Applies To
Product(s):
WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack
Version(s):
CONNECT Edition, V8i
Area:
Installation
Problem
When installing a Bentley Hydraulics and Hydrology…
Product(s):
Bentley PondPack
Version(s):
08.11.
Area:
Output and Reporting
Problem
In pondpack, what does the following warning mean: " WARNING: Outflow hydrograph never crested (last ordinate= max outflow). " Problem Number…
Product(s):
Bentley WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, Hammer, WaterCAD
Version(s):
V8i, CONNECT Edition
Area:
Licensing
Problem
Do I need to uninstall and reinstall the OpenFlows product and…
Applies To
Product(s):
WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD
Version(s):
CONNECT Edition, V8i
Area:
Installation
Problem
In some cases, you may need to extract…
Product(s):
WaterGEMS, WaterCAD, HAMMER, SewerCAD, SewerGEMS, StormCAD, CivilStorm, PondPack
Version(s):
V8i, CONNECT Edition
Area:
Installation
Problem
When trying to open AutoCAD one of the following error message occurs…
Product(s):
PondPack, CivilStorm, SewerGEMS
Version(s):
V8i, CONNECT Edition
Area:
General
Problem
In the Composite Outlet Structure results, what does the message "CRIT.DEPTH CONTROL" mean for a culvert?
Solution…
Product(s):
PondPack, CivilStorm, SewerGEMS
Area:
General
Problem
One or multiple of the following problems occur when attempting to compute a model, or a composite outlet structure, when a composite outlet structure includes…
Product(s):
PondPack
Version(s):
V8i, CONNECT Edition
Area:
Modeling
Problem
When trying to compute PondMaker step 2, the following user notification appears:
"The target peak X ft³/s is greater than the inflow hydrograph…
Product(s):
Bentley PondPack
Version(s):
08.11.XX.XX
Environment:
N\A
Area:
Modeling
Subarea:
N\A
Problem
Can the Trapezoidal pond type be used to model an inclined ditch acting as a pond…
Product(s):
PondPack
Version(s):
09.XX.XX.XX, 10.XX.XX.XX
Area:
Analysis/Computation
Problem
WARNING : Charged riser flow adjusted to weir flow rate to maintain convergence. If adjustments are desired, substitute a user defined…
Product(s):
PondPack
Version(s):
V8i, CONNECT Edition
Area:
Modeling
Problem
How can the Modified Rational method be used in a case where separate predevelopment and postdevelopment information is not known? For example a…
Product(s):
PondPack
Version(s):
CONNECT Edition, V8i
Area:
Analysis/Computation
Problem
When trying to compute a model with a pond outlet structure, the following red user notification appears: "The pond outlet…
Applies To
Product(s):
WaterCAD, WaterGEMS, StormCAD, SewerGEMS, CivilStorm, PondPack,, SewerCAD
Version(s):
CONNECT Edition, V8i
Area:
Licensing
Problem
When attempting to set the default license to…
Product(s):
PondPack, StormCAD, CulvertMaster, FlowMaster
Version(s):
V8i, CONNECT Edition
Area:
General
Problem
Are Bentley's OpenFlows (water) products FEMA approved? If yes, which versions are FEMA approved?
Solution…
Product(s):
WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, StormCAD, HAMMER, WaterCAD
Version(s):
08.11.XX.XX, 10.XX.XX.XX
Area:
Layout and Data Input
Problem
The labels that are in my shapefiles are not…
Applies To
Product(s):
SewerGEMS, CivilStorm, PondPack
Version(s):
CONNECT Edition, V8i
Area:
Modeling
Original Author:
Jesse Dringoli, Bentley Technical Support Group
Problem
How can I enter…
Product(s):
WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD
Version(s):
CONNECT Edition, V8i
Area:
Modeling
Problem
When attempting to import data using ModelBuilder with a field…
Product(s):
WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack
Version(s):
CONNECT Edition, V8i
Area:
Installation
Problem
Can I install multiple versions of a Bentley OpenFlows product on a…
Product(s):
WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack
Version(s):
08.11.01.32 and greater
Area:
Output and Reporting
Problem
When changing the height multiplier in the properties of…
Product(s):
PondPack
Version(s):
10, V8i, CONNECT Edition
Area:
Layout and Data Input
Problem
How can I import hydrographs from Graphical HEC-1 to PondPack?
Solution - PondPack 10.x
Graphical HEC-1 exports every…
Applies To
Product(s):
PondPack, Civilstorm, SewerGEMS
Version(s):
V8i, CONNECT Edition
Area:
Dataset
Original Author:
Kathy Wiggins, Bentley Technical Support Group
Problem
Where does the…
Product(s):
WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD
Version(s):
08.11.XX.XX, 10.XX.XX.XX
Area:
Modeling
Problem
Under Engineering Libraries, different libraries show up with a lock…
Product(s):
WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD
Version(s):
08.11.XX.XX, 10.XX.XX.XX
Area:
Output and Reporting
Problem
How do you filter the FlexTables so only active…