• hello guys can anyone answer me for this point, what's different between specification beam (Release) and normal beam of the structure? the specification beam (release) will remove ?

    Dragon
    Dragon
    STAAD SPACE START JOB INFORMATION ENGINEER DATE 05-Dec-22 END JOB INFORMATION INPUT WIDTH 79 UNIT METER KN JOINT COORDINATES 1 0 0 0; 2 10 0 0; 3 0 5 0; 4 10 5 0; 5 0 0 10; 6 10 0 10; 7 0 5 10; 8 10 5 10; 9 1.66667 5 0; 10 3.33333 5 0; 11 5 5 0; 12 6…
    • 10 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Not a valid "Column base (CB)" joint

    Dan Calabro
    Dan Calabro
    I am attempting to assign and design gusset plate connections using Ram connection using data from a RSS model. When trying to assign a connection detail to a joint the error The joint composed by node "171" and members "120, 886" is not valid "Column…
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Combined footing tutorials

    Sulaiman Ade
    Sulaiman Ade
    Hello Everyone Please share with me the tutorials about a combined footings
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Design of Solid slab (Conventional slabs)

    Sulaiman Ade
    Sulaiman Ade
    Hello Everyone For a while, I was using an Advanced Concrete Design (RCDC) for the design of a solid slab. Today I tried to learn the RAM concept for the slab designs but I saw a design of strips that had never seen before (When I was using RCDC and…
    • Answered
    • over 2 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Error when importing from RAM Frame to RAM Connection

    Skylar Calhoun
    Skylar Calhoun
    Hello, I received this message when I went to import my RAM Frame analysis to RAM Connection. I noticed that my load combinations did not appear in RAM Connection, and I was puzzled why. I found that I could generate my loads, but my base plate design…
    • over 3 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • UC Ratio problem

    arul mani
    arul mani
    warehouse.zip wind calculation also in that folder.... try to fix this probem guys
    • over 4 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • how to get the loadings details in report????

    arul mani
    arul mani
    I have got my report, but there is no loading details like dead load, Wind loads and all... In report settings i have added Loadings, but its not showing.... Wt to do???? i want to see other load details. How to get that details?
    • over 4 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • UC Ratio problem

    arul mani
    arul mani
    Actually i need all members UC Ratio values. How to get all values???? Please guys guide me New folder (2).rar
    • over 4 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum