• ASME VIII

    Marc Brancourt
    Marc Brancourt
    From what date will the 2023 version be taken into account? Having Stamp U contracts, we are obliged to use this version as of January 1, 2024
    • 11 days ago
    • AutoPIPE
    • AutoPIPE Vessel Forum
  • Notificação do usuário: "Pump cannot deliver flow or head"

    Luca Santos Billis
    Luca Santos Billis
    Aplica-se a Produto(s): WaterGEMS, WaterCAD, HAMMER, SewerCAD, SewerGEMS, CivilStorm Versão(ões): CONNECT Edition, V8i Área: Cálculos Autor Original: Terry Foster, Grupo de Suporte Técnico da Bentley Problema…
    • 26 days ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki (Português)
  • 03. Where to change the values for Clamp Wb and Wba for BS En 13445 2021 using AutoPIPE Vessel?

    Mike Dattilio
    Mike Dattilio
    Answer: These values are not user input values or calculated values by the program. These values are referenced by the Allowable Bolt Load table at Room Temp or At Design Temp for the clamped flanges. One can review the referenced table in AutoPIPE…
    • 1 month ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 24. Limpet Coil Moment of Inertia calculation verification using AutoPIPE Vessel and Microstation

    Mike Dattilio
    Mike Dattilio
    Review and prove 2 different calculations for Limpet coils: Problem #1: Given the following Confirm AutoPIPE Vessel Moment of Inertia calculation and compare to Microstation AutoPIPE Vessel: Microstation Problem #2: Given the following…
    • 1 month ago
    • AutoPIPE
    • AutoPIPE Wiki
  • Mass is a scalar value!

    MarcosBeier
    MarcosBeier
    A common error for beginners in structural dynamics is to forget that mass is a scalar value. Therefore, the masses input listed below must have the same value in all three global axis directions ! Moreover, the user should remember that the l oads of…
    • 2 months ago
    • LARS | LEAP | OpenBridge | OpenTunnel | RM
    • LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
  • F. General

    Mike Dattilio
    Mike Dattilio
    01. Why there are significantly higher values in wind loading in some particular sections of vessels despite the model no platforms / ladders or other equipment? 02. How to check for bolt load calculations for longitudinal saddle load generated during…
    • 1 month ago
    • AutoPIPE
    • AutoPIPE Wiki
  • B. As Per ASME Section VIII

    Tanaji Gaikwad
    Tanaji Gaikwad
    01. Does the calculation of a body flange according to ASME VIII, div 1, consider a rigidity criterion in an AutoPIPE Vessel model? 02. What is the theory being C-factors derivation as per UG-34 in AutoPIPE Vessel? 03. How AutoPIPE Vessel Calculate…
    • 5 days ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 01. Why there are significantly higher values in wind loading in some particular sections of vessels despite the model no platforms / ladders or other equipment?

    Tanaji Gaikwad
    Tanaji Gaikwad
    Applies To Product(s): AutoPIPE Vessel Version(s): ALL Area: General Date Logged & Current Version June 2023 43.01.01.011 Problem: Why there are significantly higher values in wind loading in some particular…
    • 3 months ago
    • AutoPIPE
    • AutoPIPE Wiki
  • Soluções de problemas para as notificações de "Network Unbalanced" ou "Cannot solve network hydraulic equations"

    Luca Santos Billis
    Luca Santos Billis
    Produto(s): WaterGEMS, WaterCAD Versão(ões): CONNECT Edition, V8i Área: Modelagem Problema Como um usuário pode corrigir a mensagem de erro do WaterGEMS ou WaterCAD " Unbalanced Network " ou " Cannot solve network hydraulic…
    • 4 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki (Português)
  • Output results required error and changing material error

    Krzysztof Skrzypek-Markiewicz
    Krzysztof Skrzypek-Markiewicz
    Dear Colleagues, During my preliminary calculations of vertical vessel in Vessel (no nozzles, basic settings, only trays and packing defined for rough approximation of mass distribution, some wind parameters), I have encountered an error. Some of…
    • Answered
    • 4 months ago
    • AutoPIPE
    • AutoPIPE Vessel Forum
  • 03. The program do not finish the calculation

    Tanaji Gaikwad
    Tanaji Gaikwad
    Applies To Product(s): AutoPIPE Vessel Version(s): ALL Area: General Date Logged & Current Version June 2023 41.01.01.011 Problem: The program do not finish the calculation Solution: This could be happen…
    • 3 months ago
    • AutoPIPE
    • AutoPIPE Wiki
  • Non zero cohesion and tensile strength

