• Analysis of Cable-Membrane Structures

    Juan Trueba
    Juan Trueba
    Analysis of Cable-Membrane Structures (a) (b) Figure 1 Cable-membrane structures: (a) typical beach shelter (b) Foshan Stadium, China Cable-membrane structures are lightweight structures that can span large distances…
    • 8 months ago
    • RAM | STAAD | ADINA
    • RAM | STAAD | ADINA Wiki
  • Torre de comunicaciones arriostra

    Samuel Arturo Alejo Felix
    Samuel Arturo Alejo Felix
    Hola, estoy modelando una torre arriostrada (ventada o atirantada) en Ram elements, pero no se si estoy modelando los cables correctamente. He colocado el elemento como solo axial solo Tension y articule para evitar momentos y agregue una tension incial…
    • over 1 year ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • 7. CSB - Cable Stayed Bridge

    MarcosBeier
    MarcosBeier
    The seventh option in the RM Bridge Enterprise Training Examples, 7. CSB - Cable Stayed Bridge has the datasets and an explanatory document for both a. DIN & b.EC modeling, analysis and design of a complete basic 4 spans CSB reference project. It can…
    • over 1 year ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
  • Filter a Cable Report in OpenUtilities Substation CONNECT

    Satish Saptasagar
    Satish Saptasagar
    Product(s): OpenUtilities Substation CONNECT Edition Version(s): 10.00.XX.XX to 10.09.XX.XX Environment: N/A Area: Reports_Output Features Subarea: Reporting How can users filter cable reports…
    • over 2 years ago
    • OpenUtilities
    • OpenUtilities Wiki
  • Filter a Cable Report in Promis.e CONNECT

    Satish Saptasagar
    Satish Saptasagar
    Product(s): Promis.e CONNECT Edition Version(s): 10.00.XX.XX to 10.07.XX.XX Environment: N/A Area: Reports_Output Features Subarea: Reporting How can users filter cable reports in Promis.e CONNECT…
    • over 2 years ago
    • OpenUtilities
    • OpenUtilities Wiki
  • How to import Cable UDA using Cable list import tool

    Aadarsh Tale
    Aadarsh Tale
    Product(s): Bentley Raceway & Cable Management Version(s): CONNECT Edition (10.04.00.25) Environment: N/A Area: User Defined Attributes (UDA) Subarea: Cable UDA O riginal Author: Vikrant Kale Background…
    • over 2 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • Cable Rod failing due to KL/r?

    Pascual Mauricio
    Pascual Mauricio
    Hello all, I have a Canopy model with cable stays modeled as solid bars. They are currently failing due to "L/R-EXCEEDS" - I believe this refers to KL/r compression analysis. I do not understand why STAAD is analyzing the rods under compression when…
    • over 4 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Why is tension in cable not activating?

    Katia Patro
    Katia Patro
    I am trying to do an analysis with small glass facade held by cables. However I am getting a huge deflection in the middle of the facade. Even I try to increase the tension in cable, it is still giving a huge unrealistic deflection. Maybe someone can…
    • Answered
    • over 4 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Hevacomp Electrical systems - Twin and earth cable for 3phase

    Luke Andrews
    Luke Andrews
    Hi, I am working on a project where a contractor has used 2No 4mm twin and earth cables to feed a 32A TP&N 5pin socket. I need to run a cable calc to reflect his installtion. Is it possible, using Hevacomp Connect, to run a cable calc based on the…
    • over 4 years ago
    • Hevacomp
    • Hevacomp Forum
  • Compression coming in cable. How to get around it?

    Sameer Nami
    Sameer Nami
    I am trying to make a cable system which which is originally a tension rod system. However i want to include the prestress in the model therefore I am using cable. I have applied prestress to different region of the structure gradually but still one…
    • Answered
    • over 5 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Large loss of PSCC across first leg of circuit from Transformer to Main switchboard

    Andy Leask
    Andy Leask
    Afternoon all I hope someone can shed some light on what i think is a problem with hevacomp connect, i am currently working on a large project and at the transformer, we have a fault current of 24kA but 10m upstream we have a fault current of 7.9kA…
    • Answered
    • over 5 years ago
    • Hevacomp
    • Hevacomp Forum
  • Multiple conductors in parallel

    Adam Maye
    Adam Maye
    I am drawing an installation which has several cable runs where multiple cables are connected in parallel. e.g. 2 x 185mm single core AWA per pole, or 2 x 95mm 4 core SWA. Please can you advise the recommended way to represent these in Connect?
    • Answered
    • over 6 years ago
    • Hevacomp
    • Hevacomp Forum
  • Derate XLPE cables to run to a maximum of 70 deg instead of 90 deg

    Martin Griffin
    Martin Griffin
    Hi, Please can anyone tell me the best way to derate XLPE cables to run to a maximum of 70 degrees instead of 90? Thanks
    • over 6 years ago
    • Hevacomp
    • Hevacomp Forum
  • RE: cable calcs

    Shane Regan
    Shane Regan
    Hi Ian, I would firstly advise making sure that your software is up to date so that you are availing of all cable types - in particular please ensure that you have the latest Content Pack installed. This is Content pack 3 which can be downloaded as detailed…
    • over 7 years ago
    • Hevacomp
    • Hevacomp Forum
  • Underground cables appear to be undersized

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Connect Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Problem Underground cables appear to be undersized when the calculation is run Solution You should…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Wiki
  • Drawing cables with extrusion along path problem.

    Stefanita PLUTEANU
    Stefanita PLUTEANU
    Hello, First i will start with how i figured to draw cables in AECOsim building designer. I draw with smart line arcs and line segments then i unite them with complex chain tool, after this step i draw a circle with my diameter and use the tool solid…
    • over 8 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon | Forum
  • Non-Linear Cable Analysis of a steel canopy in STAAD

    Jack Thomson
    Jack Thomson
    Hello everyone, I have this problem. The structure is a steel cantilever canopy supported by cables. What I understand is that, I need to model the cables as tension only members, and to use the advanced non-linear solver (done). what I want to do is…
    • over 8 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum
  • Filter a Cable Report

    Matt_P
    Matt_P
    Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.73 Environment: N/A Area: Reports_Output Features Subarea: Reporting How do I filter the built-in cable reports? Background…
    • over 6 years ago
    • OpenUtilities
    • OpenUtilities Wiki
  • Fabric sheeting on top of a structure

    Oruba
    Oruba
    Hi, I'm modeling a structure that consists of a series of concrete columns spreaded on the perimeter of a rectangular shape building, and attached to a channel concrete caps that running on top of perimeter columns, then the channel beam is connected…
    • model.JPEG
    • View
    • Hide
    • over 14 years ago
    • RAM | STAAD | ADINA
    • RAM | STAAD Forum