• New in MicroStation CONNECT Edition Update 17.1 – Remove Variables from a Block

    Smrutirekha Mahapatra
    Smrutirekha Mahapatra
    Working with parametric blocks is now simpler with the new Remove Parametric Variables option in Update 17.1. This option lets you remove all applied variables from a parametric block. While managing a parametric block with variables assigned to the…
    • over 1 year ago
    • MicroStation
    • MicroStation Blog
  • Power GEOPAK V8i - Can't Open Macro File

    Hart Weatherford
    Hart Weatherford
    In trying to setup both SCDOT and NCDOT workspaces in my Microstation GEOPAK, I've caused an issue that I can't seem to fix. When I start MS, this window opens with the mesasge "can't open macro file [C:\Program files (x86)\Bentley\PowerGEOPAK V8i (SELECTseries…
    • over 2 years ago
    • Product Administration
    • Product Administration Forum
  • Displaying All Configuration Variables

    Jayson Perry
    Jayson Perry
    Product: MicroStation Version: CONNECT, 2023 Environment: N\A Area: Configuration Subarea: General The Situation Would you like to know the path that MicroStation is using to locate a WorkSet…
    • 3 months ago
    • MicroStation
    • MicroStation Wiki
  • Display all configuration variables

    Marc Thomas
    Marc Thomas
    Product: MicroStation Version: All Environment: N\A Area: Configuration Subarea: General Please refer to Displaying All Configuration Variables for current YouTube content on this topic
    • over 2 years ago
    • MicroStation
    • MicroStation Wiki
  • Microstation CONNECT: Element not obeying constraints when parametric variables change

    Amelia Rupp
    Amelia Rupp
    I'm modelling a U-Bridge on Microstation CONNECT Update 11 and have many parameters within an Item Type list that can be changed via Dimensional>Variables. The majority of the parameters are equations and if statements depending on the 9 or so input variables…
    • Answered
    • over 4 years ago
    • MicroStation
    • MicroStation Forum
  • [Parametric Modelling] Table view for Variables

    Florian S.
    Florian S.
    It would be really nice to have a view option for the variables window when creating parametric cells. This way you could see more than one variable-set at a time and it would be much faster to edit the values. What I imagine: Parameter Name…
    • over 4 years ago
    • MicroStation
    • 3D Modeling
  • Understanding Configuration Assistant

    Shawn McGaffick
    Shawn McGaffick
    Starting with the MicroStation CONNECT Edition, Bentley has been releasing quarterly updates as a method of continuous improvement. The Configuration Migration Wizard was added to Update 4 of the MicroStation CONNECT Edition. It helped migrate legacy…
    • over 4 years ago
    • MicroStation
    • MicroStation Blog
  • 5 Easy Steps to Create a Hybrid WorkSet in the MicroStation CONNECT Edition

    Shawn McGaffick
    Shawn McGaffick
    Are you a Project Manager, Team Leader or Early Adopter who wants to stay on the cutting edge of Bentley technology? Do you want to use and adopt many of the new features and workflows but just cannot due to your projects being at V8i? Then we have…
    • Hybrid Project.zip
    • over 4 years ago
    • MicroStation
    • MicroStation Blog
  • Reporting for CAD Administrators: Working Units, Scales and Coordinate System Reporting

    Shawn McGaffick
    Shawn McGaffick
    In a project if you ever have encountered a design file that came from outside your company, department or group, you probably already know that no two “dgn” files are equal. In some cases they don’t print correctly, line styles don’t display correctly…
    • CADMgrReports.dgnlib
    • over 4 years ago
    • MicroStation
    • MicroStation Blog
  • User buttonmenu

    Mike Madrid
    Mike Madrid
    I have been setting up a corporate workspace for MS & ORD and really like how CONNECT will copy the various seed files either upon startup, or when necessary (such as customizing the ribbon for the dgnlib). However, I am not seeing this behavior for the…
    • Answered
    • over 5 years ago
    • Product Administration
    • Product Administration Forum
  • Migrating V8i Projects to MicroStation CONNECT WorkSets

    Shawn McGaffick
    Shawn McGaffick
    MicroStation V8i based configurations, made up of configuration files and variables, were typically referred to as a “Workspace”. A Workspace was composed of Users and Projects. The MicroStation CONNECT Edition is still made up of configuration files…
    • config mig image.png
    • View
    • Hide
    • over 5 years ago
    • MicroStation
    • MicroStation Blog
  • MS Var from PW Attribute

    Mike Madrid
    Mike Madrid
    I don't know if this belongs here or MicroStation Printing, but..... Is it at all possible to create a MicroStation variable from a PW Attribute for printing? Thanks, Mike
    • over 5 years ago
    • ProjectWise
    • ProjectWise Design Integration Forum
  • How to disable MS_V7AUTOSAVE and MS_V7AUTOSAVE_NODIALOG

