Product(s):
SewerGEMS, CivilStorm, StormCAD, SewerCAD, WaterGEMS, WaterCAD, HAMMER
Version(s):
CONNECT Edition
Area:
Modeling
Problem
When opening a model, the following error message is generated: "Expecting: ElementSymbologyGroupManager…
Product(s):
SewerGEMS, CivilStorm
Version(s):
CONNECT Edition
Area:
Modeling
Problem
When computing a model using the 2D Engine, error messages such as the following are generated in the User Notifications:
ReadInletsFromFile…
Product(s):
WaterCAD, WaterGEMS, HAMMER, StormCAD, SewerCAD, SewerGEMS, CivilStorm, PondPack
Version(s):
CONNECT Edition
Area:
Layout and Data Input
Problem
When loading a background layer an out of memory error is generated…
Product(s):
SewerGEMS, CivilStorm, StormCAD, SewerCAD
Version(s):
CONNECT Edition
Area:
Modeling
Background
The OpenFlows storm and sewer products include a number of features specific to modeling systems in the United Kingdom…
Product(s):
SewergEMS, CivilStorm
Version(s):
CONNECT Edition
Area:
Modeling
Problem
How do you set the SWMM Culvert Code when using the Explicit solver in SewerGEMS and CivilStorm?
If this is set incorrectly, user notifications…
Product(s):
SewerGEMS, CivilStorm, SewerCAD
Version(s):
CONNECT Edition
Area:
Modeling
Problem
The flow out of a pond does not following the rating curve for a composite outlet structure in an extended period simulation.…
Product(s):
SewerGEMS, CivilStorm, StormCAD, SewerCAD
Version(s):
CONNECT Edition
Area:
Modeling
Problem
When exporting a profile where taps are associated with conduits into the DXF format, the following error message is…
Hello,
I am recently working on a model consisting of a stormwater network connected to an open detention pond whose flow is discharged to another system connected to a retention pond downstream. The maximum HGL shall exceed the rim elevation of the…
Produto(s):
SewerGEMS, SewerCAD, StormCAD, CivilStorm
Versão(ões):
CONNECT Edition, V8i
Área:
Geral
Problema
Qual a diferença entre um Poço de Visista com tubo de queda e um Poço de Visisita normal?
Como faço para criar…
Produto(s):
Bentley WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, CivilStorm, StormCAD
Versão(ões):
V8i, Connect Edition
Área:
Layout e entrada de dados
Visão geral
Muitas vezes, é um desafio manter a sincronização entre…
Produto(s):
WaterCAD, WaterGEMS, HAMMER, StormCAD, SewerCAD, SewerGEMS, CivilStorm, PondPack
Versão(ões):
CONNECT Edition, V8i
Área:
Layout and Data Input
Visão Geral
Esta TechNote fornece dicas e técnicas para a importação…
Product(s):
PondPack, SewerGEMS, CivilStorm
Version(s):
CONNECT Edition, V8i, V10
Area:
Modeling
Problem
How does the Interconnected Pond Modeling (ICPM) algorithm work in PondPack, SewerGEMS or CivilStorm? (when selecting…
Product(s):
StormCAD, CivilStorm, SewerCAD, SewerGEMS, WaterGEMS, WaterCAD, HAMMER
Version(s):
CONNECT Edition
Area:
Modeling
Problem
When adding elements manually in the MicroStation-integrated versions of the OpenFlows…
Product(s):
StormCAD, SewerCAD, SewerGEMS, CivilStorm
Version(s):
10.04.00.158
Area:
Other
Problem
When attempting to re-open a model in the AutoCAD integrated mode which previously had an XREF attached, the following errors…
Product(s):
SewerGEMS, CivilStorm, StormCAD, SewerCAD
Version(s):
CONNECT Edition, V8i
Area:
Output and Reporting
Problem
Can I customize the annotation table seen at the bottom of the profiles? (the screenshot below shows…
OpenFlows SELECT Entitlements are specific features within a product that are only available to users with a current (active) subscription to OpenFlows products. There is no additional charge for SELECT Entitlements. To confirm you have access to OpenFlows…
Product(s):
SewerGEMS, CivilStorm
Version(s):
10.04.00.108 and later
Area:
Licensing
Problem
When opening SewerGEMS or CivilStorm, a message is generated that says: OpenFlows SELECT Entitlements Not Available.
OpenFlows…
Product(s):
SewerGEMS, CivilStorm
Version(s):
10.04.00.158
Area:
Modeling
Problem
Is it possible to report flow results on the 2D grid or along a given path?
Solution
As of version 10.04.00.158 (CONNECT Edition Update…
Product(s):
StormCAD, CivilStorm, SewerGEMS
Version(s):
CONNECT Edition, V8i
Area:
Calculations
How does "Correct for Partial Are Effects" work?
The "Correct for Partial Area Effects" Calculation Option is available with…
Product(s):
SewerGEMS, SewerCAD, StormCAD, CivilStorm
Version(s):
CONNECT Edition
Area:
Output and Reporting
Problem
How can I export the information seen in the profile annotation table?
Solution
There are a few options…