• Ram connection using Hb force component instead of Hc as the axial force at the vertical brace connection's beam-to-column interface.

    Anurag E
    Anurag E
    At the vertical brace connection framing-to-beam-column junction , it appears that the Hb force component (required shear force on the gusset-to-beam connection) is considered as the axial force at the beam-to-column connection interface, rather than…
    • 28 days ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum