• Out of memory error when loading a background file

    Jesse Dringoli
    Jesse Dringoli
    Product(s): WaterCAD, WaterGEMS, HAMMER, StormCAD, SewerCAD, SewerGEMS, CivilStorm, PondPack Version(s): CONNECT Edition Area: Layout and Data Input Problem When loading a background layer an out of memory error is generated…
    • 29 days ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • How does the Interconnected Pond Modeling (ICPM) algorithm work

    Jesse Dringoli
    Jesse Dringoli
    Product(s): PondPack, SewerGEMS, CivilStorm Version(s): CONNECT Edition, V8i, V10 Area: Modeling Problem How does the Interconnected Pond Modeling (ICPM) algorithm work in PondPack, SewerGEMS or CivilStorm? (when selecting…
    • 3 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Default Engineering Library missing

    Jesse Dringoli
    Jesse Dringoli
    Product(s): SewerCAD, SewerGEMS, CivilStorm, StormCAD, WaterCAD, WaterGEMS, HAMMER, PondPack Version(s): CONNECT Edition, V8i Area: Libraries/Catalogs Problem The default engineering libraries appear to be missing…
    • 10 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • How to restore a backup copy of model files

    Larry Abla
    Larry Abla
    Applies To Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, FlowMaster, CulvertMaster Version(s): 10.xx.xx.xx, 08.11.xx.xx Area: Output and Reporting Original Author: Mark Pachlhofer…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Elements appear disconnected when zooming in

    Jesse Dringoli
    Jesse Dringoli
    Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD Version(s): CONNECT Edition, V8i Area: Output and Reporting Problem When zooming into the drawing, the elements seem to be disconnected…
    • 6 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Notifications about minimum or maximum elevations on the rating table not matching the headwater range

    Scott Kampa
    Scott Kampa
    Applies To Product(s): PondPack, SewerGEMS, CivilStorm Version(s): 08.11.01.56 (PondPack) 10.XX.XX.XX (other) Area: Modeling Original Author: Akshaya Niraula, Bentley Technical Support Group …
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Extracting Setup contents and prerequisites

    Larry Abla
    Larry Abla
    Applies To Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD Version(s): CONNECT Edition, V8i Area: Installation Problem In some cases, you may need to extract…
    • 7 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • User Notification: "The number of active pipes in this model exceeds the number of pipes allowed for your license"

    Jesse Dringoli
    Jesse Dringoli
    Applies To Product(s): WaterCAD, WaterGEMS, SewerGEMS, StormCAD, SewerCAD, PondPack, CivilStorm Version(s): CONNECT Edition, V8i Area: Licensing Original Author: Mark Pachlhofer, Bentley Technical Support…
    • 11 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Conduits being over-designed (oversized) during a design run on a system with very shallow slopes

    Yashodhan Joshi
    Yashodhan Joshi
    Product(s): StormCAD, CivilStorm, SewerGEMS Version(s): 08.11.03.77 and higher Area: Output and Reporting Problem Why is StormCAD over-designing the conduits during a design run on a system with very shallow slopes? (during…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Where can I find a manual (user guide)?

    Larry Abla
    Larry Abla
    Product(s): WaterCAD, WaterGEMS, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack, CulvertMaster Version(s): 08.11.XX.XX, 10..XX.XX.XX Area: Help and Documentation Solution For the OpenFlows products…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • How do I set a certain slope for my pipes when designing them?

    Yashodhan Joshi
    Yashodhan Joshi
    Product(s): SewerGEMS, CivilStorm, SewerCAD, StormCAD Version(s): 08.11.XX.XX Area: Modeling Problem How can I set a certain slope for my pipes when designing them? (fixed slope / known slope) Solution If you would…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Estimating a pump curve for a model

    Larry Abla
    Larry Abla
    Applies To Product(s): WaterGEMS, WaterCAD, SewerCAD, SewerGEMS, CivilStorm Version(s): 08.11.XX.XX Area: Layout and Data Input Problem How do I develop a pump curve if the only known information is…
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Chicago Storm IDF Curve

    Yashodhan Joshi
    Yashodhan Joshi
    Applies To Product(s): SewerGEMS, CivilStorm, PondPack Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Jesse Dringoli, Bentley Technical Support Group Problem How can I enter…
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Exporting model elements to shapefiles

    Larry Abla
    Larry Abla
    Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, StormCAD, HAMMER, WaterCAD Version(s): 08.11.XX.XX, 10.00.XX.XX Area: Output and Reporting Problem How do I convert my model elements into shapefiles? (for…
    • 27 days ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • "Is variable speed drive?" vs "Is variable speed pump?"

