• Extracting instrument tags text from cell with VBA macro...help!

    Jacob Thompson
    Jacob Thompson
    This is the code I have, and I am trying to pull the text out of cells like in my image and spit it out into a .txt file. The code I have works for things outside of a cell, but I believe the fact of the text being inside of a cell is keeping it from…
    • 17 days ago
    • MicroStation Programming
    • MicroStation Programming Forum
  • How to turn on/off View Display of Levels with a Key-in

    Andrew Bell
    Andrew Bell
    Product: MicroStation Version: V8, XM, V8i, CONNECT, 2023 Environment: N\A Area: Levels Subarea: General Problem How to turn on or off the View Display of levels with a key-in? Solution …
    • 23 days ago
    • MicroStation
    • MicroStation Wiki
  • Drafting a line with a bearing in Microstation V8

    Matt Millhorn
    Matt Millhorn
    In CAD after selecting the quadrant you want your line in you can simply type 89.5826 and it will automatically convert it to 89°58'26".... Obviously I still need to put N/S and E/W sandwiching my numbers in Microstation, but is there a way for me to…
    • 1 month ago
    • MicroStation
    • MicroStation Forum
  • move vertically or horizontally

    Sina Famili
    Sina Famili
    How can I move an element in Microstation Connect / OpenRoads with zero degree namely horizontally/vertically? as you know in V8i version, we use ENTER button after the Copy/Move command. Here, when I use ENTER button, a dialogue box appears.
    • Answered
    • 1 month ago
    • MicroStation
    • MicroStation Forum
  • [MVBA, MicroStation V8i (SELECTseries 4) - Version 08.11.09.829 Windows x86] Attach Named fence -> Select View - Automation

    Jega Vigneshwaran G
    Jega Vigneshwaran G
    Hi all, I want to run a report for different named fence in the DGN. I see one option in key-in to attach (i.e. active named fence). Key-in: "fence named attach namedfencename" using this I need to get named fence and need to run plot so, I wrote…
    • Answered
    • 2 months ago
    • MicroStation Programming
    • MicroStation Programming Forum
  • Sistemi operativi supportati dalle versioni di MicroStation

    Zeno Lippi
    Zeno Lippi
    Product(s): MicroStation Version(s): N\A Environment: N\A Area: Installation Subarea: General Le informazioni relative al sistema operativo supportato da MicroStation possono essere ricavate…
    • 4 months ago
    • MicroStation
    • MicroStation Wiki (Italiano)
  • What is the best procedure for loading a client's workspace in CONNECT?

    William Spagnoli
    William Spagnoli
    Just received configuration files and design information from a new client. It's been a while since I've had to handle this task. I'm early in the process, but I'm wondering the basic procedure for loading a new workspace. Not having any luck stumbling…
    • Answered
    • 4 months ago
    • Product Administration
    • Product Administration Forum
  • In CONNECT, how do I restore the letters for key-ins that were next to the tools in the tasks menu in V8i and previous versions ?

    William Spagnoli
    William Spagnoli
    • Answered
    • 5 months ago
    • MicroStation
    • MicroStation Forum
  • Il Raster allegato non viene visualizzato in Raster Manager

    Zeno Lippi
    Zeno Lippi
    ​ Prodotto(i): MicroStation Versione(i): V8i, CONNECT Edition Ambiente N\A Area: Raster Subarea: N\A Problema Il file raster allegato non viene visualizzato nella casella di riepilogo…
    • 6 months ago
    • MicroStation
    • MicroStation Wiki (Italiano)
  • How to enable Position Mapping shortcuts in MicroStation CONNECT Edition?

    Jayson Perry
    Jayson Perry
    Product: MicroStation Version: CONNECT Environment: N\A Area: Configuration Subarea: User Preferences Problem Description How to enable Position Mapping shortcuts and make them visible in MicroStation…
    • 6 months ago
    • MicroStation
    • MicroStation Wiki
  • Come creare Celle di Annotazione?

    Zeno Lippi
    Zeno Lippi
    Product: MicroStation Version: V8 XM, V8i, CONNECT Environment: N\A Area: Celle Subarea: Celle di Annotazione Problema Come si possono creare celle di annotazione in MicroStation V8 XM Edition…
    • 6 months ago
    • MicroStation
    • MicroStation Wiki (Italiano)
  • Come abilitare il pattern di riempimento negli elementi di testo presenti nel Modello Foglio

    Zeno Lippi
    Zeno Lippi
    Prodotto(i): MicroStation Versione(i): V8i, CONNECT Edition Ambiente: N\A Area: Models Subarea: N\A Problema Come abilitare la visualizzazione “Riempita” del testo o delle quote quando il riferimento…
    • 7 months ago
    • MicroStation
    • MicroStation Wiki (Italiano)
  • Back-Up Automatico e salvataggio delle impostazioni

    Zeno Lippi
    Zeno Lippi
    Problema Devo configurare i backup automatici e salvare le impostazioni per i miei file di progettazione quando lavoro in MicroStation v8i o CONNECT Edition. Soluzione MicroStation v8i Innanzitutto, controllare le impostazioni di salvataggio impostate…
    • 7 months ago
    • MicroStation
    • MicroStation Wiki (Italiano)
  • Fehler beim Exportieren nach STEP, kann Parser-Datenbankdatei nicht finden.

