• This is WaterSight!

    Miguel Soares
    Miguel Soares
    Did you ever wish everyone in your team could see all of your enterprise system data in one common dashboard environment (SCADA, GIS, hydraulic model, customer billing and more)? Accessible anywhere, at any device, providing access to unlimited users…
    • 1 month ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Water Avançado CONNECT Edition - Português - Apostila e Dataset

    Douglas Miranda
    Douglas Miranda
    Apostila e dataset do treinamento WaterCAD/WaterGEMS Avançado para a versão CONNECT Edition Update 3 ou mais recente. O treinamento aborda o seguinte escopo: Workshop 1: Modelagem de Qualidade da Água Workshop 2: Estudo de descargas de redes Workshop…
    • WaterCAD WaterGEMS U3 Avançado.zip
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Files
  • SIG Webinar: Maximize Payback From Bentley Water Distribution System Model

    Angela Suarez
    Angela Suarez
    April 28, 2020 05:30 AM to 06:30 AM Eastern Time (US & Canada)
    Online
    Join industry colleagues for the new OpenFlows Special Interest Group virtual workshop, Maximizing Payback From Your Bentley Water Distribution System Model. This one-hour session includes a technology presentation as well as time to share questions....
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Calendar
  • SIG Virtual Workshop: OpenFlows – Emergency Response and Planning for Water Distribution

    Patsy Gant
    Patsy Gant
    OpenFlows Special Interest Group: Emergency Response and Planning for Water Distribution Host: Tom Walski, Bentley Fellow, Bentley Systems, Inc. Date/Time: April 9, 2020 at 11:00 A.M. EDT Register Now This OpenFlows Special Interest Group…
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • OpenFlows SIG Virtual Workshop: Maximizing Payback From Your Bentley Water Distribution System Model

    Patsy Gant
    Patsy Gant
    OpenFlows SIG: Maximizing Payback From Your Bentley Water Distribution System Model Host: Tom Walski, Bentley Fellow, Bentley Systems, Inc. 09 January 2019 - 11 AM EST Register Now Join industry colleagues for the new OpenFlows Special Interest…
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Format of input data of database connection in SCADAConnect

    Sushma Choure
    Sushma Choure
    Product(s): WaterGEMS, SewerGEMS Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Layout and Data Input Problem What should be the format of input data for importing the database connection using SCADA Connect? Solution The…
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Fix for WaterGEMS SCADA Historian query after upgrade

    Stephen Jackson
    Stephen Jackson
    This is a post to hopefully help someone else if they face a similar problem. When I upgraded to WaterGEMS Connect 10.02.01.06, I had a problem where my SCADA signals were no longer being recognized. Symptoms varied depending on how I tried to troubleshoot…
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • SampleDataExchanger.zip

    Wayne Hartell
    Wayne Hartell
    This zipped sample Visual Studio project is the final result from following through the steps in the Publishing Hydraulic Modeling Data to 3rd Party Systems document. If you do nothing other than follow the steps in the document you should arrive at a…
    • SampleDataExchanger.zip
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Files
  • DOCX

    DataIntegration User Guide

    Wayne Hartell
    Wayne Hartell
    A document that describes the usage and architecture of a data exchange framework that supports the creation of custom IPluginDataExchanger instances to allow users to create custom out-of-process data exchangers.
    • DataIntegration User Guide.docx
    • View
    • Hide
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Files
  • DOCX

    WaterGEMS to CSV User Guide (Batch Processing)

    Wayne Hartell
    Wayne Hartell
    This document describes, from an end user perspective, how to use the tools that are able to automatically publish WaterGEMS energy and hydraulic results to CSV format. This document focuses specifically on the feature that is able to batch process model…
    • WaterGEMS to CSV User Guide (Batch Processing).docx
    • View
    • Hide
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Files
  • DOCX

    WaterGEMS to CSV User Guide

    Wayne Hartell
    Wayne Hartell
    This document describes, from an end user perspective, how to use the tools that are able to automatically publish WaterGEMS energy and hydraulic results to CSV format.
    • WaterGEMS to CSV User Guide.docx
    • View
    • Hide
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Files
  • DOCX

    Publishing Hydraulic Modeling Data to 3rd Party Systems

    Wayne Hartell
    Wayne Hartell
    This document discusses the various features available in OpenFlows products that can be used to export data from models. The primary focus is on a tool that can be used to automatically publish results (and other) data in a near real-time context, particularly…
    • Publishing Hydraulic Modeling Data to 3rd Party Systems 2019-Mar-6.docx
    • View
    • Hide
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Files
  • Time tolerance setting in SCADAConnect Simulator