    Dan Sandilands
    Dan Sandilands
    Is there an official Plaxis reference or literature reference supporting the use of non zero cohesion and tensile strength (eg 1 kPa), to improve numerical calculation?
    • Answered
    • 5 months ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Forum
  • 15. How are DNVGL-F101 offshore 2017 ASD calculations per GrT1P1 performed in AutoPIPE?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Stress Calculations Date Logged & Current Version April 2023 23.00.00.230 Problem: How does AutoPIPE calculate DNVGL-F101 offshore 2017 ASD (Allowable Stress…
    • 6 months ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 03. Why when changing the mill tolerance does the JSME code results not change when using AutoPIPE?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Allowable Date Logged & Current Version Aug.2021 12.06.00.48 Problem: Changing 'Mill Tol' value does not change the code compliance results for JSME code…
    • 8 months ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 047. Do the horizontal seismic actions in AutoPIPE Vessel come from the full weight in case (+), and in case (-) come from a reduced weight? (reduced = 60% of weight)

    Mike Dattilio
    Mike Dattilio
    Answer: The simple answer is - full weight is NOT 60% of weight. Referencing model from SR provided by the user: " Heater _273_OF 43-9146_RC3 ". Run the file and generate the report. Now go to the case 11. The transverse reaction total…
    • 8 months ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 06. Confirm calculation of Flange dia with specified tolerance and corrosion settings using AutoPIPE Vessel

    Tanaji Gaikwad
    Tanaji Gaikwad
    Example: In the flanges of this equipment, a 1 mm tolerance and 1 mm corrosion margin have been indicated, but in the calculations, the thickness "corroded dimensions" only subtracts 1 mm, for example, flange 20.04, nominal thickness 40 mm, calculation…
    • 3 months ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 02. How to calculate Von Mises category combinations allowable using AutoPIPE?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Date Logged & Current Version Dec 2022 12.08.03.015 Problem: How to calculate Von Mises category combinations allowable using AutoPIPE? Solution: Open…
    • 10 months ago
    • AutoPIPE
    • AutoPIPE Wiki
  • Calculations

    Tanaji Gaikwad
    Tanaji Gaikwad
    A. As Per BS EN 13445-3 B. As Per ASME Section VIII C. As Per CODAP D. PD 5500 E. AD 2000-Merkblatter F. General See Also Bentley AutoPIPE Vessel Support Solutions & FAQ's
    • 3 months ago
    • AutoPIPE
    • AutoPIPE Wiki
  • Item Type If value = "value"

    Mike Madrid
    Mike Madrid
    I am attempting to calculate an objects cost in ORD 10.10.21.04. This is also the case with MicroStation CE R17. iif(this.Unit = "Ton", System.Math.Round(this.Weight * this.Material_Cost_per_unit,1), "Nada")) Unit [text] & Material_Cost_per_unit…
    • Answered
    • over 1 year ago
    • MicroStation
    • MicroStation Forum
  • Unable to converge after conversion from PLAXIS 3D 2018 to PLAXIS 3D CE V22

    Aaron BUENAVENTURA
    Aaron BUENAVENTURA
    Hi all, I'm currently doing a project on tunneling and wanted to use the model from the previous project for it. However, the previous project used PLAXIS 3D 2018 and we recently upgraded to PLAXIS 3D CE V22. The warnings that appeared when the file…
    • over 1 year ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Forum
  • how can we check the sewergems calculation mannaully only for one pipe?

    Abhishek Verma
    Abhishek Verma
    iam calculating by manning Equation and continuity equation but not geting the exact velocity. variation in answer by 20 to 50 % between mannaul calculation and sewergems calculation.
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Forum
  • 17. Help understanding the changes to the sustained and occasional stresses from ASME B31.1 2018 to 2020?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Calculations Date Logged & Current Version July 2022 12.08.01.010 Problem: Help understanding the changes to the sustained and occasional stresses from…
    • over 1 year ago
    • AutoPIPE
    • AutoPIPE Wiki
  • Q. What values to use for B31J reducer R2, L2, and Cone angle in AutoPIPE?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Modeling Date Logged & Current Version June 2022 12.08.00.063 Problem: What values to use for B31J reducer R2, L2, and Cone angle in AutoPIPE? Solution…
    • 8 months ago
    • AutoPIPE
    • AutoPIPE Wiki
  • ASME B31J Code Calculation Issues

    Mike Dattilio
    Mike Dattilio
    Note: Please see the following AutoPIPE help section: Help > Contents> Contents Tab> Reference Information> Code Compliance Calculations> select a piping code to see the calculations performed by AutoPIPE. Comments, Questions, and Answers about ASME…
    • 8 months ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 00. How to calculate ASME B31.3 2010 Allowables in AutoPIPE?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Calculations Date Logged & Current Version June 2022 12.08.00.063 Problem: How to calculate ASME B31.3 2010 Allowables in AutoPIPE? Solution: ASME B31…
    • over 1 year ago
    • AutoPIPE
    • AutoPIPE Wiki
>