    • 9 months ago
    • Visualization
    • Visualization Gallery
  • How to select a reference by clicking object

    Emiliano Porzio
    Emiliano Porzio
    How to select a reference (in a long list) by clicking on object in view. Without having to hover on object reading the reference file name and searcing for it in the long list of references windows. Tnx
    • Answered
    • 10 months ago
    • MicroStation
    • MicroStation Forum
  • When loading Civtools Microstation freezes. Any ideas on a fix?

    Levi Hitt
    Levi Hitt
    I am using Microstation V8i SELECTseries 10 Version 08.11.09.919 When I load Civtools the Message Center will say "Civtools loaded" But then I am unable to click on anything else, I eventually have to task manager > end task on microstation to be…
    • Answered
    • 11 months ago
    • MicroStation
    • MicroStation Forum
  • True Type Font Displays and Scales Incorrectly

    Jayson Perry
    Jayson Perry
    Product: MicroStation Version: v8i, CONNECT Environment: Windows 10 Area: Text Subarea: Fonts Problem When opening my drawings, some text is scaling larger and displaying incorrectly overall…
    • 11 months ago
    • MicroStation
    • MicroStation Wiki
  • Cell Custom Tool Placement dialog

    Cole DeBolt
    Cole DeBolt
    I'm looking for something similar to the old custom sidebar menu's. They allowed you to filter a cell selection by size(2"), fitting (flanged), view(Plan), facing(down), type(elbow) I realize there are a lot of tools already out there, i'd be willing…
    • over 1 year ago
    • MicroStation
    • MicroStation Forum
  • [V8i C#] Highlight reference file with red color

    IronMonkey
    IronMonkey
    Hi all, If I open a Microstation DGN file from ProjectWise, if a reference file has been deleted from ProjectWise it is highlighted with red color and the File Name is changed. How can do the same in C# or C++? Which API should I use? Thanks for…
    • Answered
    • over 1 year ago
    • MicroStation Programming
    • MicroStation Programming Forum
  • Versioning and Support for

    Michal Holejko
    Michal Holejko
    Hello, I am conducting a security assessment on behalf of Hitachi Energy and would be very grateful if these questions were answered for the application: MicroStation V8i (SELECTseries) Could you please provide me with the answers to the following…
    • over 1 year ago
    • MicroStation
    • MicroStation Forum
  • Update Data filed in Microstation Connect Version at once

    Sreekanth Pillai
    Sreekanth Pillai
    I am having a .dgn file which contains some data fields assigned. At present there are 4 character in the data field. Is it possible to change the data field to 6 characters at one time. I having nearly 120-130 data fields in one file and have nearly…
    • over 1 year ago
    • MicroStation
    • MicroStation Forum
  • A better way to debug MDL loader error 127

    Lubo B
    Lubo B
    Hello guys, is there a way to access some kind of Microstation log when user encounters MDL loader error "OS could not load xx.dll" (error 127) ? Or do I need to manually find out with applications like ProcessMonitor? I was wondering, maybe Microstation…
    • over 1 year ago
    • Product Administration
    • Product Administration Forum
  • Print Organizer Works With Some Drawings And Not With Others

    Joyce Xu
    Joyce Xu
    Hi! I'm running into kind of weird issue with Print Organizer - I have found a workaround, but would like to know why this may occur. So, I'll start up one of the DGNs that don't seem to work with the Print Organizer, start the Print Organizer. After…
    • over 1 year ago
    • Printing and Plotting
    • Printing and Plotting Forum
  • Is Microstation vulnerable to the Log4Shell Vulnerability?

    Evan Tinder
    Evan Tinder
    With the recent discovery of the Log4Shell Java/Apache Vulnerability, does this affect Microstation?
    • Answered
    • over 1 year ago
    • MicroStation
    • MicroStation Forum
  • "Mask Reference" tool removes reference linework outside of fence area

    Kevin Anderson
    Kevin Anderson
    I am having difficulty masking a reference on my sheet files. When I create a fence to mask my reference, the mask tool removes most of the reference linework outside of my fence (see screenshots). This is only an issue for a few of my sheets - the rest…
    • over 1 year ago
    • MicroStation
    • MicroStation Forum
  • How to Draw a Line with Slope

    Edip Ahmet TAŞKIN
    Edip Ahmet TAŞKIN
    I try to draw a sloped line with AccuDraw. I tried this tutorial but it didn't work as expected: https://envisioncad.com/accudraw-with-popup-calculator For example I input 1000, 1000, 1300 coordinates for the first point, second point will be 40 meters…
    • Answered
    • over 1 year ago
    • MicroStation
    • MicroStation Forum
  • Microstation Key-in: Attach Reference with live nesting

    Abhin Arramraju
    Abhin Arramraju
    Hello, I am new to MicroStation V8i. I am trying to use a batch process to reference one file to a set a drawings. My issue lies in the script for the key-in. This is what I have found so far: Key-in: RF= [configuration_variable:]<filename> […
    • over 2 years ago
    • MicroStation
    • MicroStation Forum
  • Active Scale is ignored when placing Cell

    Andrew Bell
    Andrew Bell
    Product(s): MicroStation Version(s): v8i, CONNECT Environment: N\A Area: Cells Subarea: General Problem When placing a cell, the Active Scale is being ignored and is always placed at the same…
    • over 2 years ago
    • MicroStation
    • MicroStation Wiki
  • GEOPAK Divide Function

    Krista Murphy
    Krista Murphy
    In GEOPAK is there a simple way to divide a complex chain into equal length segments? I have a chain that is comprised of a line segment and curve. I would like to be able to divide the chain similar to dividing a line or curve without doing so segmentally…
    • over 2 years ago
    • OpenRoads | OpenSite
    • OpenRoads | OpenSite Forum
  • By mistakenly i have rotate drawing shift + mouse middle button and lines are little crossed now

    King Khan
    King Khan
    By mistakenly i have rotate drawing using shift + mouse middle button and lines are little crossed now. Even i tried using redo ctrl+R its not making undo. Please can someone help me to bring drawing to its original position position.
    • Answered
    • over 2 years ago
    • MicroStation
    • MicroStation Forum
>