    Jesse Dringoli
    Jesse Dringoli
    Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack Version(s): Varies Environment: N\A Area: Output and Reporting The time tolerance setting in the new SCADAConnect…
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • WaterGEMS crashes if SCADA Datasource set for other than 24 hours

    Stephen Jackson
    Stephen Jackson
    When I set up SCADA signals with a 24-hour period, it works and I am able to view SCADA historical results in both the SCADA Signal preview menu or SCADA elements in the model. However, if I change to another time frame (such as 48 hours), WaterGEMS crashes…
    • Answered
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Smart Water Networks

    Yashodhan Joshi
    Yashodhan Joshi
    Product(s): WaterGEMS, WaterCAD, HAMMER Version(s): CONNECT Edition, V8i Area: Other Problem How do I incorporate “Smart Water” into my hydraulic model? Background “Smart Water” is a marketing slogan that refers to the…
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Install and license OpenFlows CONNECT Edition products without an internet connection

    Jesse Dringoli
    Jesse Dringoli
    Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm Version(s): CONNECT Edition Area: Installation Problem How can an OpenFlows product be installed and licensed on a computer without an internet…
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Scada signal relative speed factor

    Attila Bibok
    Attila Bibok
    Hi, Guys! It is extremely convenient to have the option to define the units for a database source: I can see that relative valve closure is present, and I can choose % or decimal. Unfortunately the same does not work with variable speed pumps…
    • Answered
    • over 6 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Using SCADAConnect Simulator

    Scott Kampa
    Scott Kampa
    Applies To WaterGEMS Version(s): 08.11.06.113 and higher Area: Modeling Original Author: Scott Kampa & Mark Pachlhofer, Bentley Technical Support Group This TechNote provides details on using the new SCADAConnect Simulator…
    • 1 day ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Viewing WaterGEMS model results in a SCADA HMI screen

    Jesse Dringoli
    Jesse Dringoli
    Do your water system Operators want to know what would happen in your system in a what-if situation or event, but don't have experience with using modeling software like WaterGEMS? Did you know what that the HMI Publishing feature in WaterGEMS can display…
    • over 6 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Blog
  • Will SCADA Results Publishing work with only OPC sources?

    Sushma Choure
    Sushma Choure
    Product(s): Bentley WaterGEMS, SewerGEMS Version(s): V8i, Connect Edition Area: Modeling Problem Description Will SCADA Results Publishing work with only OPC sources? Recommended Solution OPC is an interoperability standard…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • How can I publish my computed model results to a SCADA HMI?

    Yashodhan Joshi
    Yashodhan Joshi
    Product(s): WaterGEMS Version(s): CONNECT Edition, 08.11.06.58+ Area: Output and Reporting Background Starting with V8i SELECTseries 6 of WaterGEMS, the user can publish computed model results to a SCADA HMI (Human…
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • What date and time is used from a Real Time SCADA Signal?

    Jesse Dringoli
    Jesse Dringoli
    Product(s): Bentley WaterGEMS, WaterCAD Version(s): 08.11. Environment: N\A Area: Problem When using a Real Time Signal in SCADAConnect, what date / time does the program select from the data source…
    • over 7 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Maximizando o uso de Modelos Hidráulicos em Operação de Sistemas - SCADAConnect Simulator - WaterGEMS V8i SS5

    Douglas Miranda
    Douglas Miranda
    Veja nesse vídeo como integrar os resultados de modelos hidráulicos à telas de operação (CCO ou HMI), usando como intermédio um servidor OPC, usando o WaterGEMS SCADAConnect Simulator V8i SS5.
    • over 7 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki (Português)
  • SCADA Signal SQL Error

    Stephen Jackson
    Stephen Jackson
    I am using WaterGEMS SELECTSeries 6, build 08.11.06.113 32-bit. I am attempting to set up a SCADA Signal connection to a GE Proficy Historian database. The connection has been successfully established, and by following the instructions in the article…
    • Answered
    • over 7 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • The Bentley CONNECTION Event Chennai - Water, Wastewater, and Stormwater Modelling Application Seminar

    Tanay Kulkarni
    Tanay Kulkarni
    THE BENTLEY CONNECTION EVENT- Chennai : Hydraulics and Hydrology Section The Bentley CONNECTION Event in Chennai is scheduled for 9 th and 10 th of June, 2015. Senior Bentley colleagues will showcase the “CONNECT Edition” - The Next Generation of Infrastructure…
    • over 8 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
>