Product(s):
WaterCAD, WaterGEMS, HAMMER, StormCAD, SewerCAD, SewerGEMS, CivilStorm, PondPack
Version(s):
V8 XM, V8i, CONNECT Edition
Area:
Modeling
Problem
How can I create a child scenario in a WaterObjects.NET project?…
Applies To
Product(s):
WaterGEMS, SewerCAD, WaterCAD
Version(s):
V8i, CONNECT Edition
Original Author:
Mark Pachlhofer, Bentley Technical Support Group
Problem
What is the difference between a "Clock Time…
Applies To
Product(s):
WaterCAD, WaterGEMS
Version(s):
CONNECT Edition, V8i
Area:
Modeling
Original Author:
Terry Foster, Bentley Technical Support Group
Problem
When using controls to open and close…
Applies To
Product(s):
HAMMER, WaterGEMS, WaterCAD, SewerGEMS, SewerCAD
Version(s):
V8i, CONNECT Edition
Area:
Modeling
Original Author:
Scott Kampa, Bentley Technical Support Group
Problem…
Product(s):
WaterGEMS, WaterCAD
Version(s):
CONNECT Edition, V8i
Area:
Modeling
Problem
How can I calibrate a hydraulic model based on hydrant flow tests?
Solution
Hydrant flow test data can be used to calibrate…
Applies To
Product(s):
WaterGEMS, WaterCAD
Version(s):
V8i, CONNECT Edition
Area:
Layout and Data Input
Original Author:
Jesse Dringoli and Mark Pachlhofer, Bentley Technical Support Group
Introduction
This…
Applies To
Product(s):
HAMMER
Version(s):
V8i, CONNECT Edition
Area:
Modeling
Original Author:
Jesse Dringoli, Bentley Technical Support Group
Problem
How can a vertical turbine pump, or a…
Product(s):
WaterGEMS, WaterCAD, HAMMER
Version(s):
V8i, CONNECT Edition
Area:
Layout and Data Input
Problem
How can I use patterns to change the pump speed over time (or turn it on/off based on time), or reservoir hydraulic…
Product(s):
WaterGEMS, WaterCAD
Version(s):
10.XX.XX.XX, 08.11.XX.XX
Area:
Calculations
Problem
How do pressure dependent demands (PDD) handle a situation where the pressure drops all the way to zero?
I'm seeing an odd…
Product(s):
WaterObjects.NET
Version(s):
08.11.00.05
Area:
Other
Problem
WO.NET error when running a sample model: Could not load file or assembly ...
For example:
Could not load file or assembly 'Haestad.SQLite…
Applies To
Product(s):
WaterCAD, WaterGEMS
Version(s):
CONNECT Edition, V8k
Area:
Calculations
Original Author:
Scott Kampa, Bentley Technical Support Group
Problem Description
Is WaterGEMS/WaterCAD capable…
Product(s):
WaterGEMS, Hammer, WaterCAD, SewerGEMS, CivilStorm
Version(s):
CONNECT Edition, V8i
Area:
Layout and Data Input
Problem
When trying to import an EPANET .INP file into WaterGEMS or WaterCAD or an SWMM 5 .INP file…
Product(s):
WaterGEMS, WaterCAD, HAMMER, SewerCAD, SewerGEMS, StormCAD, CivilStorm, PondPack
Version(s):
V8i, CONNECT Edition
Area:
Installation
Problem
When trying to open AutoCAD one of the following error message occurs…
Applies To
Product(s):
WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD
Version(s):
CONNECT Edition, V8i
Area:
Installation
Problem
In some cases, you may need to extract…
Product(s):
WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm
Version(s):
08.11.XX.XX
Area:
Output and Reporting
Problem
Scenario 1
After creating a Project FlexTable you may decide that you want to…
Product(s):
WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD
Version(s):
08.11.XX.XX, 10.XX.XX.XX
Area:
Output and Reporting
Problem
How do you filter the FlexTables so only active…
Product(s):
WaterGEMS, WaterCAD, StormCAD, SewerCAD, SewerGEMS, CivilStorm, PondPack, HAMMER
Version(s):
10.00.xx.xx, 08.11.xx.xx
Area:
Layout and Data Input
Problem
What file types are supported for background layers for the…
Product(s):
SewerCAD, WaterCAD, WaterGEMS
Version(s):
V8i, CONNECT Edition
Area:
Layout and Data Input
Problem
Is it possible to open or import a SewerCAD or SewerGEMS (.SWG / .SWR / .STSW) model in WaterCAD or…
Product(s):
WaterGEMS, WaterCAD, HAMMER
Version(s):
CONNECT Edition, V8i
Area:
Modeling
Problem
I have several PRV's in my model and most of the PRV's have a 2" loop (bypass). Should I try to model the bypass, or should it…
Product(s):
WaterGEMS, SewerGEMS, WaterCAD, SewerCAD, StormCAD, CivilStorm, HAMMER
Version(s):
10.XX.XX.XX, 08.11.XX.XX
Area:
Layout and Data Input
Problem
The pattern that I have assigned to my reservoir, demand or sanitary…
Product(s):
WaterGEMS
Version(s):
CONNECT Edition, V8i
Area:
Modeling
Overview
The purpose of this TechNote is to discuss common steps to design new pipe layouts and pipe rehabilitation projects using Darwin Designer in Bentley…
Product(s):
WaterGEMS
Version(s):
CONNECT Edition, V8i
Area:
Modeling
Overview
The purpose of this technote is to explain how to calibrate a model using Darwin Calibrator in Bentley WaterGEMS. Additional information can be…
Applies To
Product(s):
WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, HAMMER
Version(s):
CONNECT Edition, V8i
Area:
Modeling
Original Author:
Scott Kampa, Bentley Technical Support Group
Problem