    Jesse Dringoli
    Jesse Dringoli
    Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, Version(s): V8i, CONNECT Edition Area: Layout and Data Input Problem What is the difference between the " Is variable speed drive? " check box in the "motor" tab of a pump…
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Error when opening model with DXF background (HRESULT, acdb19.dll, AecBase.dbx, etc)

    Yashodhan Joshi
    Yashodhan Joshi
    Product(s): SewerGEMS, WaterGEMS, StormCAD, SewerCAD, WaterCAD, CivilStorm, HAMMER Version(s): 10.XX.XX.XX, 8.11.XX.XX Area: Other Error or Warning Message When trying to open any model with a .dxf background layer or when…
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Catch basins imported as manholes from LandXML

    Larry Abla
    Larry Abla
    Applies To Product(s): StormCAD, CivilStorm, SewerGEMS Version(s): V8i, CONNECT Edition Area: Layout and Data Input Problem When importing a LandXML file, catchbasins (Civil3D inlets) are imported as manholes…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Changing units and decimal precision in Properties, Flextables, graphs or profiles

    Scott Kampa
    Scott Kampa
    Product(s): WaterGEMS, WaterCAD, CivilStorm, StormCAD, SewerGEMS, PondPack, SewerCAD, HAMMER, FlowMaster Version(s): CONNECT Edition, V8i Area: Layout and Data Input Problem How can I change the units, in the properties…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • How to Batch Morph nodes from one type to another

    Jesse Dringoli
    Jesse Dringoli
    Applies To Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, CivilStorm, StormCAD Version(s): CONNECT Edition, V8i SS4 and above Area: Modeling Original Author: Akshaya Niraula, Bentley Technical…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • User notification: "Conduit has a Stop control structure, but this is not supported next to the connected outfall element."

    Sushma Choure
    Sushma Choure
    Applies To Product(s): SewerGEMS, CivilStorm, SewerCAD Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Scott Kampa, Bentley Technical Support Group Problem Description How can the following…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Why does the gutter need to be defined in both the catch basin and gutter element?

    Jesse Dringoli
    Jesse Dringoli
    Product(s): StormCAD, CivilStorm,SewerGEMS, FlowMaster Version(s): 10.00.xx.xx, 08.11.xx.xx Area: Modeling Problem The gutter and catch basin elements both seem to have the same fields for defining whether the gutter…
    • over 5 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Understanding and Controlling Hydraulic Results in Output Files

    Jesse Dringoli
    Jesse Dringoli
    Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, StormCAD, CivilStorm Version(s): V8i, CONNECT Edition Area: Output and Reporting Introduction When a model is computed, hydraulic results are stored in separate files called…
    • 3 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Can ModelBuilder or LoadBuilder use shapefiles that have just a defined geographic coordinate system?

    Jesse Dringoli
    Jesse Dringoli
    Applies To Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, StormCAD, HAMMER, WaterCAD Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Layout and Data Input Original Author: Mark Pachlhofer…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • DXF or DGN layers missing in ModelBuilder

    Jesse Dringoli
    Jesse Dringoli
    Applies To Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD Version(s): CONNECT Edition, V8i Area: Layout and Data Input Original Author: Mark Pachlhofer, Bentley Technical…
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Pressure Junction vs Transition vs Manhole

    Ankit Kulkarni
    Ankit Kulkarni
    Product(s): SewerGEMS, SewerCAD, StormCAD, CivilStorm Version(s): CONNECT Edition, V8i Environment: N\A Area: Modeling Problem What are the differences between the pressure junction, transition and manhole…
    • 2 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
>