Product(s):
WaterGEMS, WaterCAD, SewerGEMS, SewerCAD,
Version(s):
V8i, CONNECT Edition
Area:
Layout and Data Input
Problem
What is the difference between the " Is variable speed drive? " check box in the "motor" tab of a pump…
Product(s):
WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD
Version(s):
CONNECT Edition, V8i
Area:
Modeling
Problem
When attempting to import data using ModelBuilder with a field…
Product(s):
WaterCAD, WaterGEMS
Version(s):
08.11.XX.XX, 10.XX.XX.XX
Area:
Output and Results
Problem
In the Post-Calculation Processor, I am unable to choose my pre-defined User Data Extension for the "Output Property" field…
Product(s):
WaterGEMS, WaterCAD, SewerGEMS, SewerCAD
Version(s):
08.11.XX.XX, 10.XX.XX.XX
Area:
Layout and Data Input
Problem
How can you distribute a lump sum demand over a large area? For example you have a single polygon…
Product(s):
WaterGEMS, WaterCAD
Version(s):
10.XX.XX.XX, 08.11.XX.XX
Area:
Data Input and Layout
Problem
I am getting a user notification that says "More than one VSPB cannot control the same control node". I'm…
Product(s):
WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack
Version(s):
CONNECT Edition, V8i
Area:
Installation
Problem
Can I install multiple versions of a Bentley OpenFlows product on a…
Product(s):
WaterGEMS, WaterCAD, HAMMER, StormCAD, SewerCAD, SewerGEMS, CivilStorm
Version(s):
10.00.XX.XX, 08.11.XX.XX
Area:
Modeling
Problem
When using annotations or color coding based on selection sets, or other features…
Product(s):
WaterGEMS, SewerGEMS, HAMMER
Version(s):
08.11.XX.XX, 10.XX.XX.XX
Area:
Layout and Input
Problem
How do I determine what projection, coordinate system or spatial reference a model has been set to? For example…
Product(s):
WaterGEMS, WaterCAD
Version(s):
08.11.XX.XX, 10.XX.XX.XX
Area:
Modeling
Problem
In the "Storage" section of the Scenario Energy Cost tool, what does the "Cost" represent for a tank and how is it calculated?
…
Product(s):
WaterGEMS, SewerGEMS, CivilStorm, StormCAD, SewerCAD, Hammer, WaterCAD
Version(s):
08.11.XX.XX, 10.XX.XX.XX
Area:
Layout and Data Input
Problem
Why doesn't my load use type field show up in the "population density…
Product(s):
WaterGEMS, WaterCAD, SewerCAD, SewerGEMS
Version(s):
CONNECT Edition, V8i
Area:
Layout and Data Input
Problem
Is there any way to graphically view which node each customer demand was allocated to, after running…
Product(s):
WaterGEMS,WaterCAD
Version(s):
V8i, CONNECT Edition
Area:
Output and Reporting
Problem
Is it possible to compare or visualize results between scenarios for example with annotations?
Solution
As of version…
Product(s):
WaterGEMS, WaterCAD, HAMMER
Version(s):
CONNECT Edition, V8i
Area:
Calculations
Problem
What is the process that WaterCAD and WaterGEMS use to compute headloss using the Darcy Weisbach friction method, considering…
Product(s):
WaterGEMS, WaterCAD
Version(s):
08.11.XX.XX and higher
Area:
Output and Reporting
Problem
When attempting to use the Post Calculation Processor tool, the following error occurs, or the desired results attribute…
Product(s):
WaterGEMS, WaterCAD
Version(s):
08.11.XX.XX, 10.XX.XX.XX
Area:
Modeling
Problem
When modeling a pump in WaterGEMS, is there a way to have the pump turn off, but still allow flow through the pump. Problem…
Product(s):
WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD
Version(s):
08.11.XX.XX, 10.XX.XX.XX
Area:
Modeling
Problem
Under Engineering Libraries, different libraries show up with a lock…
Product(s):
WaterGEMS, WaterCAD
Version(s):
CONNECT Edition, V8i
Area:
Output and Reporting
Problem
When attempting to validate a model in WaterGEMS or WaterCAD, the following red user notification appears:
"Failed to validate…
Product(s):
SewerCAD, SewerGEMs, CivilStorm, WaterCAD, Hammer, WaterGEMS
Version(s):
08.11.XX.XX, 10.XX.XX.XX
Area:
Calculations
Problem
User notification, "System Disconnected or Junction Disconnected because of element…
Product(s):
WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, CivilStorm, StormCAD, Hammer
Version(s):
08.11.XX.XX, 10.XX.XX.XX
Area:
Layout and Data Input
Problem
After a modelbuilder run, using GIS-ID as the label, when you open…
Product(s):
WaterGEMS, SewerGEMS, Hammer
Version(s):
CONNECT Edition, V8i
Area:
Layout and Data Input
Problem
When labeling features in the ArcMap platform, why does the label not show up for some elements?
Solution
1…
Product(s):
WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, Hammer, WaterCAD
Version(s):
08.11.XX.XX, 10.00.XX.XX
Area:
Other
Problem
Error using TRex (terrain extractor) tool
Could not load file or assembly…
Product(s):
WaterGEMS, WaterCAD, HAMMER
Version(s):
08.11.XX.XX, 10.XX.XX.XX
Area:
Output and Reporting
Problem
When looking at the total length of pipe in the Pressure Pipe Inventory report, the value is different…
Product(s):
WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD
Version(s):
08.11.XX.XX, 10.XX.XX.XX
Area:
Output and Reporting
Problem
How do you filter the FlexTables so only active…
Product(s):
WaterGEMS, WaterCAD, SewerGEMS, SewerCAD
Version(s):
08.11.XX.XX, 10.XX.XX.XX
Area:
Other
Problem
How can a hydraulic model be exported to Google Earth? (.kmz file)
Solution - MicroStation
Open the WaterGEMS…