    Leonard Jones
    Leonard Jones
    Applies To Product(s): MicroStation Version(s): V8, V8i, CONNECT Edition Environment: N\A Area: Configuration Subarea: Workspaces Original Author: Bentley Technical…
    • over 2 years ago
    • MicroStation
    • MicroStation Wiki
  • Create a Seed user Preference File (SPF) that does not contain file history

    Andrew Bell
    Andrew Bell
    Product: MicroStation Version: 08.11.09.459 Environment: N\A Area: Configuration Subarea: User Preferences How to Create a Seed user Preference File (*.SPF) that does not contain file history…
    • over 6 years ago
    • MicroStation
    • MicroStation Wiki
  • Variables - Parametrics - MicroStation

    Andrew Bell
    Andrew Bell
    How to create a parametric profile: Creating and Assigning Variables
    • over 6 years ago
    • MicroStation
    • MicroStation Wiki
  • Parametrics - MicroStation

    Leonard Jones
    Leonard Jones
    Constrains Dimension Driven Design Expressions General Parameter Sets Variables
    • over 5 years ago
    • MicroStation
    • MicroStation Wiki
  • MS_LEVEL_DO_NOT_SYNCHRONIZE_ATTACHMENT_LEVELS_TO_DGNLIB

    Gary Mansager
    Gary Mansager
    There are several posts relating to this: MS_LEVEL_DO_NOT_SYNCHRONIZE_ATTACHMENT_LEVELS_TO_DGNLIB but none of the documentation links work anymore. Nor is this variable documented. Makes MicroStation issues related to this variable difficult to support…
    • over 7 years ago
    • Product Administration
    • Product Administration Forum
  • DWG workmode not allowing the creation of Print Styles

    Mike Madrid
    Mike Madrid
    Is there a variable that will allow the users to create print styles in a project dgnlib when in DWG workmode? Also, is it possible to utilize a dgnlib when in DWG workmode? I have seen mixed results when attempting this. Thanks, Mike
    • over 7 years ago
    • MicroStation
    • MicroStation Forum
  • Missing MS_GEOCOORDINATE_USERLIBRARIES Variable

    Jacob Bailosky
    Jacob Bailosky
    I'm going through an exercise to create a custom coordinate system and it instructs you to set the MS_GEOCOORDINATE_USERLIBRARIES variable to the new dty file but when I go to Workspace > Configuration > with Categories (All) there is no MS_GEOCOORDINATE_USERLIBRARIES…
    • over 7 years ago
    • OpenRoads | OpenSite
    • OpenRoads | OpenSite Forum
  • Is there a better way to check if a configuration variable is blank?

    NFOtte
    NFOtte
    I was working on incorporating a new client's standards and was trying to idiot-proof our project setup files and ran into an issue that seems like it should have a one line solution, but I can't figure it out. After banging my head against a wall for…
    • over 8 years ago
    • Product Administration
    • Product Administration Forum
  • How to create a parametric profile: Creating and Assigning Variables

    Henk Ligtvoet
    Henk Ligtvoet
    Product(s): MicroStation Version(s): 10.00.00.25 Environment: N\A Area: Parametrics Subarea: Variables How to create a parametric profile: create and assign variables Background This brief…
    • over 8 years ago
    • MicroStation
    • MicroStation Wiki
  • MicroStation Configuration Variables in MicroStation CONNECT Edition & MicroStation 2023

    Jayson Perry
    Jayson Perry
    Product: MicroStation Version: CONNECT, 2023 Environment: N\A Area: Configuration Subarea: General Overview This technical document provides a description of published configuration variables…
    • 2 months ago
    • MicroStation
    • MicroStation Wiki
  • How to create a list of all CONNECT Edition Configuration Variables

    Robert Hook
    Robert Hook
    Product: MicroStation Version: 10.00.00.25 Environment: N\A Area: Configuration Subarea: General Background This article describes how to create a list of all configuration variables using…
    • over 2 years ago
    • MicroStation
    • MicroStation Wiki
  • Troubleshooting User Preferences Issues

    Zeno Lippi
    Zeno Lippi
    Product: MicroStation Version: V8, XM, V8i, CONNECT Environment: N\A Area: Configuration Subarea: User Preferences Some tips for troubleshooting User Preferences issues Background MicroStation…
    • 9 months ago
    • MicroStation
    • MicroStation Wiki
  • Default open dialog paths

    BenneyB
    BenneyB
    I am supporting a user that is interested in having various load/open dialogs in ProjectWise-integrated MicroStation V8 and V8i open to specific paths. For example, when using the open file dialog, she would like it to start in the folder from which she…
    • over 11 years ago
    • ProjectWise
    • ProjectWise Design Integration Forum
>