Produto(s):
SewerGEMS, SewerCAD, StormCAD, CivilStorm
Versão(ões):
CONNECT Edition, V8i
Área:
Geral
Problema
Qual a diferença entre um Poço de Visista com tubo de queda e um Poço de Visisita normal?
Como faço para criar…
Produto(s):
Bentley WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, CivilStorm, StormCAD
Versão(ões):
V8i, Connect Edition
Área:
Layout e entrada de dados
Visão geral
Muitas vezes, é um desafio manter a sincronização entre…
Hello,
When I check the manhole attribute table, it shows blank table as shown in the figure. How can I fix this?
(this is happening for existing models as well as newly created one.) rest of the components (Channels, cs) are visible in the attribute…
Hello everyone! I hope somebody would come to help regarding the issue that I have been encountering. I am facing issues when I try to import the shapefiles that I have created from SewerGEMS and has been reprojected and moved to correct it's location…
Hello,
I'm having following arrangement in my model.
CM 3 and CM1 is flowing to O2 and CM2 is assigned to O1 and simulated the model.
in the second scenario, I want to assign the the inflow time series of O2 to CM 2 as a Inflow (WET) collection…
We are developing a storm water model with top entry inlets ( Grate Inlets) connected to the Main Storm Water Drainage Line. In order to verify the inlet calculations, we have create a flowmaster sheet to compare the inlet calculations. After inputting…
Hello,
I'm simulating a storm network in sewergems platform. My network is connecting with a pond and the variation of HGL of the pond and the U/S node of the incoming channel is shown below.
I'm using explicit solver, with 6 sec routing time step…
Hello,
I am simulating a stormwater network (in sewergems) where I have channels, conduits, manholes, Ponds (3 nos), POS, Pumps. I can not simulate this in Implicit solver (as it takes hours and giving unstable results).
When I simulate in Explicit…
Produto(s):
WaterCAD, WaterGEMS, HAMMER, StormCAD, SewerCAD, SewerGEMS, CivilStorm, PondPack
Versão(ões):
CONNECT Edition, V8i
Área:
Layout and Data Input
Visão Geral
Esta TechNote fornece dicas e técnicas para a importação…
Hello, I am trying to export a surface model from Civil 3D to SewerGems for a university project but when I export the .xml file to SewerGems it is misaligned to to my background layer. The red outline should be shifted to the right to enclose the coloured…
Hola,
Tengo un modelo con cámaras con múltiples tuberías de salida y una de estas tiene una cota batea superior a la otra, es decir que una de las tuberías se comporta como una arranque. Al momento de ingresar los caudales que corresponden a cada tramo…
Hello, I am currently working on the construction and modeling of sewer networks using SewerGems software version 10.03.04.53. As a requirement of the client I have been asked to verify that the results obtained in the modeling comply with the Courant…
Product(s):
PondPack, SewerGEMS, CivilStorm
Version(s):
CONNECT Edition, V8i, V10
Area:
Modeling
Problem
How does the Interconnected Pond Modeling (ICPM) algorithm work in PondPack, SewerGEMS or CivilStorm? (when selecting…
Hello,
My network is having interconnected ponds and a outfall.
Arrangement is as shown in the below figure. For POSs, I have assigned weirs.
My question is , is it correct if I set the tailwater type for POS-1 to interconnected ponds and…
Product(s):
SewerCAD, SewerGEMS
Version(s):
CONNECT Edition
Area:
Calculations
Problem
When attempting to Validate or Compute a model with the GVF-Convex (SewerCAD) solver, the run fails and a user notification similar to…
Hello,
My network is having following arrangement (MH 1 upstream; O-1 is D/S).
As I'm aware, the upstream cross section governs the cross section of D/S channel. When there is a MH as the starting point of a channel, what is the channel section that…
Hello ,
Currently I am using sewergems (connect edition update 3) and I want to calculate the elevation difference between the ( conduit invert stop level) and (the downstream manhole invert level for the same conduit)
I tried you use user data extension…
I am using sewer gems to analyze an existing network along with a post development network, the system consists of gravity pipelines, lift stations and force mains and the all system discharging to an outfall, the steady state run is going well while…
Product(s):
StormCAD, CivilStorm, SewerCAD, SewerGEMS, WaterGEMS, WaterCAD, HAMMER
Version(s):
CONNECT Edition
Area:
Modeling
Problem
When adding elements manually in the MicroStation-integrated versions of the OpenFlows…
Product(s):
StormCAD, SewerCAD, SewerGEMS, CivilStorm
Version(s):
10.04.00.158
Area:
Other
Problem
When attempting to re-open a model in the AutoCAD integrated mode which previously had an XREF attached, the following errors…
Product(s):
SewerGEMS, CivilStorm, StormCAD, SewerCAD
Version(s):
CONNECT Edition, V8i
Area:
Output and Reporting
Problem
Can I customize the annotation table seen at the bottom of the profiles? (the screenshot below shows…
OpenFlows SELECT Entitlements are specific features within a product that are only available to users with a current (active) subscription to OpenFlows products. There is no additional charge for SELECT Entitlements. To confirm you have access to OpenFlows…
I am running a storm water model using the explicit engine and the runoff method utilized is EPA-SWMM Runoff. Once the headloss method is switched from Absolute to HEC-22 Energy ( Third Edition) with HEC-22 Benching Method Set to Full for the manholes…
Product(s):
SewerGEMS, CivilStorm
Version(s):
10.04.00.108 and later
Area:
Licensing
Problem
When opening SewerGEMS or CivilStorm, a message is generated that says: OpenFlows SELECT Entitlements Not Available.
OpenFlows…