• How to place a Tap on Blind Flange center in OPM CE

    Rahul Kumar
    Rahul Kumar
    Applies To OpenPlant CONNECT Edition Product(s): OpenPlant Modeler Version(s): CONNECT EDITION (10.08.00.51) Environment: Windows 8.1/10 (64 bit) Area: Placement Subarea: Placement Original Author: Soham…
    • over 1 year ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • Stormcad Model Builder: How to import Taps Referenced Link?

    TH GE
    TH GE
    I'm importing a large set of network data into stormcad from shp files. The shape files contain full information of Catch Basins, Taps, Outflows, Conduits, Laterals, Catchments including connectivity information (from node, to node, catchments' outfows…
    • Answered
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • Property Connection to a Diversion Link

    Jesse Dringoli
    Jesse Dringoli
    Product(s): SewerGEMS, SewerCAD, StormCAD, CivilStorm Version(s): 10.XX.XX.XX, 08.11.XX.XX Area: Modeling Problem When validating a model where a property connection element is connected to a diversion link the following…
    • over 5 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • RE: OPM SS6 - Threaded tap port

    Rahul Kumar
    Rahul Kumar
    Hello Tuan Le, You can request to open your closed SR at any point of time and you feel if there is still need of discussion. I will open it again for you. -Regards | Rahul Kumar
    • over 6 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Forum
  • RE: OPM SS6 - Cannot change pipeline with multiple tapping connection to another spec

    Rahul Kumar
    Rahul Kumar
    Hello Tuan Le, I have reproduced the case using default mEX-OPM & mA1-OPM. This is a known issue. Please create an SR so that we could update the same. HTH -Regards | Rahul Kumar
    • over 6 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Forum
  • RE: OPM SS6 - Cannot change pipeline with multiple tapping connection to another spec

    Rahul Kumar
    Rahul Kumar
    Hello Tuan Le, Can you please provide steps to enable us to reproduce this issue? -Regards | Rahul Kumar
    • over 6 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Forum
  • Introducing individual Property Connections to your model

    Craig Calvin
    Craig Calvin
    Have you ever wanted to add sanitary loads to a sewer model based on individual property data? Perhaps you have loading data provided for customers, or properties and would like to include it for a more detailed hydraulic model. Starting with the CONNECT…
    • over 7 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Blog
  • Using LoadBuilder to assign Property Connections to the nearest element while creating taps and/or laterals

    Larry Abla
    Larry Abla
    Product(s): SewerGEMS, SewerCAD Version(s): 10.00.00.40 and later Area: Modeling Introduction LoadBuilder can be used to assign isolated Property Connection elements to the nearest element by creating a tap and lateral…
    • 11 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • To Fix Welds on Olets in OpenPlant Modeler

    Rahul Kumar
    Rahul Kumar
    Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.581 Environment: Windows 7 (64 bit) | Windows 8 Area: Component Subarea: Graphics - Olets-Welds-Placement …
    • over 7 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki