• Sharing Queries for use in other models

    Jesse Dringoli
    Jesse Dringoli
    Applies To Product(s): WaterCAD, WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER Version(s): CONNECT Edition, V8i Area: Other Original Author: Mark Pachlhofer, Bentley Technical…
    • 9 days ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Why is my license listed as "Not Available" under the extensions (Customize > Extensions) in ArcMap?

    Jesse Dringoli
    Jesse Dringoli
    Product(s): WaterGEMS, SewerGEMS, Hammer Version(s): CONNECT Edition, V8i Environment: ArcMap Area: Licensing Problem When I go to view the extensions (Customize > Extensions) in ArcMap I see the license for WaterGEMS…
    • 13 days ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Is there a way to model a rectangular pipe in WaterCAD, WaterGEMS or HAMMER?

    Jesse Dringoli
    Jesse Dringoli
    Applies To Product(s): WaterGEMS, WaterCAD, HAMMER Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Scott Kampa, Bentley Technical Support Group Problem Is there a way to model…
    • 5 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Is it possible to delete an element from one scenario, but retain it in another?

    Jesse Dringoli
    Jesse Dringoli
    Applies To Product(s): WaterCAD, WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Scott Kampa, Bentley Technical Support Group …
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Error Installing: "Error 1935. An error occurred during the installation of assembly"

    Larry Abla
    Larry Abla
    Applies To Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack Version(s): CONNECT Edition, V8i Area: Installation Problem When installing a Bentley Hydraulics and Hydrology…
    • 11 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • How can I reverse the profile view?

    Scott Kampa
    Scott Kampa
    Product(s): SewerCAD, SewerGEMS, StormCAD, CivilStorm, WaterGEMS, WaterCAD, HAMMER Version(s): CONNECT Edition, V8i Area: Output and Reporting Problem How can i reverse the direction of profile view? Problem ID#: 41748 …
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Pipes not merging when using Skelebrator with series pipe merging

    Jesse Dringoli
    Jesse Dringoli
    Product(s): WaterGEMS, WaterCAD, HAMMER Version(s): CONNECT Edition Area: Modeling Problem When using the Skelebrator feature Series Pipe Merging, two pipes that appear to satisfy the parameters entered are not…
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Error opening existing model: "Parameter name: Index was out of range"

    Yashodhan Joshi
    Yashodhan Joshi
    Product(s): SewerGEMS, SewerCAD, CivilStorm, StormCAD, WaterGEMS, WaterCAD, HAMMER Version(s): 10.00.XX.XX, 08.11.XX.XX Area: Modeling Error or Warning Message When opening a model, the following error message occurs: "Specified…
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • "Access to the path... is denied" in log file

    Jesse Dringoli
    Jesse Dringoli
    Applies To Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, StormCAD, HAMMER,, WaterCAD Versions: All Original Author: Mark Pachlhofer, Bentley Technical Support Group Problem When I look…
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Using Controls to change pump speed

    Jesse Dringoli
    Jesse Dringoli
    Applies To Product(s): WaterCAD, WaterGEMS, HAMMER, SewerCAD Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Jesse Dringoli, Bentley Technical Support Group Problem How can…
    • 3 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Inserting or laying out pipe bends

    Jesse Dringoli
    Jesse Dringoli
    Product(s): Bentley WaterCAD, WaterGEMS, HAMMER, StormCAD, SewerCAD, SewerGEMS, CivilStorm, PondPack Version(s): V8i, CONNECT Edition Area: Layout and Data Input Problem How can I lay out a bend in a pipe when working…
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Using Tank Low and High Alarm

    Scott Kampa
    Scott Kampa
    Product(s): WaterGEMS, WaterCAD, Hammer Version(s): V8i, CONNECT Edition Area: Layout and Data Input Problem What is the purpose of the tank attributes "Use Low Alarm" and "Use High Alarm"? Solution If you set the "Use…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Citect is not available when running as 64-bit

    Jesse Dringoli
    Jesse Dringoli
    Applies To Product(s): WaterGEMS Version(s): V8i, CONNECT Edition Area: Modeling Original Author: Akshaya Niraula, Bentley Technical Support Group Problem The following error occurs when trying to connect…
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Modeling a Connection to an Existing System

    Sushma Choure
    Sushma Choure
    Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD Version(s): V8i, CONNECT Edition Area: Modeling Original Authors : Scott Kampa, Jesse Dringoli, Tom Walski Background If you are modeling only a portion of a larger…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Modeling a submersible pump

    Jesse Dringoli
    Jesse Dringoli
    Applies To Product(s): HAMMER, WaterGEMS, WaterCAD, SewerGEMS, SewerCAD Version(s): V8i, CONNECT Edition Area: Modeling Original Author: Scott Kampa, Bentley Technical Support Group Problem…
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Modeling a vertical turbine or multi-stage pump

    Jesse Dringoli
    Jesse Dringoli
    Applies To Product(s): HAMMER Version(s): V8i, CONNECT Edition Area: Modeling Original Author: Jesse Dringoli, Bentley Technical Support Group Problem How can a vertical turbine pump, or a…
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • What is the purpose of the 'Accuracy' Calculation option?

    Jesse Dringoli
    Jesse Dringoli
    Product(s): WaterGEMS, WaterCAD, HAMMER, SewerCAD, SewerGEMS Version(s): V8i, CONNECT Edition Area: Calculation options Problem What is the purpose of the 'Accuracy' Calculation Option (listed under the Hydraulics section…
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Extracting Setup contents and prerequisites

    Larry Abla
    Larry Abla
    Applies To Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD Version(s): CONNECT Edition, V8i Area: Installation Problem In some cases, you may need to extract…
    • 7 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Using controls to change the target pressure / HGL setting of a variable speed pump

    Sushma Choure
    Sushma Choure
    Product(s): WaterCAD, WaterGEMS Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Modeling Problem Is it possible to add a control to a variable speed pump (VSP) that will change the target pressure setting based on a condition…
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • "Unexpected drawing version..." error when opening model

    Sushma Choure
    Sushma Choure
    Product(s): SewerCAD, StormCAD, WaterCAD, WaterGEMS, CivilStorm, Hammer Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Data Input and Modeling Error or Warning Message "Unexpected drawing version: 39" (or similar) error or "Object…
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Can you run a VSP with a control node and logical controls at the same time?

    Jesse Dringoli
    Jesse Dringoli
    Product(s): WaterGEMS, WaterCAD, SewerCAD Version(s): CONNECT Edition, V8i Area: General Problem Can you run a VSP with a Control node and Logical Controls at the same time? Solution VSP Interactions with…
    • 9 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • How do you associate a pump to a pump station?

    Sushma Choure
    Sushma Choure
    Product(s): WaterCAD, WaterGEMS, SewerGEMS, SewerCAD Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Layout and Data Input Problem How do you associate a pump to a pump station? What is the difference between a pump…
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Filtering a Flextable on Zone = "None"

    Sushma Choure
    Sushma Choure
    Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Modeling Problem How can you filter a flextable on Zone = "None"? Problem ID#: 46478…
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Exporting hydraulic models to Google Earth KMZ

    Sushma Choure
    Sushma Choure
    Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Other Problem How can a hydraulic model be exported to Google Earth? (.kmz file) Solution - MicroStation Open the WaterGEMS…
    • over 4 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • What is the difference between Darcy-Weisbach roughness coefficients e and f, and Bed Roughness Ks or K?

    Jesse Dringoli
    Jesse Dringoli
    Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, CivilStorm Version(s): CONNECT Edition, V8i Area: Modeling Problem Difference between the coefficients e and f , when using the Darcy-Weisbach friction…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
>