There is an inconsistent error with OPIM 10070032en where the program rotates dimension text upside down when schema is edited. Sometimes modifying schema there is no issues and sometimes it will cause this error.
NOTE: The upside down dimension text…
Does anyone have hints on How To Get Topworks / Operators to be shown on Iso's.
We want Operator description and Orientation.
Can this be achieved by using 'attributes' of components, and then trigger IsoMetric Manager to populate values on ISO's…
Hello Tuan,
This is a known issue. If there is no Part ID present in OpenPlant Isometrics Manager, then it display a B0 label. This has been fixed in latest version of OpenPlant Isometrics Manager.
HTH
-Regards | Rahul Kumar
Thanks Ray,
We have logged an Enhancement # 382891 based on SR # 7000562506 you have logged. This will further gets evaluated by product management team.
HTH
-Regards | Rahul Kumar
Thanks to confirm Markus,
I should have written that. As Gaurav Mentioned, sometimes for any sub classes if you need different graphical symbol (with different ports etc), then component scripting part required if it is not available. You can request…