When the user is trying to create a new template, the template editor window automatically minimizes, and, if it's maximized again, it appears greyed out and is unresponsive. Note that OpenBridge Modeler is working as designed as the user must follow…
Hi,
I have lost my tool settings dialog box and properties window box. I used to have them docked and now they are missing.
I have looked behind windows, underneath views etc and no luck. I have followed the instructions in this video ( https:/…
The RM Bridge Main Screen has all the necessary functions for the graphic presentation of the model on the back of the main graphic screens of the GUI. When no other input/output window is open, this is the Model View. As shown in the images below, there…
At the Recalc Window: 3. Dynamics/Iterations: 2. Iteration control , the definition of the convergence parameters for non-linear iterative structural deformation analysis is set. The default values ensure in general a fast and sure convergence to an extremely…
RM Bridge Enterprise Recalculation Window has, inside the Advanced Options, the possible Dynamics / Iterations options to be set up; and, as shown in the screenshot below, they settings 2. Iteration Control , includes an option Used processors (threads…
The Recalc Window 2. Extended Settings: 2. Pre-stressing allows the users to set additional definitions for the calculations related to the stressing of tendons:
Update CS Values: (-) duct areas : The area of the ducts is excluded in a new cross-section…
Is there a way to dock horizontal toolbars to the right? They keep snapping to the left and this is not where I want to position them. I want the AccuSnap Coordinates and 3D input to dock to the bottom right.
Hello,
I need help with placing a window in a wall that doesn't touch the floor level.
All the pink figure in the following picture is one room obtained by merging several rooms from different levels.
When level 1 is active, the window probably…
The relevant parameters for dynamic calculations in RM Bridge Enterprise are set in the Recalculation Window at the Dynamics / Iteration options within the Dynamics group. They are:
g - gravity (constant acceleration of gravity)
dt - time step (length…
RM Bridge Enterprise Recalculation Window has, inside the Advanced Options, the possible Dynamics / Iterations options to be set up, as shown in the screenshot below, they include:
Dynamics
Iteration Control
Cross-Section Integration
Eqn. Solver…
RM Bridge Enterprise has many possible options to be set in the Recalculation window . If the button Show Schedule Variants and Advanced Options , highlighted in red below, is selected, we can see the Recalculation options main menu with:
Structure…
Hi All,
If you open a drawing that has been created in AutoCAD (DWG), that has viewports, how do change (move) the cutting plane?
In AutoCAD you enter the windows and then with the 3dclip command you move the planes up and down.
What is the…
Product(s):
Hevacomp Mechanical and Electrical Designer
Version(s):
V8i (N/A)
Environment:
N/A
Area:
N/A
Subarea:
N/A
Problem
To help with a support solution, you may need to open a Command…
Product(s):
AECOsim Building Designer
Version(s):
V8i 08.11.09.866
Environment:
N/A
Area:
Architectural Design
Subarea:
Windows
Problem
How to create your own window with a rebate?
Solution…
It should not matter which version of MicroStation V8i but when you drag each dialog to be docked to the side of the application window you should see separate arrow to the left and right indicating where it is going to be docked. Once the dialog has…
Product(s):
Hevacomp Design Database
Version(s):
V8i (N/A)
Environment:
N/A
Area:
N/A
Subarea:
N/A
Overview
When adding a window or door to a surface, you may receive a "Window is too small…
I have an AddIn whose UI is a .NET Windows Form. The form's default behaviour is to sink below MicroStation's main window when the user clicks in any MicroStation window or dialog. If I call Form.TopMost() , the form sits permanently right on top of all…
Product:
MicroStation
Version:
V8, XM, V8i, CONNECT
Environment:
N\A
Area:
GUI
Subarea:
Dialogs
Problem
The dialog box for any tool can get stuck either under the menubar or off the screen…
Problem:
We need a quick, easy method to arrange (and save the layout of) multiple view windows.
Each user may have a preferred set of views open, and preferred arrangement.
There really is no one RIGHT way, much depends on how user is comfortable…
Applies To
Product(s):
AECOsim Building Designer
Version(s):
08.11.09.747
Environment:
N\A
Area:
DataGroup System
Subarea:
Add or Modify Instance Data
Original Author…
This has a few tricky tricks in it, so it might take a while to digest, but you might like them!
See what you make of this:
transaction graphChange 'Add bsplineSurface01, bsplineSurface02, height, LRshift, point01, point02, point03, point04,…