    A_F
    A_F
    Produkt(e): MicroStation Version(en): V8i, CONNECT Umgebung: N\A Produktbereich: Austausch Produktunterbereich: STEP Problem Fehler beim Exportieren nach STEP. Beim Export einer beliebigen…
    • 8 months ago
    • MicroStation
    • MicroStation Wiki (Deutsch)
  • OpenBuildings Speedikon CONNECT Edition FAQ - Lizenzierung und Vertragliches

    Johannes Lerch
    Johannes Lerch
    Dieses FAQ beantwortet viele Fragen zu Lizenz- und Vertragsthemen in Bezug auf OpenBuildings Speedikon. 1. Was ist OpenBuildings Speedikon CONNECT Edition, wie unterscheidet es sich von Speedikon V8i und was sind die Vorteile? OpenBuildings…
    • 9 months ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki (Deutsch)
  • Wrong Characters for Degree Symbol

    Robert Karpic
    Robert Karpic
    Product: MicroStation Version: V8i Environment: N\A Area: Text Subarea: Fonts Problem Wrong character displaying for degree symbol In MicroStation V8i dimensions using a resource font show…
    • 11 months ago
    • MicroStation
    • MicroStation Wiki
  • Insert Symbol of "diameter" became an "asterisk" sign

    Robert Karpic
    Robert Karpic
    Applies To Product(s): MicroStation Version(s): 08.11.09.459 Environment: N\A Area: Text Subarea: Font Original Author: Judy Wong, Bentley Technical Support Group …
    • 11 months ago
    • MicroStation
    • MicroStation Wiki
  • Replace multiple texts/words with one text/word

    Robert Karpic
    Robert Karpic
    Applies To Product(s): MicroStation Version(s): V8 2004, V8 XM, V8i (SELECTseries) Environment: N\A Area: Text Subarea: Find / Replace Text Original Author: Conor King…
    • 11 months ago
    • MicroStation
    • MicroStation Wiki
  • Operating Systems supported by MicroStation versions

    Zeno Lippi
    Zeno Lippi
    Product(s): MicroStation Version(s): N\A Environment: N\A Area: Installation Subarea: General Information on which Operating System is supported for which MicroStation version can be obtained…
    • 4 months ago
    • MicroStation
    • MicroStation Wiki
  • How To Delete Multiple Links

    Andrew Bell
    Andrew Bell
    Product(s): MicroStation Version(s): V8i, CONNECT Edition Environment: N\A Area: Project Navigation Subarea: DGN Links How can I delete multiple Links from multiple Elements? Background Links…
    • over 1 year ago
    • MicroStation
    • MicroStation Wiki
  • Enable AccuSnap for Fence Create

    Jayson Perry
    Jayson Perry
    Product(s): MicroStation Version(s): v8i, CONNECT Environment: N\A Area: Drawing Aids Subarea: Snaps Problem Although AccuSnap is enabled, snapping the cursor does not work when placing a…
    • over 1 year ago
    • MicroStation
    • MicroStation Wiki
  • Wie kann man das angehängte Geografisches Koordinatensystem löschen

    A_F
    A_F
    Produkt(e): MicroStation Version(en): V8i und CONNECT Umgebung: N\A Produktbereich: Koordinatensysteme Produktunterbereich: Geografisch Problem Wie kann man das angehängte Geografisches Koordinatensystem…
    • over 1 year ago
    • MicroStation
    • MicroStation Wiki (Deutsch)
  • How to change the order of raster files

    Jayson Perry
    Jayson Perry
    Product(s): MicroStation Version(s): v8i, CONNECT Environment: N\A Area: Raster Subarea: N\A Problem A raster file covers the drawn elements in my design file. How can the raster file be put…
    • over 1 year ago
    • MicroStation
    • MicroStation Wiki
  • GeoMacao et MS 08.11.09.931 fr

    Pierre Grellet
    Pierre Grellet
    Bonjour, Nous utilisons actuellement GeoMacao sous MicroStation 08.11.09.916 fr et cela se passe bien. Je viens de constater qu'un nouvelle version de MicroStation (la 08.11.09.931 fr) est disponible. Qu'apporte-t-elle par rapport à la 916 et est-elle…
    • over 1 year ago
    • OpenRoads | OpenSite
    • OpenRoads | OpenSite | OpenRail Forum (French)
  • How to create a section view in a drawing, MicroStation V8i?

    Laurentiu Tilihoiu
    Laurentiu Tilihoiu
    Hello everyone, I am new in this community and I learning to work with MicroStation V8i. I encountered problems in drawing because I don't know how to create a side view directly from sheet drawing. Please see the attached file, for example, sections…
    • Answered
    • over 1 year ago
    • MicroStation
    • MicroStation Forum
>